Cardiac computed tomography angiography with and without bolus tracking methods in infants with congenital heart disease

被引:1
作者
Yoshiura, Takayuki [1 ,2 ]
Masuda, Takanori [3 ]
Tahara, Masahiro [4 ]
Kobayashi, Yukie [2 ]
Kikuhara, Yukari [2 ]
Ishibashi, Toru [2 ]
Nonaka, Haruki [2 ]
Oku, Takayuki [2 ]
Sato, Tomoyasu [2 ]
Funama, Yoshinori [5 ]
机构
[1] Kumamoto Univ, Grad Sch Hlth Sci, 4-24-1 Kuhonji, Kumamoto 8620976, Japan
[2] Tsuchiya Gen Hosp, Dept Med Technol, 3-30 Nakajima Cho, Hiroshima 7308655, Japan
[3] Kawasaki Univ Med Welf, Fac Hlth Sci & Technol, Dept Radiol Technol, 288 Matsushima, Kurashiki, Okayama 7010193, Japan
[4] Hiroshima Cent St Childrens Clin, 7-1 Mikawa Cho, Hiroshima 7300029, Japan
[5] Kumamoto Univ, Fac Life Sci, Dept Med Radiat Sci, 4-24-1 Kuhonji, Kumamoto 8620976, Japan
关键词
RADIATION-EXPOSURE; PEDIATRIC-PATIENTS; CT ANGIOGRAPHY; TETRALOGY; PREVALENCE; CHILDREN; SOCIETY; FALLOT; TRENDS; CANCER;
D O I
10.1093/rpd/ncad295
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The study investigated radiation dose, vascular computed tomography (CT) enhancement and image quality of cardiac computed tomography angiography (CCTA) with and without bolus tracking (BT) methods in infants with congenital heart disease (CHD). The volume CT dose index (CTDIvol) and dose length product (DLP) were recorded for all CT scans, and the effective dose was obtained using a conversion factors. The CT number for the ascending aorta (AO) and pulmonary artery (PA), image noise of muscle tissue and contrast-to-noise ratio (CNR) were measured and calculated. The median values in the groups with and without BT were 2.20 mGy versus 0.44 mGy for CTDIvol, 8.10 mGy<middle dot>cm versus 6.20 mGy<middle dot>cm for DLP, and 0.66 mSv versus 0.51 mSv for effective dose (p < 0.001). There were no statistical differences in vascular CT enhancement, image noise, and CNR. CCTA without BT methods can reduce the radiation dose while maintaining vascular CT enhancement and image quality compared to CCTA with BT methods.
引用
收藏
页码:251 / 258
页数:8
相关论文
共 32 条
  • [1] Role of Multidetector CT in Assessment of Repaired Tetralogy of Fallot
    Ahmed, Sameer
    Johnson, Pamela Tecce
    Fishman, Elliot K.
    Zimmerman, Stefan Loy
    [J]. RADIOGRAPHICS, 2013, 33 (04) : 1023 - 1036
  • [2] Balzer David, 2019, Methodist Debakey Cardiovasc J, V15, P122, DOI 10.14797/mdcj-15-2-122
  • [3] Cardiovascular imaging in pediatric patients using dual source CT
    Booij, Ronald
    Dijkshoorn, Marcel L.
    van Straten, Marcel
    du Plessis, Frederik A.
    Budde, Ricardo P. J.
    Moelker, Adriaan
    Krestin, Gabriel P.
    Ouhlous, Mohamed
    [J]. JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2016, 10 (01) : 13 - 21
  • [4] Estimated risks of radiation-induced fatal cancer from pediatric CT
    Brenner, DJ
    Elliston, CD
    Hall, EJ
    Berdon, WE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) : 289 - 296
  • [5] Adolescent Kawasaki disease: usefulness of 64-slice CT coronary angiography for follow-up investigation
    Carbone, Iacopo
    Cannata, David
    Algeri, Emanuela
    Galea, Nicola
    Napoli, Alessandro
    De Zorzi, Andrea
    Bosco, Giovanna
    D'Agostino, Rita
    Menezes, Leon
    Catalano, Carlo
    Passariello, Roberto
    Francone, Marco
    [J]. PEDIATRIC RADIOLOGY, 2011, 41 (09) : 1165 - 1173
  • [6] Tetralogy of Fallot General Principles of Management
    Downing, Tacy E.
    Kim, Yuli Y.
    [J]. CARDIOLOGY CLINICS, 2015, 33 (04) : 531 - +
  • [7] CT of congenital heart disease: Normal anatomy and typical pathologic conditions
    Goo, HW
    Park, IS
    Ko, JK
    Kim, YH
    Seo, DM
    Yun, TJ
    Park, JJ
    Yoon, CH
    [J]. RADIOGRAPHICS, 2003, 23 : S147 - S165
  • [8] Computed tomography for the diagnosis of congenital heart disease in pediatric and adult patients
    Goo, HW
    Park, IS
    Ko, JK
    Kim, YH
    Seo, DM
    Park, JJ
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2005, 21 (2-3) : 347 - 365
  • [9] Changes in Right Ventricular Volume, Volume Load, and Function Measured with Cardiac Computed Tomography over the Entire Time Course of Tetralogy of Fallot
    Goo, Hyun Woo
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2019, 20 (06) : 956 - 966
  • [10] Current trends in cardiac CT in children
    Goo, Hyun Woo
    [J]. ACTA RADIOLOGICA, 2013, 54 (09) : 1055 - 1062