Influence of Kennedy class and number of implants on the accuracy of dynamic implant navigation: An in vitro study using an X-ray free evaluation methodology
被引:5
作者:
Rutkunas, Vygandas
[1
]
Gendviliene, Ieva
[1
]
Auskalnis, Liudas
[1
]
Mangano, Francesco
[2
]
Zlatev, Stefan
[3
]
Ivanova, Vasilena
[4
]
Mijiritsky, Eitan
[5
]
Borusevicius, Rokas
[1
]
机构:
[1] Vilnius Univ, Inst Odontol, Fac Med, LT-03101 Vilnius, Lithuania
[2] Univ Hong Kong, Fac Dent, Restorat Dent Sci, Hong Kong, Peoples R China
[3] Med Univ Plovdiv, CAD CAM Ctr Dent Med Res Inst, Plovdiv 4000, Bulgaria
[4] Med Univ Plovdiv, Fac Dent Med, Oral Surg Dept, Plovdiv 4000, Bulgaria
[5] Tel Aviv Univ, Sackler Fac Med, Tel Aviv Sourasky Med Ctr, Dept Otolaryngol,Head & Neck Maxillofacial Surg, IL-699350 Tel Aviv, Israel
关键词:
Dental implants;
Dynamic navigation;
Implant guide;
CBCT;
SURGICAL GUIDE;
PLACEMENT;
SURGERY;
SYSTEM;
D O I:
10.1016/j.jdent.2023.104679
中图分类号:
R78 [口腔科学];
学科分类号:
1003 ;
摘要:
Objectives: The aim of this in vitro study was to evaluate the accuracy of fully guided dynamic implant navigation surgery in Kennedy I, II, and III class dental arch defects with two different implant designs, using an X-ray free evaluation method. Methods: Polyurethane resin maxillary models simulated posterior edentulous defects. Four cone beam computed tomography (CBCT) scans and four intraoral (IOS) scans were obtained for each model and a digital wax-up with the correct implant positions was made. The accuracy of implant positions was evaluated using an IOS-based Xray-free method (3Shape). Four deviation characteristics were evaluated: insertion point, depth deviation, horizontal and angle deviation. Results: The insertion point deviation measures ranged from 0.19 mm to 1.71 mm. Depth (s) and (u) deviations ranged from -1.47 mm to 0.74 mm and from 0.02 mm to 1.47 mm, respectively. Horizontal deviation ranged from 0.09 mm to 1.37 mm. Conclusions: There is a tendency of a decreasing insertion point deviation for an increasing number and distribution area of the teeth (increasing Kennedy class number). Kennedy class II and distal implant position had the most influence for the higher deviations. Clinical significance: Dynamic implant guidance provides accurate spacing, angulation, depth and position of the implants. It is important to understand how the number of missing teeth and implant design could influence the accuracy of dynamic implant navigation. Thus, it is important to evaluate factors influencing the accuracy of dynamic systems by using a X-ray-free post-operative method and to overcome the limitations of providing multiple CBCT scans.