Sinus node dysfunction during transcatheter assessment and stent correction of sinus venosus atrial septal defects

被引:3
作者
Sandoval, Juan Pablo [1 ]
Rosenthal, Eric [2 ]
Arias, Eduardo [1 ]
Garcia-Montes, Jose A. [1 ]
Rodriguez-Zanella, Hugo [1 ]
Zabal, Carlos [1 ]
Kabir, Saleha [2 ]
Yong, San Fui [2 ]
Jones, Matthew [2 ]
Qureshi, Shakeel [2 ]
机构
[1] Ignacio Chavez Natl Inst Cardiol, Imaging & Intervent Congenital & Struct Heart Dis, Mexico City, Mexico
[2] Guys & St Thomas Hosp Trust, Evelina London Childrens Hosp, Paediat & Adult Congenital Heart Dis, London, England
关键词
covered stent; pacemaker; sinus node dysfunction; sinus venous ASD;
D O I
10.1002/ccd.30790
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Covered stent correction of a superior sinus venosus atrial septal defect is increasingly performed as an alternative to surgical repair. While sinus node dysfunction requiring pacemaker implantation may be required after surgical repair, this has not been previously reported after covered stent implantation. We reviewed the experience in two interventional centers. Balloon inflation in the superior vena cava was used to confirm the anomalous pulmonary vein drainage would be unobstructed after stent implantation. During balloon testing in 62 consecutive patients, we assessed gradients across the pulmonary vein to left atrium while monitoring the rhythm. We observed the outcomes after covered stent correction in 51 patients. In a single patient, significant bradycardia and pauses developed on repeat balloon testing and the procedure was abandoned without stent implantation. In another patient, there was no sign of sinus node dysfunction during balloon testing but several hours after stent implantation, the patient became symptomatic from sinus bradycardia and pauses and had a pacemaker implanted 3 days later. Over a year later there are some signs of improvement in sinus node function. While sinus node dysfunction has not been described previously during balloon testing or after stent implantation, this report demonstrates for the first time that it may occur. Larger registries are therefore required to monitor for this uncommon complication.
引用
收藏
页码:683 / 687
页数:5
相关论文
共 50 条
  • [1] Correction of sinus venosus atrial septal defects with the 10 zig covered Cheatham-platinum stent - An international registry
    Rosenthal, Eric
    Qureshi, Shakeel A.
    Jones, Matthew
    Butera, Gianfranco
    Sivakumar, Kothandam
    Boudjemline, Younes
    Hijazi, Ziyad M.
    Almaskary, Salim
    Ponder, Reid D.
    Salem, Morris M.
    Walsh, Kevin
    Kenny, Damien
    Hascoet, Sebastien
    Berman, Darren P.
    Thomson, John
    Vettukattil, Joseph J.
    Zahn, Evan M.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2021, 98 (01) : 128 - 136
  • [2] How to do it? Transcatheter correction of superior sinus venosus defects
    Sivakumar, Kothandam
    ANNALS OF PEDIATRIC CARDIOLOGY, 2022, 15 (02) : 169 - 174
  • [3] Endoleak in covered CP stent causes procedural failure during transcatheter closure of sinus venosus defects
    Qureshi, Farheen
    Sivakumar, Kothandam
    Sagar, Pramod
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2024, 103 (02) : 317 - 321
  • [4] Sinus Node Dysfunction, Atrial Arrhythmias, and the Sinus Node Microcirculation
    Fellner, Susan K.
    CLINICAL MEDICINE INSIGHTS-CASE REPORTS, 2022, 15
  • [5] Sinus Node Dysfunction, Atrial Arrhythmias, and the Sinus Node Microcirculation
    Fellner, Susan K.
    CLINICAL MEDICINE INSIGHTS-CASE REPORTS, 2022, 15
  • [6] CT angiography for planning of percutaneous closure of a sinus venosus atrial septal defect using a covered stent
    Gertz, Zachary M.
    Strife, Brian J.
    Shah, Pranav R.
    Parris, Kendall
    Grizzard, John D.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2018, 12 (02) : 174 - 175
  • [7] Novel technique for transcatheter closure of sinus venosus atrial septal defect: The temporary suture-holding technique
    Hejazi, Yahia
    Hijazi, Ziyad M.
    Al Saloos, Hesham
    Ibrahim, Haytham
    Mann, Gurdeep S.
    Boudjemline, Younes
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2022, 100 (06) : 1068 - 1077
  • [8] The wedding cake solution: A percutaneous correction of a form fruste superior sinus venosus atrial septal defect
    Crystal, Matthew A.
    Vincent, Julie A.
    Gray, William A.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 86 (07) : 1204 - 1210
  • [9] Sinus venosus atrial septal defect: a rare cause of misplacement of pacemaker leads
    Bodian, Malick
    Aw, Fatou
    Ndiaye, Mouhamadou Bamba
    Kane, Adama
    Jobe, Modou
    Tabane, Alioune
    Mbaye, Alassane
    Sarr, Simon Antoine
    Diao, Maboury
    Sarr, Moustapha
    Ba, Serigne Abdou
    INTERNATIONAL MEDICAL CASE REPORTS JOURNAL, 2013, 6 : 29 - 32
  • [10] Prevalence and predictors of atrial arrhythmias in patients with sinus node dysfunction and atrial pacing
    Abdallah Bukari
    Eisha Wali
    Amrish Deshmukh
    Zaid Aziz
    Michael Broman
    Andrew Beaser
    Gaurav Upadhyay
    Hemal Nayak
    Roderick Tung
    Cevher Ozcan
    Journal of Interventional Cardiac Electrophysiology, 2018, 53 : 365 - 371