Comparative study of neointimal coverage between titanium-nitric oxide-coated and everolimus-eluting stents in acute coronary syndromes

被引:0
|
作者
Sia, Jussi [1 ]
Nammas, Wail
Collet, Carlos [3 ]
De Bruyne, Bernard [3 ]
Karjalainen, Pasi P. [2 ,4 ]
机构
[1] Kokkola Cent Hosp, Dept Cardiol, Kokkola, Finland
[2] Satakunta Cent Hosp, Heart Ctr, Pori, Finland
[3] Cardiovasc Ctr Aalst, OLV Clin, Aalst, Belgium
[4] Helsinki Univ Hosp, Heart & Lung Ctr, Helsinki, Finland
来源
REVISTA ESPANOLA DE CARDIOLOGIA | 2023年 / 76卷 / 03期
关键词
Optical coherence tomography; Acute coronary syndrome; Neointimal strut coverage; Stent malapposition; Neointimal hyperplasia; OPTICAL COHERENCE TOMOGRAPHY; INTRAVASCULAR ULTRASOUND; BIOACTIVE STENTS; STRUT COVERAGE; THROMBOSIS; SAFETY; IMPLANTATION; APPOSITION; EFFICACY; INSIGHTS;
D O I
10.1016/j.recesp.2022.05.011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction and objectives: To evaluate by optical coherence tomography neointimal healing response after implantation of cobalt-chromium-based titanium-nitride-oxide-coated (TiNO) stents and platinum-chromium-based biodegradable-polymer-coated everolimus-eluting stents (EES) in patients with acute coronary syndrome. Methods: Patients were randomized (1:1) to receive either a TiNO-stent or EES. Optical coherence tomography images were obtained at 30-day (cohort A, n = 52) and 6-month (cohort B, n = 30) follow-up. The primary endpoint was the percentage of uncovered struts per patient. Results: In cohort A, the percentage of uncovered struts was lower with TiNO-stents vs EES (3.2% vs 19.6%, P < .001). The percentage of malapposed struts was 0.4% in the TiNO-group and 2.1% in the EES group (P < .001). In cohort B, the percentage of uncovered struts was also lower with TiNO-stents (0.0% vs 8.7% (P < .001). The percentage of malapposed struts was 0% in the TiNO-stent group and 0.3% in the EES group (P = .008). None of the patients had repeat revascularization during the 6 months of follow-up. Conclusions: Following percutaneous intervention for acute coronary syndrome, TiNO stent implanta-tion was associated with a lower percentage of uncovered and malapposed struts per patient, compared with EES, at early and mid-term follow-up. This study is registered under ClinicalTrials.gov, with number NCT02464397. (c) 2022 Sociedad Espanola de Cardiologia. Published by Elsevier Espana, S.L.U. All rights reserved.
引用
收藏
页码:150 / 156
页数:7
相关论文
共 33 条
  • [31] Different patterns of neointimal coverage between acute coronary syndrome and stable angina after various types of drug-eluting stents implantation; 9-month follow-up optical coherence tomography study
    Kim, Jung-Sun
    Fan, Chunyu
    Choi, Donghoon
    Jang, Ik-Kyung
    Lee, Jung Myung
    Kim, Tae Hoon
    Park, Sang Min
    Paik, Sung Il
    Ko, Young-Guk
    Hong, Myeong-Ki
    Jang, Yangsoo
    Chung, Namsik
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 146 (03) : 341 - 346
  • [32] Two-year follow-up after percutaneous coronary intervention with titanium-nitride-oxide-coated stents versus paclitaxel-eluting stents in acute myocardial infarction
    Karjalainen, Pasi P.
    Ylitalo, Antti
    Niemela, Matti
    Kervinen, Kari
    Makikallio, Timo
    Pietila, Mikko
    Sia, Jussi
    Tuomainen, Petri
    Nyman, Kai
    Airaksinen, K. E. Juhani
    ANNALS OF MEDICINE, 2009, 41 (08) : 599 - 607
  • [33] A Propensity Score-Matched Comparison of Midterm Outcomes Between Drug-Coated Balloons and Drug-Eluting Stents for Patients with Acute Coronary Syndrome A Single-Center Study
    Mizutani, Yukiko
    Ishikawa, Tetsuya
    Nakamura, Hidehiko
    Yamada, Kota
    Shimura, Masatoshi
    Kondo, Yuki
    Ukaji, Tomoaki
    Aoki, Hideyuki
    Hisauchi, Itaru
    Itabashi, Yuji
    Nakahara, Shiro
    Taguchi, Isao
    INTERNATIONAL HEART JOURNAL, 2022, 63 (02) : 217 - 225