Comparative study of neointimal coverage between titanium-nitric oxide-coated and everolimus-eluting stents in acute coronary syndromes

被引:0
|
作者
Sia, Jussi [1 ]
Nammas, Wail
Collet, Carlos [3 ]
De Bruyne, Bernard [3 ]
Karjalainen, Pasi P. [2 ,4 ]
机构
[1] Kokkola Cent Hosp, Dept Cardiol, Kokkola, Finland
[2] Satakunta Cent Hosp, Heart Ctr, Pori, Finland
[3] Cardiovasc Ctr Aalst, OLV Clin, Aalst, Belgium
[4] Helsinki Univ Hosp, Heart & Lung Ctr, Helsinki, Finland
来源
REVISTA ESPANOLA DE CARDIOLOGIA | 2023年 / 76卷 / 03期
关键词
Optical coherence tomography; Acute coronary syndrome; Neointimal strut coverage; Stent malapposition; Neointimal hyperplasia; OPTICAL COHERENCE TOMOGRAPHY; INTRAVASCULAR ULTRASOUND; BIOACTIVE STENTS; STRUT COVERAGE; THROMBOSIS; SAFETY; IMPLANTATION; APPOSITION; EFFICACY; INSIGHTS;
D O I
10.1016/j.recesp.2022.05.011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction and objectives: To evaluate by optical coherence tomography neointimal healing response after implantation of cobalt-chromium-based titanium-nitride-oxide-coated (TiNO) stents and platinum-chromium-based biodegradable-polymer-coated everolimus-eluting stents (EES) in patients with acute coronary syndrome. Methods: Patients were randomized (1:1) to receive either a TiNO-stent or EES. Optical coherence tomography images were obtained at 30-day (cohort A, n = 52) and 6-month (cohort B, n = 30) follow-up. The primary endpoint was the percentage of uncovered struts per patient. Results: In cohort A, the percentage of uncovered struts was lower with TiNO-stents vs EES (3.2% vs 19.6%, P < .001). The percentage of malapposed struts was 0.4% in the TiNO-group and 2.1% in the EES group (P < .001). In cohort B, the percentage of uncovered struts was also lower with TiNO-stents (0.0% vs 8.7% (P < .001). The percentage of malapposed struts was 0% in the TiNO-stent group and 0.3% in the EES group (P = .008). None of the patients had repeat revascularization during the 6 months of follow-up. Conclusions: Following percutaneous intervention for acute coronary syndrome, TiNO stent implanta-tion was associated with a lower percentage of uncovered and malapposed struts per patient, compared with EES, at early and mid-term follow-up. This study is registered under ClinicalTrials.gov, with number NCT02464397. (c) 2022 Sociedad Espanola de Cardiologia. Published by Elsevier Espana, S.L.U. All rights reserved.
引用
收藏
页码:150 / 156
页数:7
相关论文
共 33 条
  • [21] Neointimal coverage and late apposition of everolimus-eluting bioresorbable scaffolds implanted in the acute phase of myocardial infarction: OCT data from the PRAGUE-19 study
    Tousek, Petr
    Kocka, Viktor
    Maly, Martin
    Lisa, Libor
    Budesinsky, Tomas
    Widimsky, Petr
    HEART AND VESSELS, 2016, 31 (06) : 841 - 845
  • [22] Titanium-nitride-oxide-coated vs. drug-eluting stents in acute coronary syndromes: an individual patient data meta-analysis
    Mahendiran, Thabo
    Bouisset, Frederic
    Tonino, Pim
    Pijls, Nico H. J.
    Sia, Jussi
    Kervinen, Kari
    Rivero-Crespo, Fernando
    Juni, Peter
    da Costa, Bruno Roza
    Collet, Carlos
    Mizukami, Takuya
    Karjalainen, Pasi
    De Bruyne, Bernard
    EUROPEAN HEART JOURNAL, 2025,
  • [23] Stent strut coverage of titanium-nitride-oxide coated stent compared to paclitaxel-eluting stent in acute myocardial infarction: TITAX-OCT study
    Lehtinen, Tuomas
    Airaksinen, K. E. Juhani
    Ylitalo, Antti
    Karjalainen, Pasi P.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (08) : 1859 - 1866
  • [24] A prospective randomised study using optical coherence tomography to assess endothelial coverage and neointimal proliferation at 6-months after implantation of a coronary everolimus-eluting stent compared with a bare metal stent postdilated with a paclitaxel-eluting balloon (OCTOPUS trial): rationale, design and methods
    Poerner, Tudor C.
    Otto, Sylvia
    Gassdorf, Johannes
    Janiak, Florian
    Danzer, Constance
    Ferrari, Markus
    Figulla, Hans R.
    EUROINTERVENTION, 2011, 7 : K93 - K99
  • [25] Stent Coverage and Neointimal Proliferation in Bare Metal Stents Postdilated With a Paclitaxel-Eluting Balloon Versus Everolimus-Eluting Stents Prospective Randomized Study Using Optical Coherence Tomography at 6-Month Follow-Up
    Poerner, Tudor C.
    Otto, Sylvia
    Gassdorf, Johannes
    Nitsche, Kristina
    Janiak, Florian
    Scheller, Bruno
    Goebel, Bjoern
    Jung, Christian
    Figulla, Hans R.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (06) : 760 - U53
  • [26] Long-term outcomes of titanium-nitride-oxide coated stents and drug-eluting stents in acute coronary syndrome: A systematic review and meta-analysis
    Fahim, Muhammad Ahmed Ali
    Salman, Afia
    Khan, Hira Anas
    Hasan, Syed Muhammad
    Bhojani, Muskan Fatima
    Aslam, Sarah
    Ul Haq, Amna Zia
    Bejugam, Vishal Reddy
    Nasir, Beena Muntaha
    Gul, Wajiha
    Moeed, Abdul
    Abdalla, Abdelrahman S.
    Majid, Muhammad
    Asghar, Muhammad Sohaib
    Al Hasibuzzaman, Md
    WORLD JOURNAL OF CARDIOLOGY, 2024, 16 (05): : 293 - 305
  • [27] Outcome of ST-elevation myocardial infarction versus non-ST-elevation acute coronary syndrome treated with titanium-nitride-oxide-coated versus everolimus-eluting stents: insights from the BASE-ACS trial
    Romppanen, H.
    Nammas, W.
    Kervinen, K.
    Mikkelsson, J.
    Pietila, M.
    Lalmand, J.
    Rivero-Crespo, F.
    Pentikainen, M.
    Tedjokusumo, P.
    Karjalainen, P. P.
    MINERVA CARDIOANGIOLOGICA, 2013, 61 (02): : 201 - 209
  • [28] Different vascular healing process between bioabsorbable polymer-coated everolimus-eluting stents versus bioresorbable vascular scaffolds via optical coherence tomography and coronary angioscopy (the ENHANCE study: ENdothelial Healing Assessment with Novel Coronary tEchnology)
    Wan Azman Wan Ahmad
    Takaharu Nakayoshi
    Ahmad Syadi Mahmood Zuhdi
    Muhammad Dzafir Ismail
    Imran Zainal Abidin
    Yasushi Ino
    Takashi Kubo
    Takashi Akasaka
    Yoshihiro Fukumoto
    Takafumi Ueno
    Heart and Vessels, 2020, 35 : 463 - 473
  • [29] Neointimal coverage and stent strut apposition six months after implantation of a paclitaxel eluting stent in acute coronary syndromes: An optical coherence tomography study
    Davlouros, Periklis A.
    Nikokiris, George
    Karantalis, Vasileios
    Mavronasiou, Eleni
    Xanthopoulou, Ioanna
    Damelou, Anastasia
    Tsigkas, Grigorios
    Alexopoulos, Dimitrios
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 151 (02) : 155 - 159
  • [30] Two-year clinical outcomes of zotarolimus- and everolimus-eluting durable-polymer-coated stents versus biolimus-eluting biodegradable-polymer-coated stent in patients with acute myocardial infarction with dyslipidemia after percutaneous coronary intervention: data from the KAMIR
    Kim, Yong Hoon
    Her, Ae-Young
    Jeong, Myung Ho
    Kim, Byeong-Keuk
    Hong, Sung-Jin
    Shin, Dong-Ho
    Kim, Jung-Sun
    Ko, Young-Guk
    Choi, Donghoon
    Hong, Myeong-Ki
    Jang, Yangsoo
    HEART AND VESSELS, 2019, 34 (02) : 237 - 250