The Acoustic Center of a Measuring Hydrophone

被引:0
作者
Isaev, A. E. [1 ]
Khatamtaev, B. I. [1 ]
机构
[1] All Russia Res Inst Phys Tech & Radio Engn Measure, Mendeleyevsk 141570, Russia
关键词
hydrophone phase calibration; acoustic center; reciprocity method; CALIBRATION; FREQUENCY; RECEIVER; FIELD;
D O I
10.1134/S1063771022060057
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Various approaches to the formulation of the definition of an acoustic center of a transducer and the problems arising when using them for experimental determination of the acoustic-center position are considered. The reasons for which the formulation and the corresponding method for determining the position of the acoustic center of a microphone are not suitable for a hydrophone are discussed. An experiment is described that demonstrates the proposed method for experimentally determining the position of the acoustic center of a hydrophone during its phase calibration by the reciprocity method.
引用
收藏
页码:93 / 101
页数:9
相关论文
共 50 条
  • [41] Correction for Hydrophone Spatial Averaging Artifacts for Circular Sources
    Wear, Keith A.
    Shah, Anant
    Baker, Christian
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (12) : 2674 - 2691
  • [42] Measuring Consciousness
    Sen, Siddhartha
    JOURNAL OF CONSCIOUSNESS STUDIES, 2018, 25 (9-10) : 228 - 251
  • [43] Absorption Enhancement of Coated Absorbing Aerosols: Validation of the Photo-Acoustic Technique for Measuring the Enhancement
    Lack, Daniel A.
    Cappa, Christopher D.
    Cross, Eben S.
    Massoli, Paola
    Ahern, Adam T.
    Davidovits, Paul
    Onasch, Timothy B.
    AEROSOL SCIENCE AND TECHNOLOGY, 2009, 43 (10) : 1006 - 1012
  • [44] Calibration of an acoustic system for measuring 2-D temperature distribution around hydrothermal vents
    Fan, Wei
    Chen, Chen-Tung Arthur
    Chen, Ying
    ULTRASONICS, 2013, 53 (04) : 897 - 906
  • [45] A Reciprocity-Based Method to Determine Hydrophone Complex Sensitivity and Tested at Frequencies from 1 to 7 MHz
    de Oliveira, Everande Gobira
    Costa-Felix, Rodrigo P. B.
    Machado, Joao Carlos
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 1964 - 1967
  • [46] Automatic Alignment System Based on Center Point Recognition of Analog Measuring Instruments Dial
    Wang Qi
    Tang Xiling
    Ding Cheng
    He Yao
    Fang Yanjun
    39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013), 2013, : 5532 - 5536
  • [47] Acoustic velocity measurements in resonators of thermoacoustic systems using hot-wire anemometry
    Jerbi, F. Jebali
    Huelsz, G.
    Kouidri, S.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2013, 32 : 41 - 50
  • [48] PROGRESS OF THE DEVELOPMENT AND CALIBRATION OF NEEDLE-TYPE ULTRASONIC HYDROPHONE
    Wu, Hong
    He, Long-biao
    Zhou, Jing-lin
    Yang, Ping
    2013 SYMPOSIUM ON PIEZOELECTRICITY, ACOUSTIC WAVES AND DEVICE APPLICATIONS (SPAWDA), 2013, : 249 - 252
  • [49] Hydrophone Spatial Averaging Correction for High-Frequency Arrays
    Wear, Keith
    Shah, Anant
    2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [50] Investigation of the repeatability and reproducibility of hydrophone measurements of medical ultrasound fields
    Martin, Eleanor
    Treeby, Bradley
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2019, 145 (03) : 1270 - 1282