Solid-state ion-selective electrodes for the first potentiometric determination of the anti-COVID 19 drug Remdesivir in human plasma; A comparative study

被引:14
作者
El Azab, Noha F. [1 ]
Ahmed, Neven [2 ]
机构
[1] Ain Shams Univ, Fac Pharm, Pharmaceut Analyt Chem Dept, Org African Unity St, Cairo 11566, Egypt
[2] Egyptian Drug Author, Giza, Egypt
关键词
Remdesivir; Graphene; Polyaniline nanoparticles; Ion selective electrode; Plasma; G; PANI nanocomposite; POLYANILINE NANOPARTICLES; EXFOLIATED GRAPHITE; CARBON NANOTUBES; SENSORS; GRAPHENE; LAYER; COEFFICIENTS; COMPOSITES; TRANSDUCER;
D O I
10.1016/j.microc.2023.108658
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Establishing sensitive and targeted analytical methodologies for drug identification in biological fluids as well as screening of treatments that can counteract the most severe COVID-19 infection-related side effects are of utmost importance. Here, first attempts have been made for determination of the anti-COVID drug Remdesivir (RDS) in human plasma using four potentiometric sensors. Calixarene-8 (CX8) was used as an ionophore applied to the first electrode (Sensor I). The second had a layer of dispersed graphene nanocomposite coating (Sensor II). (Sensor III) was fabricated using nanoparticles of polyaniline (PANI) as ion-to-electron transducer. A reverse -phase polymerization using polyvinylpyrrolidone (PVP) was employed to create a graphene-polyaniline (G/ PANI) nanocomposite electrode (Sensor IV). Surface morphology was confirmed by Scanning Electron Micro-scope (SEM). UV absorption spectra and Fourier Transform Ion Spectrophotometry (FTIR) also supported their structural characterization. The impact of graphene and polyaniline integration on the functionality and dura-bility of the manufactured sensors was examined using the water layer test and signal drift. In the ranges of concentration of 10-7 to 10-2 mol/L and 10-7 to 10-3, sensors II & IV exhibited linear responses; respectively while sensors I & III displayed linearity within 10-6 to 10-2 mol/L. The target drug was easily detectable using LOD down to 100 nmol/L. The developed sensors satisfactorily offered sensitive, stable, selective and accurate estimate of Remdesivir (RDS) in its pharmaceutical formulation as well as spiked human plasma with recoveries ranging from 91.02 to 95.76 % with average standard deviations less than 1.85. The suggested procedure was approved in accordance with ICH recommendations.
引用
收藏
页数:10
相关论文
共 52 条
[1]   Design of a stable solid-contact ion-selective electrode based on polyaniline nanoparticles as ion-to-electron transducer for application in process analytical technology as a real-time analyzer [J].
Abd El-Rahman, Mohamed K. ;
Rezk, Mamdouh R. ;
Mahmoud, Amr M. ;
Elghobashy, Mohamed R. .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 208 :14-21
[2]   Piribedil-selective electrodes based on Bi(III)-iodide and Hg(II)-iodide complexes [J].
Abdel-Gawad, FM ;
Issa, YM ;
Hassouna, MEM ;
Hussien, EM .
MICROCHIMICA ACTA, 2003, 141 (1-2) :7-13
[3]   Novel potentiometric sensors for the determination of the dinotefuran insecticide residue levels in cucumber and soil samples [J].
Abdel-Ghany, Maha F. ;
Hussein, Lobna A. ;
El Azab, Noha F. .
TALANTA, 2017, 164 :518-528
[4]   Few-layer graphene and polyaniline composite as ion-to-electron transducer in silicone rubber solid-contact ion-selective electrodes [J].
Boeva, Zhanna A. ;
Lindfors, Tom .
SENSORS AND ACTUATORS B-CHEMICAL, 2016, 224 :624-631
[5]   Dispersible composites of exfoliated graphite and polyaniline with improved electrochemical behaviour for solid-state chemical sensor applications [J].
Boeva, Zhanna A. ;
Milakin, Konstantin A. ;
Pesonen, Markus ;
Ozerin, Aleksander N. ;
Sergeyev, Vladimir G. ;
Lindfors, Tom .
RSC ADVANCES, 2014, 4 (86) :46340-46350
[6]   A comparative study of HPLC and UV spectrophotometric methods for remdesivir quantification in pharmaceutical formulations [J].
Bulduk, Ibrahim ;
Akbel, Erten .
JOURNAL OF TAIBAH UNIVERSITY FOR SCIENCE, 2021, 15 (01) :507-513
[7]   In situ one-pot preparation of reduced graphene oxide/polyaniline composite for high-performance electrochemical capacitors [J].
Chen, Nali ;
Ren, Yapeng ;
Kong, Peipei ;
Tan, Lin ;
Feng, Huixia ;
Luo, Yongchun .
APPLIED SURFACE SCIENCE, 2017, 392 :71-79
[8]  
Chera A., 2022, DISCOVERIES, V10
[9]  
E.-P. National Center for Biotechnology Information, PUBCHEM COMP SUMM CI
[10]   Point-of-care diagnostics for therapeutic monitoring of levofloxacin in human plasma utilizing electrochemical sensor mussel-inspired molecularly imprinted copolymer [J].
El Azab, Noha F. ;
Mahmoud, Amr M. ;
Trabik, Yossra A. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2022, 918