Exploring Analytical Quality by Design (AQbD) Enabled RP-HPLC Method for Carvedilol

被引:0
|
作者
Randive, Krantisinha Hanumant [1 ,2 ]
Maste, Meenaxi Maruti [1 ,4 ]
Kempwade, Amolkumar Ashok [3 ]
机构
[1] KLE Acad Higher Educ & Res, KLE Coll Pharm, Dept Pharmaceut Chem, Belagavi, Karnataka, India
[2] KLESs Coll Pharm, Dept Pharmaceut Chem, Nipani, Karnataka, India
[3] KLESs Coll Pharm, Dept Pharmaceut, Nipani, Karnataka, India
[4] KLE Acad Higher Educ & Res, KLE Coll Pharm, Dept Pharmaceut Chem, Belagavi 590010, Karnataka, India
关键词
Analytical Quality by Design; Carvedilol; RP-HPLC; Box-Behnken design; Taguchi; Design; OPTIMIZATION; VALIDATION;
D O I
10.5530/ijper.58.2.73
中图分类号
G40 [教育学];
学科分类号
040101 ; 120403 ;
摘要
Background: Carvedilol (CDL) is a beta-blocker that helps to lower the risk of heart attack related mortality and is used to treat congestive heart failure and excessive blood pressure. Objectives: The present study deals with the development and validation of a reverse-phase high performance liquid chromatography method for rapid and reliable analysis of CDL by utilizing the Analytical Quality by Design (AQbD) approach. Materials and Methods: Critical Analytical Attributes (CAAs) were selected based on predefined Analytical Target Attributes (ATPs). Further screening of Critical Material Attributes (CMAs) and Critical Process Parameters (CPPs) having a significant impact on assigned CAAs was done by Taguchi Design. The optimized mobile phase consists of 0.1% Orthophosphoric Acid (OPA) and methanol in a ratio of 35:65% v/v. The flow rate was maintained at 1 mL/min, the column temperature was 30(o)C, and the analysis was carried out at 240 nm. Based on the results obtained, fine tuning of the CAAs was done by opting for the 32-Box-Behnken design. Results: The area under the curve was found to be linear within the studied range of 5-30 mu g/mL (R2=0.999). The retention time was found to be 4.18 min, with a sharp, well-defined peak. The percentage recovery of the drug during the accuracy study was found to be in the range between 97.06 and 99.29%. The detection and quantification limits were found to be 0.61 mu g/mL and 1.86 mu g/mL, respectively. Conclusion: The developed method was found to be precise with a RSD of <1%. The method can be effectively utilized for routine analysis of bulk drug and dosage forms in quality control labs.
引用
收藏
页码:651 / 660
页数:10
相关论文
共 50 条
  • [21] Estimation of Lamotrigine by RP-HPLC Method
    Kumar, D. Anantha
    Kumar, Ch Venkata
    Seetharamaiah, P.
    Rao, J. V. L. N. Seshagiri
    E-JOURNAL OF CHEMISTRY, 2010, 7 : S203 - S208
  • [22] ANALYTICAL METHOD DEVELOPMENT AND VALIDATION OF IVACAFTOR AND LUMACAFTOR BY RP-HPLC METHOD
    Sravanthi, B.
    Divya, M.
    INDO AMERICAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2016, 3 (08): : 900 - 904
  • [23] Stability Indicating Assay for the Determination of Bilastine in Bulk Drug and Method Development Validation by RP-HPLC Using Analytical Quality by Design Approaches
    Nayak, Anjali
    Alwin, R. Maria Danish
    Sangeetha, G.
    Sowmya, C. Y.
    Reddy, Yashwanth V.
    Dang, Raman
    INDIAN JOURNAL OF PHARMACEUTICAL EDUCATION AND RESEARCH, 2024, 58 (02) : s582 - s590
  • [24] A SIMPLE ISOCRATIC RP-HPLC METHOD FOR QUALITY CONTROL OF OSELTAMIVIR CAPSULES
    Ameti, Agim
    Slavkovska, Jasmina
    Starkoska, Katerina
    Arsova-Sarafinovska, Zorica
    MACEDONIAN JOURNAL OF CHEMISTRY AND CHEMICAL ENGINEERING, 2012, 31 (02) : 205 - 215
  • [25] An analytical "quality by design" approach in RP-HPLC method development and validation for reliable and rapid estimation of irinotecan in an injectable formulation
    Bhaskaran, Navya Ajitkumar
    Kumar, Lalit
    Reddy, M. Sreenivasa
    Pai, Girish K.
    ACTA PHARMACEUTICA, 2021, 71 (01) : 57 - 79
  • [26] Quality assessment and Analytical Quality by Design-based RP-HPLC method development for quantification of Piperine in Piper nigrum L.
    Vishakha Parab Gaonkar
    Vinodh Kumar Mannur
    Kirankumar Hullatti
    Future Journal of Pharmaceutical Sciences, 8
  • [27] Quality assessment and Analytical Quality by Design-based RP-HPLC method development for quantification of Piperine in Piper nigrum L.
    Gaonkar, Vishakha Parab
    Mannur, Vinodh Kumar
    Hullatti, Kirankumar
    FUTURE JOURNAL OF PHARMACEUTICAL SCIENCES, 2022, 8 (01)
  • [28] New RP-HPLC method with UV-detection for the determination of carvedilol in human serum
    Gannu, Ramesh
    Yamsani, Vamshi Vishnu
    Rao, Yamsani Madhusudan
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2007, 30 (9-12) : 1677 - 1685
  • [29] Development and Validation of a Stability-indicating RP-HPLC Method Using Quality by Design for Estimating Captopril
    Veerubhotla, K.
    Walker, R. B.
    INDIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2019, 81 (01) : 45 - 56
  • [30] Analytical quality by design approach to RP-HPLC method development and validation for simultaneous estimation of esomeprazole and naproxen in modified-release dosage form
    Urmi, Khandokar Farjana
    Nawaz, Md. Saddam
    Islam, S. M. Ashraful
    FUTURE JOURNAL OF PHARMACEUTICAL SCIENCES, 2022, 8 (01)