Indoor Climate Monitoring in Office Buildings-Comparative Analysis of Two Office Buildings without Air Conditioning

被引:1
|
作者
Voss, Karsten [1 ]
Voss, Tjado [1 ]
Kaliga, Marvin [1 ]
机构
[1] Univ Wuppertal, Fac Architecture & Civil Engn, Pauluskirchstr 7, D-42285 Wuppertal, Germany
关键词
thermal comfort; indoor air quality; passive cooling; ceiling fans; monitoring; commercial buildings; energy efficiency; ENERGY PERFORMANCE; COMFORT; QUALITY;
D O I
10.3390/en16196790
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Against the background of climate protection and the rising costs of a fossil-fuel-based energy supply, the interest in the energy performance and indoor climate of buildings in real operation is rising. This paper, therefore, deals with the indoor climate investigation of two medium-sized office buildings in Germany by taking measurements over a whole year. These relate to one new building and one refurbished building. Sensors of various types were installed and operated in a large number of office rooms, so that in total results are available for over 100 rooms, typically occupied by one or two persons. The analysis focuses on the indoor temperature in summer and the air quality in winter based on the CO2 concentration. The comfort classes according to DIN EN 16798 including the adaptive comfort approach are used as a basis to cluster the results. Both buildings have movable sun protection and openable windows but no facilities for active cooling. They, thus, represent a large number of existing 'low tech' office buildings in Germany and central Europe. The results reflect the respective building concepts but also show a wide range between the rooms due to the user preferences and behaviour. The refurbished building shows better results, especially in terms of air quality but also in terms of summer room temperatures. This underlines the benefit of the targeted measures as a result of an analysis of the deficits in the existing building before the refurbishment. The additional measures for decentralised mechanical ventilation and passive cooling are having positive effects. As part of the projects, further measures to improve the indoor climate were investigated in both buildings. In one case, this involved CO2 traffic lights to stimulate personal window ventilation in winter, and in the other, the use of newly developed individual ceiling fans supports convective heat dissipation on the human body during hot spells in summer. The positive effect could be demonstrated for both measures.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Analysis of indoor environmental quality in some domiciles and office buildings in Guangzhou City
    Hu, DQ
    Zhu, DM
    Li, YW
    Zhang, SC
    BUILT ENVIRONMENT AND PUBLIC HEALTH, PROCEEDINGS, 2004, : 133 - 138
  • [32] Development of an indoor environment evaluation model for heating, ventilation and air-conditioning control system of office buildings in subtropical region considering indoor health and thermal comfort
    Huang, Miaohong
    Liao, Yundan
    INDOOR AND BUILT ENVIRONMENT, 2022, 31 (03) : 807 - 819
  • [33] Indoor humidity levels and associations with reported symptoms in office buildings
    Jones, Emily R.
    Cedeno Laurent, Jose Guillermo
    Young, Anna S.
    Coull, Brent A.
    Spengler, John D.
    Allen, Joseph G.
    INDOOR AIR, 2022, 32 (01)
  • [34] GASEOUS AND THERMAL ANALYSIS OF WINTER GARDEN USED FOR AIR REGENERATION THROUGHOUT OFFICE BUILDINGS
    Rymarov, Andrey
    Parfenteva, Natalia
    Valancius, Kestutis
    Paulauskaite, Sabina
    Miseviciute, Violeta
    JOURNAL OF ENVIRONMENTAL ENGINEERING AND LANDSCAPE MANAGEMENT, 2018, 26 (03) : 195 - 201
  • [35] Development of a cooling load prediction model for air-conditioning system control of office buildings
    Fan, Chengliang
    Liao, Yundan
    Ding, Yunfei
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2019, 14 (01) : 70 - 75
  • [36] Low carbon operation optimisation strategies for heating, ventilation and air conditioning systems in office buildings
    Shen, Meng
    Tang, Baojun
    Zhang, Keai
    INTERNATIONAL JOURNAL OF PRODUCTION RESEARCH, 2024, 62 (18) : 6781 - 6800
  • [37] Characterizing indoor environmental quality in Portuguese office buildings for designing an intervention program
    Felgueiras, Fatima
    Mourao, Zenaida
    Moreira, Andre
    Gabriel, Marta Fonseca
    BUILDING AND ENVIRONMENT, 2024, 254
  • [38] Indoor air quality investigation before and after relocation to WELL-certified office buildings
    Licina, Dusan
    Langer, Sarka
    BUILDING AND ENVIRONMENT, 2021, 204
  • [39] Field Measurement, Survey and Evaluation on Indoor Thermal Environments in Typical Office Buildings
    Tao, Pengfei
    Li, Angui
    Qiu, Guozhi
    Zhang, Junfu
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 1: INDOOR AND OUTDOOR ENVIRONMENT, 2014, 261 : 77 - 86
  • [40] Model-based controllers for indoor climate control in office buildings - Complexity and performance evaluation
    Gruber, Mattias
    Truschel, Anders
    Dalenback, Jan-Olof
    ENERGY AND BUILDINGS, 2014, 68 : 213 - 222