Indoor Climate Monitoring in Office Buildings-Comparative Analysis of Two Office Buildings without Air Conditioning

被引:1
|
作者
Voss, Karsten [1 ]
Voss, Tjado [1 ]
Kaliga, Marvin [1 ]
机构
[1] Univ Wuppertal, Fac Architecture & Civil Engn, Pauluskirchstr 7, D-42285 Wuppertal, Germany
关键词
thermal comfort; indoor air quality; passive cooling; ceiling fans; monitoring; commercial buildings; energy efficiency; ENERGY PERFORMANCE; COMFORT; QUALITY;
D O I
10.3390/en16196790
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Against the background of climate protection and the rising costs of a fossil-fuel-based energy supply, the interest in the energy performance and indoor climate of buildings in real operation is rising. This paper, therefore, deals with the indoor climate investigation of two medium-sized office buildings in Germany by taking measurements over a whole year. These relate to one new building and one refurbished building. Sensors of various types were installed and operated in a large number of office rooms, so that in total results are available for over 100 rooms, typically occupied by one or two persons. The analysis focuses on the indoor temperature in summer and the air quality in winter based on the CO2 concentration. The comfort classes according to DIN EN 16798 including the adaptive comfort approach are used as a basis to cluster the results. Both buildings have movable sun protection and openable windows but no facilities for active cooling. They, thus, represent a large number of existing 'low tech' office buildings in Germany and central Europe. The results reflect the respective building concepts but also show a wide range between the rooms due to the user preferences and behaviour. The refurbished building shows better results, especially in terms of air quality but also in terms of summer room temperatures. This underlines the benefit of the targeted measures as a result of an analysis of the deficits in the existing building before the refurbishment. The additional measures for decentralised mechanical ventilation and passive cooling are having positive effects. As part of the projects, further measures to improve the indoor climate were investigated in both buildings. In one case, this involved CO2 traffic lights to stimulate personal window ventilation in winter, and in the other, the use of newly developed individual ceiling fans supports convective heat dissipation on the human body during hot spells in summer. The positive effect could be demonstrated for both measures.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Energy Consumption and Indoor Climate Analysis of Office Buildings
    Thalfeldt, Martin
    ADVANCES IN ENVIRONMENTAL AND GEOLOGICAL SCIENCE AND ENGINEERING, 2010, : 192 - +
  • [2] Thermal Comfort and Indoor Air Quality of Task Ambient Air Conditioning in Modern Office Buildings
    Zheng, Guozhong
    Jing, Youyin
    Huang, Hongxia
    Ma, Puzhao
    2009 INTERNATIONAL CONFERENCE ON INFORMATION MANAGEMENT, INNOVATION MANAGEMENT AND INDUSTRIAL ENGINEERING, VOL 2, PROCEEDINGS, 2009, : 533 - +
  • [3] Indoor air quality in urban office buildings
    Faria, T.
    Almeida-Silva, M.
    Dias, Ana
    Almeida, S. M.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL TECHNOLOGY AND MANAGEMENT, 2016, 19 (3-4) : 236 - 256
  • [4] Analysis of the impact of a fresh air system on the indoor environment in office buildings
    Niu, Run Ping
    Chen, Xiaoyi
    Liu, Hua
    SUSTAINABLE CITIES AND SOCIETY, 2022, 83
  • [5] A preliminary evaluation of two strategies for raising indoor air temperature setpoints in office buildings
    Roussac, A. Craig
    Steinfeld, Jesse
    de Dear, Richard
    ARCHITECTURAL SCIENCE REVIEW, 2011, 54 (02) : 148 - 156
  • [6] Comparative analysis of indoor air quality in green office buildings of varying star levels based on the grey method
    Wu, Peihao
    Fang, Zhaosong
    Luo, Hui
    Zheng, Zhimin
    Zhu, Kaiyue
    Yang, Yanping
    Zhou, Xiaoqing
    BUILDING AND ENVIRONMENT, 2021, 195
  • [7] Comparative study of air-conditioning energy use of four office buildings in China and USA
    Zhou, Xin
    Yan, Da
    An, Jingjing
    Hong, Tianzhen
    Shi, Xing
    Jin, Xing
    ENERGY AND BUILDINGS, 2018, 169 : 344 - 352
  • [8] Formaldehyde and aromatic volatile hydrocarbons in the indoor air of Egyptian office buildings
    Khoder, M. I.
    INDOOR AND BUILT ENVIRONMENT, 2006, 15 (04) : 379 - 387
  • [9] European indoor air quality audit project in 56 office buildings
    Bluyssen, PM
    Fernandes, ED
    Groes, L
    Clausen, G
    Fanger, PO
    Valbjorn, O
    Bernhard, CA
    Roulet, CA
    INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1996, 6 (04): : 221 - 238
  • [10] Energy and Cost Associated with Ventilating Office Buildings in a Tropical Climate
    Rim, Donghyun
    Schiavon, Stefano
    Nazaroff, William W.
    PLOS ONE, 2015, 10 (03):