Fast Low Rank Column-Wise Compressive Sensing for Accelerated Dynamic MRI

被引:7
|
作者
Babu, Silpa [1 ]
Lingala, Sajan Goud [2 ]
Vaswani, Namrata [1 ]
机构
[1] Iowa State Univ, Dept Elect & Comp Engn, Ames, IA 50011 USA
[2] Univ Iowa, Dept Biomed Engn, Iowa City, IA 52242 USA
关键词
Magnetic resonance imaging; Image reconstruction; Heuristic algorithms; Computational modeling; Compressed sensing; Approximation algorithms; Minimization; low-rank; MRI; SPARSE MRI; RECONSTRUCTION; VALIDATION; RECOVERY;
D O I
10.1109/TCI.2023.3263810
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This work develops a novel set of algorithms, alternating Gradient Descent (GD) and minimization for MRI (altGDmin-MRI1 and altGDmin-MRI2), for accelerated dynamic MRI by assuming an approximate low-rank (LR) model on the matrix formed by the vectorized images of the sequence. The LR model itself is well-known in the MRI literature; our contribution is the novel GD-based algorithms which are much faster, memory-efficient, and 'general' compared with existing work; and careful use of a 3-level hierarchical LR model. By 'general,' we mean that, with a single choice of parameters, our method provides accurate reconstructions for multiple accelerated dynamic MRI applications, multiple sampling rates and sampling schemes. We show that our methods outperform many of the popular existing approaches while also being faster than all of them, on average. This claim is based on comparisons on 8 different retrospectively undersampled multi-coil dynamic MRI applications, sampled using either 1D Cartesian or 2D pseudo-radial undersampling, at multiple sampling rates. Evaluations on some prospectively undersampled datasets are also provided. Our second contribution is a mini-batch subspace tracking extension that can process new measurements and return reconstructions within a short delay after they arrive. The recovery algorithm itself is also faster than its batch counterpart.
引用
收藏
页码:409 / 424
页数:16
相关论文
共 50 条
  • [21] Accelerated cardiac cine MRI using locally low rank and finite difference constraints
    Miao, Xin
    Lingala, Sajan Goud
    Guo, Yi
    Jao, Terrence
    Usman, Muhammad
    Prieto, Claudia
    Nayak, Krishna S.
    MAGNETIC RESONANCE IMAGING, 2016, 34 (06) : 707 - 714
  • [22] Accelerated dynamic EPR imaging using fast acquisition and compressive recovery
    Ahmad, Rizwan
    Samouilov, Alexandre
    Zweier, Jay L.
    JOURNAL OF MAGNETIC RESONANCE, 2016, 273 : 105 - 112
  • [23] Compressive sensing via nonlocal low-rank tensor regularization
    Feng, Lei
    Sun, Huaijiang
    Sun, Quansen
    Xia, Guiyu
    NEUROCOMPUTING, 2016, 216 : 45 - 60
  • [24] Fast Implementation for Compressive Recovery of Highly Accelerated Cardiac Cine MRI Using the Balanced Sparse Model
    Ting, Samuel T.
    Ahmad, Rizwan
    Jin, Ning
    Craft, Jason
    da Silveira, Juliana Serafim
    Xue, Hui
    Simonetti, Orlando P.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (04) : 1505 - 1515
  • [25] Bi-smooth constraints for accelerated dynamic MRI with low-rank plus sparse tensor decomposition
    He, Jingfei
    Liu, Xiaotong
    Luan, Nannan
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 82
  • [26] Compressive Sensing Imaging with Randomized Lattice Sampling: Applications to Fast 3D MRI
    Ji, Jim X.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 3736 - 3739
  • [27] Low-rank plus sparse compressed sensing for accelerated proton resonance frequency shift MR temperature imaging
    Cao, Zhipeng
    Gore, John C.
    Grissom, William A.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (06) : 3555 - 3566
  • [28] Low-Rank and Sparse Decomposition Model for Accelerating Dynamic MRI Reconstruction
    Chen, Junbo
    Liu, Shouyin
    Huang, Min
    JOURNAL OF HEALTHCARE ENGINEERING, 2017, 2017
  • [29] Considering low-rank, sparse and gas-inflow effects constraints for accelerated pulmonary dynamic hyperpolarized 129Xe MRI
    Xiao, Sa
    Deng, He
    Duan, Caohui
    Xie, Junshuai
    Zhang, Huiting
    Sun, Xianping
    Ye, Chaohui
    Zhou, Xin
    JOURNAL OF MAGNETIC RESONANCE, 2018, 290 : 29 - 37
  • [30] PCLR: Phase-Constrained Low-Rank Model for Compressive Diffusion-Weighted MRI
    Gao, Hao
    Li, Longchuan
    Zhang, Kai
    Zhou, Weifeng
    Hu, Xiaoping
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (05) : 1330 - 1341