An Equivalent Differential Method for Active Damping of LCL Type Grid-Connected Inverters With Grid-Side Inductor Voltage Feedback

被引:4
|
作者
Li, Mingming [1 ]
Ren, Yinwei [2 ]
Xiao, Huafeng [1 ]
Niu, Chenghui [3 ]
Cheng, Ming [1 ]
机构
[1] Southeast Univ, Coll Elect Engn, Nanjing 210096, Peoples R China
[2] Everbright bioenergy Suqian Co Ltd, Suqian 223800, Peoples R China
[3] Huaneng Jiangsu Co Ltd, Nanjing 210015, Peoples R China
关键词
Band-pass filters; Damping; Power harmonic filters; Resonant frequency; Harmonic analysis; Capacitors; Inverters; Active damping; band-pass filter (BPF); differential link; lead compensation; DIGITAL DIFFERENTIATORS; FILTERED INVERTER; DESIGN; REALIZATION;
D O I
10.1109/TPEL.2023.3252163
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The differential feedback of grid-side inductor voltage can effectively increase the damping of grid-connected inverters. Compared with proportional feedback of filter capacitor current, it can increase the output impedance of the grid-connected inverters, which is more conducive to reducing the impact of grid background harmonics on the grid-in current. However, there is a differential link in its damping branch, and existing differential implementation methods were pursuing to be ideal differential in wide frequency band, as a consequence, high-frequency components of the grid-side inductor voltage are amplified, which affects the quality of grid-in current. For this reason, this article proposes a band-pass filter in series with a lead compensation unit to replace the ideal differential. The major advantage different from the conventional methods is that the proposed strategy is only equivalent to the ideal differential around the resonance frequency band. Specifically, it features lower gain at low- and high-frequency bands. Finally, theoretical analysis and experiment results show that the proposed strategy can reduce the influence of the added damping path on th fundamental component of grid-in current and features better suppression effect on the harmonics.
引用
收藏
页码:7009 / 7021
页数:13
相关论文
共 50 条
  • [1] Active damping strategy with differential feedback of grid-side inductor voltage for LCL-filtered grid-connected inverters
    Mingming Li
    Hua F. Xiao
    Ming Cheng
    Journal of Power Electronics, 2022, 22 : 176 - 186
  • [2] Active damping strategy with differential feedback of grid-side inductor voltage for LCL-filtered grid-connected inverters
    Li, Mingming
    Xiao, Hua F.
    Cheng, Ming
    JOURNAL OF POWER ELECTRONICS, 2022, 22 (02) : 176 - 186
  • [3] An Improved Active Damping Method with Grid-Side Current Feedback to Maximize Damping Ratio for LCL-Type Grid-Connected Inverter
    Wu, Weibiao
    Peng, Li
    Qi, Yu
    Liu, Qian
    Huang, Zeyi
    Dong, Fangming
    Chen, Manlin
    Wang, Bowen
    2017 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2017, : 5607 - 5611
  • [4] A Virtual RLC Active Damping Method for LCL-Type Grid-Connected Inverters
    Geng, Yiwen
    Qi, Yawen
    Zheng, Pengfei
    Guo, Fei
    Gao, Xiang
    JOURNAL OF POWER ELECTRONICS, 2018, 18 (05) : 1555 - 1566
  • [5] Synthesis of Active Damping for Grid-Connected Inverters with an LCL filter
    Xiao, Huafeng
    Qu, Xiaohui
    Xie, Shaojun
    Xu, Jinming
    2012 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2012, : 550 - 556
  • [6] A High-Robust Grid-Side Current Feedback Active Damping Design Method for Grid-connected Inverter
    Xu, Ke
    Peng, Li
    Wu, Weibiao
    Lin, Bowei
    Yang, Shirong
    2019 10TH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND ECCE ASIA (ICPE 2019 - ECCE ASIA), 2019,
  • [7] A Joint Active Damping Strategy Based on LCL-Type Grid-Connected Inverters for Grid Current Feedback and PCC Voltage Unit Feedforward
    Ke, Shanwen
    Liang, Bo
    SENSORS, 2024, 24 (18)
  • [8] Virtual Impedance-Based Active Damping for LCL Resonance in Grid-Connected Voltage Source Inverters with Grid Current Feedback
    Liu, Teng
    Liu, Zeng
    Liu, Jinjun
    Liu, Zipeng
    2016 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2016,
  • [9] Virtual RLC Active Damping for Grid-Connected Inverters with LCL Filters
    Huang, Qicheng
    Rajashekara, Kaushik
    2017 THIRTY SECOND ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2017, : 424 - 429
  • [10] Passivity-Based Design of Grid-Side Current-Controlled LCL-Type Grid-Connected Inverters
    Xie, Chuan
    Li, Kai
    Zou, Jianxiao
    Liu, Dong
    Guerrero, Josep M.
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2020, 35 (09) : 9813 - 9823