Hyperpolarized 129Xe MRI at low field: Current status and future directions

被引:3
|
作者
Perron, Samuel [1 ,4 ]
Ouriadov, Alexei [1 ,2 ,3 ]
机构
[1] Univ Western Ontario, Dept Phys & Astron, London, ON, Canada
[2] Lawson Hlth Res Inst, London, ON, Canada
[3] Univ Western Ontario, Fac Engn, Sch Biomed Engn, London, ON, Canada
[4] Univ Western Ontario, Dept Phys & Astron, PAB Room 222,1151 Richmond St, London, ON NGA 3K7, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Hyperpolarized Nobles Gas; Low field MRI; Xenon-129; Lung imaging; RF Coils; TO-NOISE RATIO; NUCLEAR-MAGNETIC-RESONANCE; DIFFUSION-COEFFICIENT ANISOTROPY; IN-VIVO; HEALTHY-VOLUNTEERS; HUMAN LUNG; SPATIAL-RESOLUTION; NMR-SPECTROSCOPY; REGIONAL VENTILATION; POLARIZED XE-129;
D O I
10.1016/j.jmr.2023.107387
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Magnetic Resonance Imaging (MRI) is dictated by the magnetization of the sample, and is thus a lowsensitivity imaging method. Inhalation of hyperpolarized (HP) noble gases, such as helium-3 and xenon-129, is a non-invasive, radiation-risk free imaging technique permitting high resolution imaging of the lungs and pulmonary functions, such as the lung microstructure, diffusion, perfusion, gas exchange, and dynamic ventilation. Instead of increasing the magnetic field strength, the higher spin polarization achievable from this method results in significantly higher net MR signal independent of tissue/water concentration. Moreover, the significantly longer apparent transverse relaxation time T2* of these HP gases at low magnetic field strengths results in fewer necessary radiofrequency (RF) pulses, permitting larger flip angles; this allows for high-sensitivity imaging of in vivo animal and human lungs at conventionally low (<0.5 T) field strengths and suggests that the low field regime is optimal for pulmonary MRI using hyperpolarized gases. In this review, theory on the common spin-exchange optical-pumping method of hyperpolarization and the field dependence of the MR signal of HP gases are presented, in the context of human lung imaging. The current state-of-the-art is explored, with emphasis on both MRI hardware (low field scanners, RF coils, and polarizers) and image acquisition techniques (pulse sequences) advancements. Common challenges surrounding imaging of HP gases and possible solutions are discussed, and the future of low field hyperpolarized gas MRI is posed as being a clinically-accessible and versatile imaging method, circumventing the siting restrictions of conventional high field scanners and bringing point-of-care pulmonary imaging to global facilities.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Hyperpolarized 129Xe MRI of the human lung
    Mugler, John P.
    Altes, Talissa A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (02) : 313 - 331
  • [2] Application of a 2D frequency encoding sectoral approach to hyperpolarized 129Xe MRI at low field
    Perron, Samuel
    Ouriadov, Alexei
    Wawrzyn, Krzysztof
    Hickling, Susannah
    Fox, Matthew S.
    Serrai, Hacene
    Santyr, Giles
    JOURNAL OF MAGNETIC RESONANCE, 2022, 336
  • [3] Preclinical MRI Using Hyperpolarized 129Xe
    Kadlecek, Stephen
    Friedlander, Yonni
    Virgincar, Rohan S.
    MOLECULES, 2022, 27 (23):
  • [4] Hyperpolarized 129Xe imaging of the brain: Achievements and future challenges
    Shepelytskyi, Yurii
    Grynko, Vira
    Rao, Madhwesha R.
    Li, Tao
    Agostino, Martina
    Wild, Jim M.
    Albert, Mitchell S.
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (01) : 83 - 105
  • [5] Fast dynamic ventilation MRI of hyperpolarized 129Xe using spiral imaging
    Doganay, Ozkan
    Matin, Tahreema N.
    Mcintyre, Anthony
    Burns, Brian
    Schulte, Rolf F.
    Gleeson, Fergus V.
    Bulte, Daniel
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (05) : 2597 - 2606
  • [6] Quantitative analysis of hyperpolarized 129Xe gas transfer MRI
    Wang, Ziyi
    Robertson, Scott Haile
    Wang, Jennifer
    He, Mu
    Virgincar, Rohan S.
    Schrank, Geoffry M.
    Bier, Elianna A.
    Rajagopal, Sudarshan
    Huang, Yuh Chin
    O'Riordan, Thomas G.
    Rackley, Craig R.
    McAdams, H. Page
    Driehuys, Bastiaan
    MEDICAL PHYSICS, 2017, 44 (06) : 2415 - 2428
  • [7] Human Pulmonary Hyperpolarized 129Xe MRI: a Preliminary Study
    Yang, Hao
    Wang, Ke
    Zhang, Hui-Ting
    Xie, Jun-Shuai
    Wu, Guang-Yao
    Zhou, Xin
    CHINESE PHYSICS LETTERS, 2018, 35 (05)
  • [8] Dose and pulse sequence considerations for hyperpolarized 129Xe ventilation MRI
    He, Mu
    Robertson, Scott H.
    Kaushik, S. Sivaram
    Freeman, Matthew S.
    Virgincar, Rohan S.
    Davies, John
    Stiles, Jane
    Foster, William M.
    McAdams, H. Page
    Driehuys, Bastiaan
    MAGNETIC RESONANCE IMAGING, 2015, 33 (07) : 877 - 885
  • [9] Using Hyperpolarized 129Xe MRI to Quantify the Pulmonary Ventilation Distribution
    He, Mu
    Driehuys, Bastiaan
    Que, Loretta G.
    Huang, Yuh-Chin T.
    ACADEMIC RADIOLOGY, 2016, 23 (12) : 1521 - 1531
  • [10] Hyperpolarized 129Xe MRI:: A viable functional lung imaging modality?
    Patz, Samuel
    Hersman, F. William
    Muradian, Iga
    Hrovat, Mirko I.
    Ruset, Iulian C.
    Ketel, Stephen
    Jacobson, Francine
    Topulos, George P.
    Hatabu, Hiroto
    Butler, James P.
    EUROPEAN JOURNAL OF RADIOLOGY, 2007, 64 (03) : 335 - 344