Benchmarking the Effects on Human-Exoskeleton Interaction of Trajectory, Admittance and EMG-Triggered Exoskeleton Movement Control

被引:7
|
作者
Rodrigues-Carvalho, Camila [1 ,2 ]
Fernandez-Garcia, Marvin [3 ]
Pinto-Fernandez, David [1 ,4 ]
Sanz-Morere, Clara [5 ]
Barroso, Filipe Oliveira [1 ]
Borromeo, Susana [3 ]
Rodriguez-Sanchez, Cristina [3 ]
Moreno, Juan C. [1 ]
del-Ama, Antonio J. [3 ]
机构
[1] CSIC, Cajal Inst, Neural Rehabil Grp, Madrid 28002, Spain
[2] Carlos III Univ Madrid, Syst Engn & Automat Dept, Madrid 28903, Spain
[3] Rey Juan Carlos Univ, Elect Technol Dept, Mostoles 28933, Spain
[4] Univ Politecn Madrid, CAR UPM Associated Unit, Madrid 28040, Spain
[5] Hosp Los Madronos, Ctr Clin Neurosci, Madrid 28690, Spain
基金
欧盟地平线“2020”;
关键词
exoskeleton; human-robot interaction; electromyography; EMG control; exoskeleton control; benchmarking; MUSCLE-ACTIVITY; ROBOT; NEUROREHABILITATION; REDUCTION; ROBUST; ONSET;
D O I
10.3390/s23020791
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Nowadays, robotic technology for gait training is becoming a common tool in rehabilitation hospitals. However, its effectiveness is still controversial. Traditional control strategies do not adequately integrate human intention and interaction and little is known regarding the impact of exoskeleton control strategies on muscle coordination, physical effort, and user acceptance. In this article, we benchmarked three types of exoskeleton control strategies in a sample of seven healthy volunteers: trajectory assistance (TC), compliant assistance (AC), and compliant assistance with EMG-Onset stepping control (OC), which allows the user to decide when to take a step during the walking cycle. This exploratory study was conducted within the EUROBENCH project facility. Experimental procedures and data analysis were conducted following EUROBENCH's protocols. Specifically, exoskeleton kinematics, muscle activation, heart and breathing rates, skin conductance, as well as user-perceived effort were analyzed. Our results show that the OC controller showed robust performance in detecting stepping intention even using a corrupt EMG acquisition channel. The AC and OC controllers resulted in similar kinematic alterations compared to the TC controller. Muscle synergies remained similar to the synergies found in the literature, although some changes in muscle contribution were found, as well as an overall increase in agonist-antagonist co-contraction. The OC condition led to the decreased mean duration of activation of synergies. These differences were not reflected in the overall physiological impact of walking or subjective perception. We conclude that, although the AC and OC walking conditions allowed the users to modulate their walking pattern, the application of these two controllers did not translate into significant changes in the overall physiological cost of walking nor the perceived experience of use. Nonetheless, results suggest that both AC and OC controllers are potentially interesting approaches that can be explored as gait rehabilitation tools. Furthermore, the INTENTION project is, to our knowledge, the first study to benchmark the effects on human-exoskeleton interaction of three different exoskeleton controllers, including a new EMG-based controller designed by us and never tested in previous studies, which has made it possible to provide valuable third-party feedback on the use of the EUROBENCH facility and testbed, enriching the apprenticeship of the project consortium and contributing to the scientific community.
引用
收藏
页数:22
相关论文
共 49 条
  • [31] Research on optimization of human-machine interaction control strategy for exoskeleton based on impedance control
    Guanchao Li
    Hualong Xie
    Xiangxiang Wang
    Zhen Chen
    Journal of Mechanical Science and Technology, 2023, 37 : 1411 - 1420
  • [32] Research on optimization of human-machine interaction control strategy for exoskeleton based on impedance control
    Li, Guanchao
    Xie, Hualong
    Wang, Xiangxiang
    Chen, Zhen
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2023, 37 (03) : 1411 - 1420
  • [33] An Interaction Torque Control Improving Human Force Estimation of the Rehab-Exos Exoskeleton
    Solazzi, Massimiliano
    Abbrescia, Mirko
    Vertechy, Rocco
    Loconsole, Claudio
    Bevilacqua, Vitoantonio
    Frisoli, Antonio
    2014 IEEE HAPTICS SYMPOSIUM (HAPTICS), 2014, : 187 - 193
  • [34] Human-machine force interaction design and control for the HIT load-carrying exoskeleton
    Zhang, Chao
    Zang, Xizhe
    Leng, Zhengfei
    Yu, Hongying
    Zhao, Jie
    Zhu, Yanhe
    ADVANCES IN MECHANICAL ENGINEERING, 2016, 8 (04) : 1 - 14
  • [35] Real-Time EEG-EMG Human-Machine Interface-Based Control System for a Lower-Limb Exoskeleton
    Gordleeva, Susanna Yu
    Lobov, Sergey A.
    Grigorev, Nikita A.
    Savosenkov, Andrey O.
    Shamshin, Maxim O.
    Lukoyanov, Maxim, V
    Khoruzhko, Maxim A.
    Kazantsev, Victor B.
    IEEE ACCESS, 2020, 8 : 84070 - 84081
  • [36] Hip-Knee-Ankle Rehabilitation Exoskeleton With Compliant Actuators: From Human-Robot Interaction Control to Clinical Evaluation
    Chen, Wanxin
    Zhang, Bi
    Tan, Xiaowei
    Zhao, Yiwen
    Liu, Lianqing
    Zhao, Xingang
    IEEE TRANSACTIONS ON ROBOTICS, 2025, 41 : 269 - 288
  • [37] Exploring Human-Exoskeleton Interaction Dynamics: An In-Depth Analysis of Knee Flexion-Extension Performance across Varied Robot Assistance-Resistance Configurations
    Mosconi, Denis
    Moreno, Yecid
    Siqueira, Adriano
    SENSORS, 2024, 24 (08)
  • [38] Measuring the Improvement of the Interaction Comfort of a Wearable Exoskeleton A Multi-Modal Control Mechanism Based on Force Measurement and Movement Prediction
    Folgheraiter, Michele
    Jordan, Mathias
    Straube, Sirko
    Seeland, Anett
    Kim, Su Kyoung
    Kirchner, Elsa Andrea
    INTERNATIONAL JOURNAL OF SOCIAL ROBOTICS, 2012, 4 (03) : 285 - 302
  • [39] Adaptive fuzzy impedance control of exoskeleton robots with electromyography-based convolutional neural networks for human intended trajectory estimation
    Foroutannia, Ali
    Akbarzadeh-T, Mohammad-R.
    Akbarzadeh, Alireza
    Tahamipour-Z, S. Mohammad
    MECHATRONICS, 2023, 91
  • [40] Human-robot cooperative control based on pHRI (Physical Human-Robot Interaction) of exoskeleton robot for a human upper extremity
    Heedon Lee
    Byeongkyu Lee
    Wansoo Kim
    Myeongsoo Gil
    Jungsoo Han
    Changsoo Han
    International Journal of Precision Engineering and Manufacturing, 2012, 13 : 985 - 992