Validation of a highly accelerated post-contrast wave-controlled aliasing in parallel imaging (CAIPI) 3D-T1 MPRAGE compared to standard 3D-T1 MPRAGE for detection of intracranial enhancing lesions on 3-T MRI

被引:10
作者
Goncalves Filho, Augusto Lio M. [1 ,2 ]
Awan, Komal Manzoor [1 ,2 ]
Conklin, John [1 ,2 ]
Ngamsombat, Chanon [2 ,3 ]
Cauley, Stephen F. [1 ,2 ]
Setsompop, Kawin [1 ,2 ]
Liu, Wei [4 ]
Splitthoff, Daniel N. [5 ]
Lo, Wei-Ching [6 ]
Kirsch, John E. [1 ,2 ]
Schaefer, Pamela W. [1 ]
Rapalino, Otto [1 ]
Huang, Susie Y. [1 ,2 ,7 ]
机构
[1] Harvard Med Sch, Massachusetts Gen Hosp MGH, Dept Radiol, 55 Fruit St, Boston, MA 02114 USA
[2] Athinoula A Martinos Ctr Biomed Imaging, Charlestown, MA 02129 USA
[3] Mahidol Univ, Siriraj Hosp, Fac Med, Dept Radiol, Nakhon Pathom, Thailand
[4] Siemens Shenzhen Magnet Resonance Ltd, Shenzhen, Peoples R China
[5] Siemens Healthcare GmbH, Erlangen, Germany
[6] Siemens Med Solut Inc, Boston, MA USA
[7] Massachusetts Gen Hosp, Dept Radiol, Div Neuroradiol, 55 Fruit St,GRB 273A, Boston, MA 02114 USA
基金
美国国家卫生研究院;
关键词
Magnetic resonance imaging; Neuroimaging; Three-dimensional imaging; Acceleration; Gadolinium; CONSENSUS RECOMMENDATIONS; PROTOCOL;
D O I
10.1007/s00330-022-09265-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives High-resolution post-contrast T1-weighted imaging is a workhorse sequence in the evaluation of neurological disorders. The T1-MPRAGE sequence has been widely adopted for the visualization of enhancing pathology in the brain. However, this three-dimensional (3D) acquisition is lengthy and prone to motion artifact, which often compromises diagnostic quality. The goal of this study was to compare a highly accelerated wave-controlled aliasing in parallel imaging (CAIPI) post-contrast 3D T1-MPRAGE sequence (Wave-T1-MPRAGE) with the standard 3D T1-MPRAGE sequence for visualizing enhancing lesions in brain imaging at 3 T.Methods This study included 80 patients undergoing contrast-enhanced brain MRI. The participants were scanned with a standard post-contrast T1-MPRAGE sequence (acceleration factor [R] = 2 using GRAPPA parallel imaging technique, acquisition time [TA] = 5 min 18 s) and a prototype post-contrast Wave-T1-MPRAGE sequence (R = 4, TA = 2 min 32 s). Two neuroradiologists performed a head-to-head evaluation of both sequences and rated the visualization of enhancement, sharpness, noise, motion artifacts, and overall diagnostic quality. A 15% noninferiority margin was used to test whether post-contrast Wave-T1-MPRAGE was noninferior to standard T1-MPRAGE. Inter-rater and intra-rater agreement were calculated. Quantitative assessment of CNR/SNR was performed.Results Wave-T1-MPRAGE was noninferior to standard T1-MPRAGE for delineating enhancing lesions with unanimous agreement in all cases between raters. Wave-T1-MPRAGE was noninferior in the perception of noise (p < 0.001), motion artifact (p < 0.001), and overall diagnostic quality (p < 0.001).Conclusion High-accelerated post-contrast Wave-T1-MPRAGE enabled a two-fold reduction in acquisition time compared to the standard sequence with comparable performance for visualization of enhancing pathology and equivalent perception of noise, motion artifacts and overall diagnostic quality without loss of clinically important information.
引用
收藏
页码:2905 / 2915
页数:11
相关论文
共 22 条
[1]   How to Demonstrate Similarity by Using Noninferiority and Equivalence Statistical Testing in Radiology Research [J].
Ahn, Soyeon ;
Park, Seong Ho ;
Lee, Kyoung Ho .
RADIOLOGY, 2013, 267 (02) :328-338
[2]   Recommendations for the use of structural magnetic resonance imaging in the care of patients with epilepsy: A consensus report from the International League Against Epilepsy Neuroimaging Task Force [J].
Bernasconi, Andrea ;
Cendes, Fernando ;
Theodore, William H. ;
Gill, Ravnoor S. ;
Koepp, Matthias J. ;
Hogan, Robert Edward ;
Jackson, Graeme D. ;
Federico, Paolo ;
Labate, Angelo ;
Vaudano, Anna Elisabetta ;
Bluemcke, Ingmar ;
Ryvlin, Philippe ;
Bernasconi, Neda .
EPILEPSIA, 2019, 60 (06) :1054-1068
[3]   Wave-CAIPI for highly accelerated 3D imaging [J].
Bilgic, Berkin ;
Gagoski, Borjan A. ;
Cauley, Stephen F. ;
Fan, Audrey P. ;
Polimeni, Jonathan R. ;
Grant, P. Ellen ;
Wald, Lawrence L. ;
Setsompop, Kawin .
MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (06) :2152-2162
[4]   Modality Access: Strategies for Optimizing Throughput [J].
Boland, Giles W. ;
Duszak, Richard, Jr. .
JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2015, 12 (10) :1073-1075
[5]   Autocalibrated wave-CAIPI reconstruction; Joint optimization of k-space trajectory and parallel imaging reconstruction [J].
Cauley, Stephen F. ;
Setsompop, Kawin ;
Bilgic, Berkin ;
Bhat, Himanshu ;
Gagoski, Borjan ;
Wald, Lawrence L. .
MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (03) :1093-1099
[6]  
Chow SC., 2003, SAMPLE SIZE CALCULAT, DOI [10.1201/9780203911341, DOI 10.1201/9780203911341]
[7]   Validation of Highly Accelerated Wave?CAIPI SWI Compared with Conventional SWI and T2*-Weighted Gradient Recalled-Echo for Routine Clinical Brain MRI at 3T [J].
Conklin, J. ;
Longo, M. G. F. ;
Cauley, S. F. ;
Setsompop, K. ;
Gonzalez, R. G. ;
Schaefer, P. W. ;
Kirsch, J. E. ;
Rapalino, O. ;
Huang, S. Y. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (12) :2073-2080
[8]   Nonlesional Sources of Contrast Enhancement on Postgadolinium ?Black-Blood? 3D T1-SPACE Images in Patients with Multiple Sclerosis [J].
Danieli, L. ;
Roccatagliata, L. ;
Distefano, D. ;
Prodi, E. ;
Riccitelli, G. C. ;
Diociasi, A. ;
Carmisciano, L. ;
Cianfoni, A. ;
Bartalena, T. ;
Kaelin-Lang, A. ;
Gobbi, C. ;
Zecca, C. ;
Pravata, E. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2022, 43 (06) :872-880
[9]   Consensus recommendations for a standardized Brain Tumor Imaging Protocol in clinical trials [J].
Ellingson, Benjamin M. ;
Bendszus, Martin ;
Boxerman, Jerrold ;
Barboriak, Daniel ;
Erickson, Bradley J. ;
Smits, Marion ;
Nelson, Sarah J. ;
Gerstner, Elizabeth ;
Alexander, Brian ;
Goldmacher, Gregory ;
Wick, Wolfgang ;
Vogelbaum, Michael ;
Weller, Michael ;
Galanis, Evanthia ;
Kalpathy-Cramer, Jayashree ;
Shankar, Lalitha ;
Jacobs, Paula ;
Pope, Whitney B. ;
Yang, Dewen ;
Chung, Caroline ;
Knopp, Michael V. ;
Cha, Soonme ;
van den Bent, Martin J. ;
Chang, Susan ;
Al Yung, W. K. ;
Cloughesy, Timothy F. ;
Wen, Patrick Y. ;
Gilbert, Mark R. .
NEURO-ONCOLOGY, 2015, 17 (09) :1188-1198
[10]   MRI Highly Accelerated Wave-CAIPI T1-SPACE versus Standard T1-SPACE to detect brain gadolinium-enhancing lesions at 3T [J].
Filho, Augusto Lio M. Goncalves ;
Longo, M. Gabriela Figueiro ;
Conklin, John ;
Cauley, Stephen F. ;
Polak, Daniel ;
Liu, Wei ;
Splitthoff, Daniel N. ;
Lo, Wei-Ching ;
Kirsch, John E. ;
Setsompop, Kawin ;
Schaefer, Pamela W. ;
Huang, Susie Y. ;
Rapalino, Otto .
JOURNAL OF NEUROIMAGING, 2021, 31 (05) :893-901