Dual imaging modality of fluorescence and transmission X-rays for gold nanoparticle-injected living mice

被引:5
作者
Kim, Taeyun [1 ]
Lee, Woo Seung [1 ]
Jeon, Miyeon [1 ]
Kim, Hyejin [1 ]
Eom, Mingi [1 ]
Jung, Seongmoon [2 ]
Im, Hyung-Jun [1 ,3 ]
Ye, Sung-Joon [1 ,3 ,4 ,5 ]
机构
[1] Seoul Natl Univ, Grad Sch Convergence Sci & Technol, Dept Appl Bioengn, Seoul, South Korea
[2] Seoul Natl Univ Hosp, Dept Radiat Oncol, Seoul, South Korea
[3] Seoul Natl Univ, Res Inst Convergence Sci, Seoul, South Korea
[4] Seoul Natl Univ, Adv Inst Convergence Technol, Suwon, South Korea
[5] Seoul Natl Univ Hosp, Biomed Res Inst, Seoul, South Korea
关键词
computed tomography; dual imaging modality; gold nanoparticles; in vivo molecular imaging; X-ray fluorescence imaging; COMPUTED-TOMOGRAPHY; RADIOTHERAPY; TRANSPORT; DELIVERY; CT;
D O I
10.1002/mp.16070
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundX-ray fluorescence (XRF) imaging for metal nanoparticles (MNPs) is a promising molecular imaging modality that can determine dynamic biodistributions of MNPs. However, it has the limitation that it only provides functional information. PurposeIn this study, we aim to show the feasibility of acquiring functional and anatomic information on the same platform by demonstrating a dual imaging modality of pinhole XRF and computed tomography (CT) for gold nanoparticle (GNP)-injected living mice. MethodsBy installing a transmission CT detector in an existing pinhole XRF imaging system using a two-dimensional (2D) cadmium zinc telluride (CZT) gamma camera, XRF and CT images were acquired on the same platform. Due to the optimal X-ray spectra for XRF and CT image acquisition being different, XRF and CT imaging were performed by 140 and 50 kV X-rays, respectively. An amount of 40 mg GNPs (1.9 nm in diameter) suspended in 0.20 ml of phosphate-buffered saline were injected into the three BALB/c mice via a tail vein. Then, the kidney and tumor slices of mice were scanned at specific time points within 60 min to acquire time-lapse in vivo biodistributions of GNPs. XRF images were directly acquired without image reconstruction using a pinhole collimator and a 2D CZT gamma camera. Subsequently, CT images were acquired by performing CT scans. In order to confirm the validity of the functional information provided by the XRF image, the CT image was fused with the XRF image. After the XRF and CT scan, the mice were euthanized, and major organs (kidneys, tumor, liver, and spleen) were extracted. The ex vivo GNP concentrations of the extracted organs were measured by inductively coupled plasma mass spectrometry (ICP-MS) and L-shell XRF detection system using a silicon drift detector, then compared with the in vivo GNP concentrations measured by the pinhole XRF imaging system. ResultsTime-lapse XRF images were directly acquired without rotation and translation of imaging objects within an acquisition time of 2 min per slice. Due to the short image acquisition time, the time-lapse in vivo biodistribution of GNPs was acquired in the organs of the mice. CT images were fused with the XRF images and successfully confirmed the validity of the XRF images. The difference in ex vivo GNP concentrations measured by the L-shell XRF detection system and ICP-MS was 0.0005-0.02% by the weight of gold (wt%). Notably, the in vivo and ex vivo GNP concentrations in the kidneys of three mice were comparable with a difference of 0.01-0.08 wt%. ConclusionsA dual imaging modality of pinhole XRF and CT imaging system and L-shell XRF detection system were successfully developed. The developed systems are a promising modality for in vivo imaging and ex vivo quantification for preclinical studies using MNPs. In addition, we discussed further improvements for the routine preclinical applications of the systems.
引用
收藏
页码:529 / 539
页数:11
相关论文
共 38 条
  • [1] An algorithm for automated modulation transfer function measurement using an edge of a PMMA phantom: Impact of field of view on spatial resolution of CT images
    Anam, Choirul
    Fujibuchi, Toshioh
    Budi, Wahyu Setia
    Haryanto, Freddy
    Dougherty, Geoff
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (06): : 244 - 252
  • [2] Radiosafe micro-computed tomography for longitudinal evaluation of murine disease models
    Berghen, Nathalie
    Dekoster, Kaat
    Marien, Eyra
    Dabin, Jeremie
    Hillen, Amy
    Wouters, Jens
    Deferme, Jasmine
    Vosselman, Thibault
    Tiest, Eline
    Lox, Marleen
    Vanoirbeek, Jeroen
    De Langhe, Ellen
    Bogaerts, Ria
    Hoylaerts, Marc
    Lories, Rik
    Velde, Greetje Vande
    [J]. SCIENTIFIC REPORTS, 2019, 9 (1)
  • [3] X-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticle-loaded objects using 110 kVp x-rays
    Cheong, Seong-Kyun
    Jones, Bernard L.
    Siddiqi, Arsalan K.
    Liu, Fang
    Manohar, Nivedh
    Cho, Sang Hyun
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (03) : 647 - 662
  • [4] Cherry S. R., 2003, PHYS NUCL MED
  • [5] Cho SH, 2013, IMAG MED DIAGN THER, P1, DOI 10.1201/b14049
  • [6] Micro-CT of rodents: State-of-the-art and future perspectives
    Clark, D. P.
    Badea, C. T.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (06): : 619 - 634
  • [7] Investigation of transmission computed tomography (CT) image quality and x-ray dose achievable from an experimental dual-mode benchtop x-ray fluorescence CT and transmission CT system
    Deng, Luzhen
    Yasar, Selcuk
    Ahmed, Md Foiez
    Jayarathna, Sandun
    Feng, Peng
    Wei, Biao
    Vedantham, Srinivasan
    Karellas, Andrew
    Cho, Sang Hyun
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2019, 27 (03) : 431 - 442
  • [8] Surface plasmon resonance scattering and absorption of anti-EGFR antibody conjugated gold nanoparticles in cancer diagnostics: Applications in oral cancer
    El-Sayed, IH
    Huang, XH
    El-Sayed, MA
    [J]. NANO LETTERS, 2005, 5 (05) : 829 - 834
  • [9] A Ring Artifact Correction Method: Validation by Micro-CT Imaging with Flat-Panel Detectors and a 2D Photon-Counting Detector
    Eldib, Mohamed Elsayed
    Hegazy, Mohamed
    Mun, Yang Ji
    Cho, Myung Hye
    Cho, Min Hyoung
    Lee, Soo Yeol
    [J]. SENSORS, 2017, 17 (02)
  • [10] Gold nanoparticles: a new X-ray contrast agent
    Hainfeld, JF
    Slatkin, DN
    Focella, TM
    Smilowitz, HM
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2006, 79 (939) : 248 - 253