4E analysis and multi-objective optimization of compression/ejection transcritical CO2 heat pump with latent thermal heat storage

被引:8
|
作者
Zhang, Dongwei [1 ]
Fang, Chenglei [1 ]
Shen, Chao [2 ]
Chen, Songxuan [3 ,4 ]
Li, Hang [1 ]
Qin, Xiang [1 ]
Liu, He [5 ]
Wu, Xuehong [5 ]
机构
[1] Zhengzhou Univ, Sch Mech & Power Engn, Zhengzhou 450001, Henan, Peoples R China
[2] Zhengzhou Univ, Sch Civil Engn, Zhengzhou 450001, Henan, Peoples R China
[3] China ENFI Engn Co Ltd, Beijing 100038, Peoples R China
[4] Univ Chinese Acad Sci, Sch Chem Engn, Beijing 100190, Peoples R China
[5] Zhengzhou Univ Light Ind, Sch Energy & Power Engn, Zhengzhou 450002, Henan, Peoples R China
关键词
Heat pump; Coefficient of performance; Exergy efficiency; Economic and environmental analysis; Multi-objective optimization; WATER-HEATER; REFRIGERATION; PERFORMANCE; SYSTEM;
D O I
10.1016/j.est.2023.108475
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
To promote the goal of peak carbon dioxide emissions and carbon neutrality, low-energy consumption buildings require innovative technologies and efficient energy management. In this paper, the multi-objective optimization and the energy, exergy, economic and environmental (4E) analyses of the compression/ejection transcritical CO2 heat pump with latent thermal storage (TPE-LTES) system are conducted, and the influences of crucial parameters on the system performance are evaluated. The results show that the optimal comprehensive COP and annual hot water production (mDHW) of the TPE-LTES system are 3.59 and 3110 tons, respectively. Then, the comprehensive exergy efficiency of the TPE-LTES system owns 48.93 % higher than that of the heat pump unit. Furthermore, the optimal life-cycle cost (LCC) and life-cycle CO2 emissions (LCCE) of the TPE-LTES system are 708,073 CNY and 575,512.79 kg, respectively. Moreover, with constant discharge pressure, the evaporative superheat can be preferentially increased to reduce the system LCC and LCCE. Finally, the comprehensive COP and exergy efficiency of the system can be improved by increasing the inlet water temperature, while the increasing inlet water flow rate is the least desirable. This work is helpful to promote the research and application of latent heat storage unit integrated into air source heat pump.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Investigating 4E analyses and multi-objective optimization of a novel data center compression/ejection transcritical CO2 cooling system
    Qin, Xiang
    Shen, Aoqi
    Duan, Hongxin
    Liu, Hongzhi
    Wang, Dingbiao
    Liu, Heyu
    Wang, Guanghui
    APPLIED THERMAL ENGINEERING, 2025, 264
  • [2] Data-driven multi-objective optimization design of transcritical CO2 heat pump
    Li, Enteng
    Xu, Yingjie
    Xie, Xiaodong
    Fan, Wei
    Huagong Jinzhan/Chemical Industry and Engineering Progress, 2020, 39 (05): : 1657 - 1666
  • [3] Multi-objective optimization on a heat exchanger network retrofit with a heat pump and analysis of CO2 emissions control
    Kang, Lixia
    Liu, Yongzhong
    APPLIED ENERGY, 2015, 154 : 696 - 708
  • [4] Bi-objective optimization of transcritical CO2 heat pump systems
    Okasha, Ahmed
    Mueller, Norbert
    Deb, Kalyanmoy
    ENERGY, 2022, 247
  • [5] Thermal economy analysis and multi-objective optimization of a small CO2 transcritical pumped thermal electricity storage system
    Liu, Zhongyan
    Zhang, Hao
    Jin, Xu
    Zheng, Shuang
    Li, Ruijie
    Guan, Hongwei
    Shao, Jiawei
    ENERGY CONVERSION AND MANAGEMENT, 2023, 293
  • [6] Thermodynamic analysis and multi-objective optimization of a transcritical CO2 waste heat recovery system for cruise ship application
    Zhang, Qiang
    Luo, Zewei
    Zhao, Yongjie
    Pavel, Suniaikin
    ENERGY CONVERSION AND MANAGEMENT, 2021, 227 (227)
  • [7] Thermodynamic analysis and multi-objective optimization of a waste heat recovery system with a combined supercritical/transcritical CO2 cycle
    Qin, Lei
    Xie, Gongnan
    Ma, Yuan
    Li, Shulei
    ENERGY, 2023, 265
  • [8] Multi-factor coupling optimization of heat recovery effectiveness in a transcritical CO2 heat pump
    Zheng, Zecan
    Song, Yulong
    Wang, Shouguo
    Yang, Xu
    Cao, Feng
    Yang, Tao
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2024, 167 : 201 - 213
  • [9] Performance study of transcritical CO2 heat pump integrated with ejector and latent thermal energy storage for space heating
    Zhang, Dongwei
    Fang, Chenglei
    Qin, Xiang
    Li, Hang
    Liu, He
    Wu, Xuehong
    ENERGY CONVERSION AND MANAGEMENT, 2022, 268
  • [10] 4E analyses and multi-objective optimization of cascade refrigeration cycles with heat recovery system
    Mofrad, Kamyar Golbaten
    Zandi, Sina
    Salehi, Gholamreza
    Manesh, Mohammad Hasan Khoshgoftar
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2020, 19