Tear film dynamics of a new soft contact lens

被引:2
作者
Buch, John [1 ]
Riederer, Donald [1 ]
Scales, Charles [1 ]
Xu, Jie [1 ]
机构
[1] Johnson & Johnson Vis Care, Jacksonville, FL 32224 USA
关键词
contact lenses; randomised controlled study; senofilcon A contact lens; tear film stability; OPTICAL-QUALITY; LIPID LAYER; THICKNESS;
D O I
10.1111/opo.13169
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To present the objective metrics from a study that evaluated the clinical performance of a senofilcon A contact lens, both with and without a new manufacturing technique.Methods: This was a single-site, five-visit, controlled, randomised, subject-masked, 2 x 2 crossover study (May-August 2021) with a 2-week lens dispensing period (bilateral wear) and weekly follow-up visits. Healthy adult (18-39 years), habitual spherical silicone hydrogel contact lens wearers were included. The High-definition (HD) Analyzer (TM) was used to objectively measure the lens-on-eye optical system resulting from the study lenses at 1-week follow-up. Measurements assessed were vision break-up time (VBUT), modulation transfer function (MTF) cutoff, Strehl ratio (SR), potential visual acuity (PVA) for 100% contrast and objective scatter index (OSI).Results: Of the 50 enrolled participants, 47 (94.0%) were randomly assigned to one of the two possible lens wear sequences (test/control or control/test) and dispensed at least one study lens. The estimated odds ratio of VBUT > 10 s was 1.582 (95% confidence interval [CI]: 1.009 to 2.482) in test versus control lens. The least squares mean difference estimates of MTF cutoff, SR and PVA for 100% contrast between test versus control lens were 2.243 (95% CI: 0.012 to 4.475), 0.011 (95% CI: -0.002 to 0.023) and 0.073 (95% CI: -0.001 to 0.147), respectively. The estimated ratio of median OSI between test versus control lens was 0.887 (95% CI: 0.727 to 1.081). The test lens demonstrated superiority over the control lens with respect to VBUT and MTF cutoff. No serious adverse events were reported; eight adverse events (three ocular, five non-ocular) were indicated by six participants during the study.Conclusion: The test lens demonstrated an increased probability of having a longer VBUT (>10 s). Future studies may be designed to assess the efficacy and long-term use of the test lens in a larger population.
引用
收藏
页码:1070 / 1078
页数:9
相关论文
共 47 条
[1]  
Abusharha AA, 2017, CLIN OPTOM, V9, P133, DOI 10.2147/OPTO.S142718
[2]  
Ahmed SF., VISUAL FUNCTION DIGI
[3]  
[Anonymous], VIS LAUNCH HD AN NEX
[4]   The Assessment of Visual Function and Functional Vision [J].
Bennett, Christopher R. ;
Bex, Peter J. ;
Bauer, Corinna M. ;
Merabet, Lotfi B. .
SEMINARS IN PEDIATRIC NEUROLOGY, 2019, 31 :30-40
[5]  
Buch J., 2016, CONT LENS SPECTR, V31, P34
[6]   Visual performance after the deterioration of retinal image quality: induced forward scattering using Bangerter foils and fog filters [J].
Castro-Torres, Jose J. ;
Martino, Francesco ;
Casares-Lopez, Miriam ;
Ortiz-Peregrina, Sonia ;
Ortiz, Carolina .
BIOMEDICAL OPTICS EXPRESS, 2021, 12 (05) :2902-2918
[7]   Ultrahigh-Resolution Measurement by Optical Coherence Tomography of Dynamic Tear Film Changes on Contact Lenses [J].
Chen, Qi ;
Wang, Jianhua ;
Tao, Aizhu ;
Shen, Meixiao ;
Jiao, Shuliang ;
Lu, Fan .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (04) :1988-1993
[8]  
Fosso TJ., IMPROVE CONTACT LENS
[9]   Effects of Blink Rate on Tear Film Optical Quality Dynamics with Different Soft Contact Lenses [J].
Garcia-Montero, Maria ;
Rico-del-Viejo, Laura ;
Martinez-Alberquilla, Irene ;
Luis Hernandez-Verdejo, Jose ;
Lorente-Velazquez, Amalia ;
Madrid-Costa, David .
JOURNAL OF OPHTHALMOLOGY, 2019, 2019
[10]   Corneal thickness change induced by dozing while wearing hydrogel and silicone hydrogel lenses [J].
Hamano, Hikaru ;
Maeda, Naoyuki ;
Hamano, Takashi ;
Mitsunaga, Sachiko ;
Kotani, Setsuko .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2008, 34 (01) :56-60