Comparison of paraspinal muscle composition measurements using IDEAL fat-water and T2-weighted MR images

被引:2
|
作者
Masi, Sara [1 ]
Rye, Meaghan [1 ]
Roussac, Alexa [1 ]
Naghdi, Neda [1 ]
Rosenstein, Brent [1 ]
Bailey, Jeannie F. [2 ]
Fortin, Maryse [1 ,3 ,4 ]
机构
[1] Concordia Univ, Dept Hlth Kinesiol & Appl Physiol, 7141 Sherbrooke St W,SP 165-29, Montreal, PQ H4B 1R6, Canada
[2] Univ Calif San Francisco, Dept Orthopaed Surg, San Francisco, CA USA
[3] Concordia Univ, PERFORM Ctr, Montreal, PQ, Canada
[4] Ctr Rech Interdisciplinaire Readaptat CRIR, Montreal, PQ, Canada
关键词
Fatty infiltration; IDEAL; Multifidus; Erector spinae; Psoas major; Paraspinal muscle; Magnetic resonance imaging; LOW-BACK-PAIN; OLDER-ADULTS; PSOAS MAJOR; RELIABILITY; MORPHOLOGY; AGREEMENT; SYMPTOMS; SIZE;
D O I
10.1186/s12880-023-00992-w
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeThe purpose of this study was to evaluate the agreement between paraspinal muscle composition measurements obtained from fat-water images using % fat-signal fraction (%FSF) in comparison to those obtained from T2-weighted magnetic resonance images (MRI) using a thresholding method.MethodsA sample of 35 subjects (19 females, 16 males; 40.26 +/- 11.3 years old) was selected from a cohort of patients with chronic low back pain (LBP). Axial T2-weighted and IDEAL (Lava-Flex, 2 echo sequence) fat and water MR images were obtained using a 3.0 Tesla GE scanner. Multifidus, erector spinae, and psoas major muscle composition measurements were acquired bilaterally at L4-L5 and L5-S1 using both imaging sequences and related measurement methods. All measurements were obtained by the same rater, with a minimum of 7 days between each method. Intra-class correlation coefficients (ICCs) were calculated to assess intra-rater reliability. Pearson Correlation and Bland-Altman 95% limits of agreement were used to assess the agreement between both measurement methods.ResultsThe intra-rater reliability was excellent for all measurements with ICCs varying between 0.851 and 0.997. Strong positive correlations indicating a strong relationship between composition measurements were obtained from fat-water and T2-weighted images for bilateral multifidus and erector spinae muscles at both spinal levels and the right psoas major muscle at L4-L5, with correlation coefficient r ranging between 0.67 and 0.92. Bland-Altman plots for bilateral multifidus and erector spinae muscles at both levels revealed excellent agreement between the two methods, however, systematic differences between both methods were evident for psoas major fat measurements.ConclusionOur findings suggest that utilizing fat-water and T2-weighted MR images are comparable for quantifying multifidus and erector spinae muscle composition but not of the psoas major. While this suggests that both methods could be used interchangeably for the multifidus and erector spinae, further evaluation is required to expand and confirm our findings to other spinal levels.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Computer Aided Detection of Cavernous Malformation in T2-weighted Brain MR Images
    Wang, Huiquan
    Xu, Hongming
    Ahmed, S. Nizam
    Mandal, Mrinal
    2016 IEEE HEALTHCARE INNOVATION POINT-OF-CARE TECHNOLOGIES CONFERENCE (HI-POCT), 2016, : 101 - 104
  • [42] Vacuum disc: frequency of high signal intensity on T2-weighted MR images
    Schweitzer, ME
    El-Noueam, KI
    SKELETAL RADIOLOGY, 1998, 27 (02) : 83 - 86
  • [43] MR of Toxoplasma encephalitis: Signal characteristics on T2-weighted images and pathologic correlation
    Brightbill, TC
    Post, MJD
    Hensley, GT
    Ruiz, A
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1996, 20 (03) : 417 - 422
  • [44] MR IMAGING OF BRAIN METASTASES (1)T2-WEIGHTED IMAGES AS A SCREENING SEQUENCE
    HOSTEN, N
    SCHORNER, W
    SCHUBEUS, P
    FELIX, R
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1990, 153 (03): : 321 - 326
  • [45] MALIGNANT LESIONS OF THE LIVER IDENTIFIED ON T1-WEIGHTED BUT NOT T2-WEIGHTED MR-IMAGES AT 1.5 T
    SEMELKA, RC
    BAGLEY, AS
    BROWN, ED
    KROEKER, MA
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (03): : 315 - 318
  • [46] EFFECT OF MULTISLICE INTERFERENCE ON IMAGE-CONTRAST IN T2-WEIGHTED AND T1-WEIGHTED MR IMAGES
    KUCHARCZYK, W
    CRAWLEY, AP
    KELLY, WM
    HENKELMAN, RM
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1988, 9 (03) : 443 - 451
  • [47] Utility of frequency-selective fat saturation T2-weighted MR images for the detection of joint effusion in the temporomandibular joint
    Tanaka, T
    Morimoto, Y
    Masumi, S
    Tominaga, K
    Ohba, T
    DENTOMAXILLOFACIAL RADIOLOGY, 2002, 31 (05) : 305 - 312
  • [48] Fully automated segmentation of wrist bones on T2-weighted fat-suppressed MR images in early rheumatoid arthritis
    Wong, Lun Matthew
    Shi, Lin
    Xiao, Fan
    Griffith, James Francis
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2019, 9 (04) : 579 - 589
  • [49] T2-Weighted Liver MRI Using the MultiVane Technique at 3T: Comparison with Conventional T2-Weighted MRI
    Kang, Kyung A.
    Kim, Young Kon
    Kim, EunJu
    Jeong, Woo Kyoung
    Choi, Dongil
    Lee, Won Jae
    Jung, Sin-Ho
    Baek, Sun-Young
    KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (05) : 1038 - 1046
  • [50] Contrast Enhancement by Combining T1-and T2-Weighted Structural Brain MR Images
    Misaki, Masaya
    Savitz, Jonathan
    Zotev, Vadim
    Phillips, Raquel
    Yuan, Han
    Young, Kymberly D.
    Drevets, Wayne C.
    Bodurka, Jerzy
    MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (06) : 1609 - 1620