Modified Fukuda stepping motion assessment of young healthy adults using portable inertial measurement units

被引:2
作者
Miwa, Toru [1 ,2 ]
Yasuda, Tomohisa [3 ]
Kouga, Teppei [1 ]
Sunami, Kishiko [1 ]
机构
[1] Osaka Metropolitan Univ, Dept Otolaryngol Head & Neck Surg, 1-4-3 Asahi-machi, Abeno-ku, Osaka 5458585, Japan
[2] Kyoto Univ, Grad Sch Med, Dept Otolaryngol Head & Neck Surg, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 6068507, Japan
[3] Yasuda ENT Clin, 1-1-1 TakarOachi, Katsusika-ku, Tokyo 1240005, Japan
关键词
Foulage test; Inertial measurement unit; Micro-electromechanical system; Modified fukuda stepping test; Multivariable regression analysis; Sensing technologies; Six-axis motion sensor; ACCELEROMETRY; ORIENTATION; BALANCE; GAIT; EYE;
D O I
10.1016/j.heliyon.2023.e15018
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Currently, vestibular rehabilitation approaches used to monitor body position and movement during rehabilitation training require specialized equipment or rely on clinician observation. Thus, a simpler position-sensing approach that can be used to monitor movement during vestibular rehabilitation is required. This study used wearable motion sensors with built-in ac-celerometers and gyrometers to assess movement in adults. We explored stepping patterns in adults using this motion-sensing system. Six healthy adults (men, age 27.3 +/- 5.8 years) under-went a modified Fukuda stepping test (Foulage test [FT]) while wearing a six-axis motion sensor (accelerometer: X-axis, Y-axis, Z-axis; gyrometer: X-axis, Y-axis, Z-axis) positioned at the head, thorax, and lumbar spine. For motion sensor parameters, we calculated the root mean square (RMS), autocorrelation coefficient (AC), power spectrum (PS) of the AC, and Euler angles from the six-axis motion sensor. For the FT parameters, the FT value, step variance, and theta values were calculated. Data were analyzed, and multivariable regression analysis was performed using the FT value, step variance, and theta value as the dependent variables to investigate their influence on dynamic equilibrium. The explanatory variables included the motion sensor parameters, RMS, AC, and PS. Our results suggested that almost no head and lumbar spine movement occurred while stepping with eyes open. Contrastingly, the head and lumbar spine swayed with eyes closed. This accelerometric and gyroscopic device is easy to use, does not require specialized equipment, and can be used to analyze performance in the modified Fukuda stepping test in clinical practice. Inertial sensors have many advantages over other sensing technologies.
引用
收藏
页数:11
相关论文
共 32 条
  • [1] The Fukuda Stepping Test Is Influenced by a Concurrent Cognitive Task and Step Height in Healthy Young Adults: A Descriptive Study
    Grostern, Jessica
    Lajoie, Yves
    Paquet, Nicole
    PHYSIOTHERAPY CANADA, 2021, 73 (04) : 322 - 328
  • [2] Assessment of walking quality by using Inertial Measurement Units
    Saito, K.
    Zecca, M.
    Sessa, S.
    Lin, Z.
    Bartolomeo, L.
    Cosentino, S.
    Petersen, K.
    Ishii, H.
    Ikai, T.
    Takanishi, A.
    2012 FIRST INTERNATIONAL CONFERENCE ON INNOVATIVE ENGINEERING SYSTEMS (ICIES), 2012, : 13 - 18
  • [3] Assessment of varus thrust using inertial measurement units
    Murro, Millissia A.
    Mihy, Julien A.
    Wagatsuma, Mayumi
    Hafer, Jocelyn F.
    CLINICAL BIOMECHANICS, 2025, 122
  • [4] Gait Characteristics Based on Shoe-Type Inertial Measurement Units in Healthy Young Adults during Treadmill Walking
    Lee, Myeounggon
    Youm, Changhong
    Noh, Byungjoo
    Park, Hwayoung
    SENSORS, 2020, 20 (07)
  • [5] Gait Variability Using Waist- and Ankle-Worn Inertial Measurement Units in Healthy Older Adults
    Rantalainen, Timo
    Karavirta, Laura
    Pirkola, Henrikki
    Rantanen, Taina
    Linnamo, Vesa
    SENSORS, 2020, 20 (10)
  • [6] Riding Motion Capture System Using Inertial Measurement Units with Contact Constraints
    Maruyama, Tsubasa
    Tada, Mitsunori
    Toda, Haruki
    INTERNATIONAL JOURNAL OF AUTOMATION TECHNOLOGY, 2019, 13 (04) : 506 - 516
  • [7] Validation of Pelvis and Trunk Range of Motion as Assessed Using Inertial Measurement Units
    Ali, Farwa
    Hogen, Cecilia A.
    Miller, Emily J.
    Kaufman, Kenton R.
    BIOENGINEERING-BASEL, 2024, 11 (07):
  • [8] Reliability and Validity of a Wearable Inertial Sensor System for Gait Assessment in Healthy Young Adults
    Hou, Ying
    Wang, Shujia
    Li, Jinping
    Komal, Sana
    Li, Ke
    2021 14TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, BIOMEDICAL ENGINEERING AND INFORMATICS (CISP-BMEI 2021), 2021,
  • [9] Proposed Mobility Assessments with Simultaneous Full-Body Inertial Measurement Units and Optical Motion Capture in Healthy Adults and Neurological Patients for Future Validation Studies: Study Protocol
    Warmerdam, Elke
    Romijnders, Robbin
    Geritz, Johanna
    Elshehabi, Morad
    Maetzler, Corina
    Otto, Jan Carl
    Reimer, Maren
    Stuerner, Klarissa
    Baron, Ralf
    Paschen, Steffen
    Beyer, Thorben
    Dopcke, Denise
    Eiken, Tobias
    Ortmann, Hendrik
    Peters, Falko
    von der Recke, Felix
    Riesen, Moritz
    Rohwedder, Gothia
    Schaade, Anna
    Schumacher, Maike
    Sondermann, Anton
    Maetzler, Walter
    Hansen, Clint
    SENSORS, 2021, 21 (17)
  • [10] Cervical Coupling Motion Characteristics in Healthy People Using a Wireless Inertial Measurement Unit
    Kim, Hyunho
    Shin, Sang-Hoon
    Kim, Jeong-Kyun
    Park, Young-Jae
    Oh, Hwan-Sup
    Park, Young-Bae
    EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE, 2013, 2013