Heart Rate Extraction From Neonatal Near-Infrared Spectroscopy Signals

被引:1
作者
Hakimi, Naser [1 ,2 ]
Horschig, Jorn M. M. [1 ]
Alderliesten, Thomas [2 ]
Bronkhorst, Mathijs [1 ]
Floor-Westerdijk, Marianne J. J. [1 ]
van Bel, Frank [2 ]
Colier, Willy N. J. M. [1 ]
Dudink, Jeroen [2 ]
机构
[1] Artinis Med Syst BV, NL-6662 PW Elst, Netherlands
[2] Univ Med Ctr Utrecht, Wilhelmina Childrens Hosp, Dept Neonatol, NL-3584 EA Utrecht, Netherlands
关键词
Cerebral oxygenation; heart rate (HR); near-infrared spectroscopy (NIRS); neonates; signal quality assessment; OXYGENATION; ALGORITHM; INFANTS; TISSUE; BRAIN; LIFE;
D O I
10.1109/TIM.2023.3295015
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Near-infrared spectroscopy (NIRS) intensity signals provide useful additional physiological information, of which the most prominent one is the pulsatile fluctuation by heartbeats. This allows for the extraction of heart rate (HR), one of the primary clinical indicators of health in neonates. In this study, we propose a novel algorithm, NIRS HR (NHR), for extracting HR from NIRS signals acquired from neonates admitted to the neonatal intensive care unit (NICU). After parental consent, we synchronously recorded NIRS at 100 Hz and reference HR (RHR) at 1 Hz, from ten newborn infants (gestational age = 38 +/- 5 weeks; 3092 +/- 990 g). The NHR algorithm consists of two main parts. The first part includes four steps implemented once on the whole NIRS measurement: preprocessing; HR frequency bandwidth determination; interquartile range (IQR) computation; and segmentation. The second part includes three steps implemented on each signal segment: motion artifact detection, signal quality assessment, and HR computation. We compared the NHR algorithm with two existing algorithms. The results showed that the proposed NHR algorithm provides a significantly (p < 0.05) higher correlation (r = 99.5%) and lower Bland-Altman ratio (BAR = 3.6%) between the extracted and RHRs, compared to the existing algorithms. Extracting HR from NIRS in a clinical setting of critically ill neonates admitted to neonatal intensive care is feasible. With NIRS and HR combined in a single monitoring system, it is possible to have a perfectly time-synced integrated analysis of cerebral hemodynamics, as well as systemic hemodynamics and autonomic nervous system tone.
引用
收藏
页数:13
相关论文
共 54 条
  • [1] Skin care for preterm and term neonates
    Afsar, F. S.
    [J]. CLINICAL AND EXPERIMENTAL DERMATOLOGY, 2009, 34 (08) : 855 - 858
  • [2] Heart Rate Variability in Neonates with Hypoxic Ischemic Encephalopathy
    Aliefendioglu, Didem
    Dogru, Tolga
    Albayrak, Meryem
    DibekMisirlioglu, Emine
    Sanli, Cihat
    [J]. INDIAN JOURNAL OF PEDIATRICS, 2012, 79 (11) : 1468 - 1472
  • [3] MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES
    ALTMAN, DG
    BLAND, JM
    [J]. JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) : 307 - 317
  • [4] Heart Rate Monitoring in Newborn Babies: A Systematic Review
    Anton, Oana
    Fernandez, Ramon
    Rendon-Morales, Elizabeth
    Aviles-Espinosa, Rodrigo
    Jordan, Harriet
    Rabe, Heike
    [J]. NEONATOLOGY, 2019, 116 (03) : 199 - 210
  • [5] Heart rate variability as possible marker of brain damage in neonates with hypoxic ischemic encephalopathy: a systematic review
    Bersani, Iliana
    Piersigilli, Fiammetta
    Gazzolo, Diego
    Campi, Francesca
    Savarese, Immacolata
    Dotta, Andrea
    Tamborrino, Pietro Paolo
    Auriti, Cinzia
    Di Mambro, Corrado
    [J]. EUROPEAN JOURNAL OF PEDIATRICS, 2021, 180 (05) : 1335 - 1345
  • [6] A portable near infrared spectroscopy system for bedside monitoring of newborn brain
    Bozkurt, Alper
    Rosen, Arye
    Rosen, Harel
    Onaral, Banu
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2005, 4 (1)
  • [7] Autonomic nervous system in newborns: a review based on heart rate variability
    Cardoso, Sandra
    Silva, Marta Joao
    Guimares, Hercilia
    [J]. CHILDS NERVOUS SYSTEM, 2017, 33 (07) : 1053 - 1063
  • [8] A Thermal Effects-Based Method for Void Detection in Concrete Face Rockfill Dams
    Chen, Jiang
    Song, Yin
    Xiong, Feng
    Ai, Ting
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [9] Video-Based Heart Rate Measurement: Recent Advances and Future Prospects
    Chen, Xun
    Cheng, Juan
    Song, Rencheng
    Liu, Yu
    Ward, Rabab
    Wang, Z. Jane
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2019, 68 (10) : 3600 - 3615
  • [10] Heart Rate Variability in the Perinatal Period: A Critical and Conceptual Review
    Chiera, Marco
    Cerritelli, Francesco
    Casini, Alessandro
    Barsotti, Nicola
    Boschiero, Dario
    Cavigioli, Francesco
    Corti, Carla G.
    Manzotti, Andrea
    [J]. FRONTIERS IN NEUROSCIENCE, 2020, 14