Evaluation of Different Cannulation Strategies for Aortic Arch Surgery Using a Cardiovascular Numerical Simulator

被引:2
作者
De Lazzari, Beatrice [1 ]
Capoccia, Massimo [2 ,3 ]
Cheshire, Nicholas J. J. [4 ]
Rosendahl, Ulrich P. P. [4 ]
Badagliacca, Roberto [5 ]
De Lazzari, Claudio [6 ,7 ]
机构
[1] Foro Italico Univ Rome, Human Movement & Sport Sci, I-00147 Rome, Italy
[2] Leeds Teaching Hosp NHS Trust, Leeds Gen Infirm, Leeds LS1 3EX, England
[3] Univ Strathclyde, Dept Biomed Engn, Glasgow G4 0NW, Scotland
[4] Royal Brompton Hosp, Aort Ctr, London SW3 6NP, England
[5] Sapienza Univ Rome, Dept Clin Internal Anesthesiol & Cardiovasc Sci, I-00147 Rome, Italy
[6] CNR, Inst Clin Physiol IFC CNR, I-00185 Rome, Italy
[7] Teaching Univ Geomed, Fac Med, GA-0114 Tbilisi, Georgia
来源
BIOENGINEERING-BASEL | 2023年 / 10卷 / 01期
关键词
aortic surgery; aortic arch; three-way cannulation approach; carotid artery perfusion; pressure-volume loop; lumped-parameter model; software simulation; cardiovascular modelling;
D O I
10.3390/bioengineering10010060
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Aortic disease has a significant impact on quality of life. The involvement of the aortic arch requires the preservation of blood supply to the brain during surgery. Deep hypothermic circulatory arrest is an established technique for this purpose, although neurological injury remains high. Additional techniques have been used to reduce risk, although controversy still remains. A three-way cannulation approach, including both carotid arteries and the femoral artery or the ascending aorta, has been used successfully for aortic arch replacement and redo procedures. We developed circuits of the circulation to simulate blood flow during this type of cannulation set up. The CARDIOSIM (c) cardiovascular simulation platform was used to analyse the effect on haemodynamic and energetic parameters and the benefit derived in terms of organ perfusion pressure and flow. Our simulation approach based on lumped-parameter modelling, pressure-volume analysis and modified time-varying elastance provides a theoretical background to a three-way cannulation strategy for aortic arch surgery with correlation to the observed clinical practice.
引用
收藏
页数:22
相关论文
共 94 条
[81]   Numerical simulation of cardiovascular dynamics with different types of VAD assistance [J].
Shi, Yubing ;
Korakianitis, Theodosios ;
Bowles, Christopher .
JOURNAL OF BIOMECHANICS, 2007, 40 (13) :2919-2933
[82]   Numerical simulation of cardiovascular dynamics with left heart failure and in-series pulsatile ventricular assist device [J].
Shi, Yubing ;
Korakianitis, Theodosios .
ARTIFICIAL ORGANS, 2006, 30 (12) :929-948
[83]   Impeller-pump model derived from conservation laws applied to the simulation of the cardiovascular system coupled to heart-assist pumps [J].
Shi, Yubing ;
Korakianitis, Theodosios .
COMPUTERS IN BIOLOGY AND MEDICINE, 2018, 93 :127-138
[84]   Computational modelling and evaluation of cardiovascular response under pulsatile impeller pump support [J].
Shi, Yubing ;
Brown, Alistair G. ;
Lawford, Patricia V. ;
Arndt, Andreas ;
Nuesser, Peter ;
Hose, D. Rodney .
INTERFACE FOCUS, 2011, 1 (03) :320-337
[85]   Review of Zero-D and 1-D Models of Blood Flow in the Cardiovascular System [J].
Shi, Yubing ;
Lawford, Patricia ;
Hose, Rodney .
BIOMEDICAL ENGINEERING ONLINE, 2011, 10
[86]   Current status and recommendations for use of the frozen elephant trunk technique: a position paper by the Vascular Domain of EACTS [J].
Shrestha, Malakh ;
Bachet, Jean ;
Bavaria, Joseph ;
Carrel, Thierry P. ;
De Paulis, Ruggero ;
Di Bartolomeo, Roberto ;
Etz, Christian D. ;
Grabenwoeger, Martin ;
Grimm, Michael ;
Haverich, Axel ;
Jakob, Heinz ;
Martens, Andreas ;
Mestres, Carlos A. ;
Pacini, Davide ;
Resch, Tim ;
Schepens, Marc ;
Urbanski, Paul P. ;
Czerny, Martin .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2015, 47 (05) :759-769
[87]   Total aortic arch replacement with the elephant trunk technique: single-centre 30-year results [J].
Shrestha, Malakh ;
Martens, Andreas ;
Krueger, Heike ;
Maeding, Illona ;
Ius, Fabio ;
Fleissner, Felix ;
Haverich, Axel .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2014, 45 (02) :289-296
[88]   Non-Newtonian Endothelial Shear Stress Simulation: Does It Matter? [J].
Thondapu, Vikas ;
Shishikura, Daisuke ;
Dijkstra, Jouke ;
Zhu, Shuang J. ;
Revalor, Eve ;
Serruys, Patrick W. ;
van Gaal, William J. ;
Poon, Eric K. W. ;
Ooi, Andrew ;
Barlis, Peter .
FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
[89]   DEEP HYPOTHERMIC SYSTEMIC CIRCULATORY ARREST AND CONTINUOUS RETROGRADE CEREBRAL PERFUSION FOR SURGERY OF AORTIC-ARCH ANEURYSM [J].
UEDA, Y ;
MIKI, S ;
KUSUHARA, K ;
OKITA, Y ;
TAHATA, T ;
YAMANAKA, K .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1992, 6 (01) :36-41
[90]   Carotid artery cannulation in aortic surgery [J].
Urbanski, Paul P. ;
Lenos, Aristidis ;
Lindemann, Yvonne ;
Weigang, Ernst ;
Zacher, Michael ;
Diegeler, Anno .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 132 (06) :1398-1403