Evaluation of Different Cannulation Strategies for Aortic Arch Surgery Using a Cardiovascular Numerical Simulator

被引:2
作者
De Lazzari, Beatrice [1 ]
Capoccia, Massimo [2 ,3 ]
Cheshire, Nicholas J. J. [4 ]
Rosendahl, Ulrich P. P. [4 ]
Badagliacca, Roberto [5 ]
De Lazzari, Claudio [6 ,7 ]
机构
[1] Foro Italico Univ Rome, Human Movement & Sport Sci, I-00147 Rome, Italy
[2] Leeds Teaching Hosp NHS Trust, Leeds Gen Infirm, Leeds LS1 3EX, England
[3] Univ Strathclyde, Dept Biomed Engn, Glasgow G4 0NW, Scotland
[4] Royal Brompton Hosp, Aort Ctr, London SW3 6NP, England
[5] Sapienza Univ Rome, Dept Clin Internal Anesthesiol & Cardiovasc Sci, I-00147 Rome, Italy
[6] CNR, Inst Clin Physiol IFC CNR, I-00185 Rome, Italy
[7] Teaching Univ Geomed, Fac Med, GA-0114 Tbilisi, Georgia
来源
BIOENGINEERING-BASEL | 2023年 / 10卷 / 01期
关键词
aortic surgery; aortic arch; three-way cannulation approach; carotid artery perfusion; pressure-volume loop; lumped-parameter model; software simulation; cardiovascular modelling;
D O I
10.3390/bioengineering10010060
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Aortic disease has a significant impact on quality of life. The involvement of the aortic arch requires the preservation of blood supply to the brain during surgery. Deep hypothermic circulatory arrest is an established technique for this purpose, although neurological injury remains high. Additional techniques have been used to reduce risk, although controversy still remains. A three-way cannulation approach, including both carotid arteries and the femoral artery or the ascending aorta, has been used successfully for aortic arch replacement and redo procedures. We developed circuits of the circulation to simulate blood flow during this type of cannulation set up. The CARDIOSIM (c) cardiovascular simulation platform was used to analyse the effect on haemodynamic and energetic parameters and the benefit derived in terms of organ perfusion pressure and flow. Our simulation approach based on lumped-parameter modelling, pressure-volume analysis and modified time-varying elastance provides a theoretical background to a three-way cannulation strategy for aortic arch surgery with correlation to the observed clinical practice.
引用
收藏
页数:22
相关论文
共 94 条
[1]   Leukocyte filtration to decrease the number of adherent leukocytes in the cerebral microcirculation after a period of deep hypothermic circulatory arrest [J].
Alaoja, Hanna ;
Niemela, Eija ;
Anttila, Vesa ;
Dahlbacka, Sebastian ;
Makela, Jussi ;
Kiviluoma, Kai ;
Laurila, Paivi ;
Kaakinen, Timo ;
Juvonen, Tatu .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 132 (06) :1339-U14
[2]  
[Anonymous], 2011, CARDIOSIM WEBSITE OR
[3]   Antegrade cerebral perfusion with cold blood: A 13-year experience [J].
Bachet, J ;
Guilmet, D ;
Goudot, B ;
Dreyfuss, GD ;
Delentdecker, P ;
Brodaty, D ;
Dubois, C .
ANNALS OF THORACIC SURGERY, 1999, 67 (06) :1874-1878
[4]  
BACHET J, 1991, J THORAC CARDIOV SUR, V102, P85
[5]   Open repair techniques in the aortic arch are still superior [J].
Bachet, Jean .
ANNALS OF CARDIOTHORACIC SURGERY, 2018, 7 (03) :328-344
[6]   RETROGRADE CEREBRAL PERFUSION DOES NOT PERFUSE THE BRAIN IN NONHUMAN-PRIMATES [J].
BOECKXSTAENS, CJ ;
FLAMENG, WJ .
ANNALS OF THORACIC SURGERY, 1995, 60 (02) :319-328
[7]   EXTENSIVE AORTIC REPLACEMENT USING ELEPHANT TRUNK PROSTHESIS [J].
BORST, HG ;
WALTERBUSCH, G ;
SCHAPS, D .
THORACIC AND CARDIOVASCULAR SURGEON, 1983, 31 (01) :37-40
[8]   Mathematical modeling of cardiac function to evaluate clinical cases in adults and children [J].
Bozkurt, Selim .
PLOS ONE, 2019, 14 (10)
[9]   Real-Time Continuous Monitoring of Cerebral Blood Flow Autoregulation Using Near-Infrared Spectroscopy in Patients Undergoing Cardiopulmonary Bypass [J].
Brady, Kenneth ;
Joshi, Brijen ;
Zweifel, Christian ;
Smielewski, Peter ;
Czosnyka, Marek ;
Easley, R. Blaine ;
Hogue, Charles W., Jr. .
STROKE, 2010, 41 (09) :1951-1956
[10]  
Capoccia M., 2018, J BIOMED ENG INFORM, V4, P8, DOI [10.5430/jbei.v4n2p, DOI 10.5430/JBEI.V4N2P]