Clinical longevity of direct and indirect posterior resin composite restorations: An updated systematic review and meta-analysis

被引:22
作者
Josic, Uros [1 ]
D'Alessandro, Carlo [1 ]
Miletic, Vesna [2 ]
Maravic, Tatjana [1 ]
Mazzitelli, Claudia [1 ]
Jacimovic, Jelena [3 ]
Sorrentino, Roberto [4 ]
Zarone, Fernando [4 ]
Mancuso, Edoardo [1 ]
Delgado, Antonio H. S. [5 ,6 ]
Breschi, Lorenzo [1 ,7 ]
Mazzoni, Annalisa [1 ]
机构
[1] Univ Bologna, Dept Biomed & Neuromotor Sci, Bologna, Italy
[2] Univ Sydney, Fac Med & Hlth, Sydney Dent Sch, Sydney 2145, Australia
[3] Univ Belgrade, Sch Dent Med, Cent Lib, Belgrade, Serbia
[4] Univ Federico II Naples, Dept Neurosci Reprod & Odontostomatol Sci, Div Prosthodont & Digital Dent, Naples, Italy
[5] Egas Moniz Ctr Interdisciplinary Res CiiEM, P-2829511 Almada, Portugal
[6] UCL Eastman Dent Inst, Div Biomat & Tissue Engn, London, England
[7] Univ Bologna, Dept Biomed & Neuromotor Sci, DIBINEM, Via San Vitale 59, I-40125 Bologna, Italy
关键词
Longevity; Composite restoration; Systematic review; TOOTH WEAR; INLAYS; TRIAL; PERFORMANCE; STRENGTH; FAILURE; MONOMER; DENTIN; TEETH;
D O I
10.1016/j.dental.2023.10.009
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To answer the PICO(S) question: Is there a difference in clinical longevity between direct and indirect resin composite restorations placed on permanent posterior teeth?Data: Randomized controlled clinical trials (RCTs) investigating direct and indirect resin composite restorations in posterior permanent teeth were considered.Sources: Several electronic databases were searched, with no language or date restrictions. The revised Cochrane Collaboration's tool for assessing risk of bias (RoB-2) was used to analyze the studies; meta-analyses were run and the certainty of evidence was assessed by the GRADE tool. A subgroup meta-analysis was performed for resin composite restorations placed on posterior worn dentition. Study selection: Twenty-three articles were included in qualitative synthesis, while 8 studies were used for meta -analyses. According to the RoB-2 tool, 5 studies were ranked as "low risk", 7 had "some concerns", while 11 papers were rated as "high risk" of bias. There were no statistically significant differences in short-term (p = 0.27; RR=1.54, 95% CI [0.72, 3.33]), mediumterm (p = 0.27; RR=1.87, 95% CI [0.61, 5.72]) and long-term longevity (p = 0.86; RR=0.95, 95% CI [0.57, 1.59]). The choice of restorative technique had no influence on short-term survival of resin composite restorations placed on worn dentition (p = 0.13; RR=0.46, 95% CI [0.17, 1.25]). The certainty of evidence was rated as "very low".Conclusions: Direct and indirect resin composite restorations may show similar clinical longevity in posterior region, regardless of the observation period or substrate (wear-affected and non-affected dentition). The very low quality of evidence suggests that more long-term RCTs are needed to confirm our results.
引用
收藏
页码:1085 / 1094
页数:10
相关论文
共 79 条
  • [71] A randomized clinical trial of class II composite restorations using direct and semidirect techniques
    Torres, Carlos Rocha Gomes
    Mailart, Mariane Cintra
    Crastechini, Erica
    Feitosa, Fernanda Alves
    Esteves, Stella Renato Machado
    Di Nicolo, Rebeca
    Borges, Alessandra Buhler
    [J]. CLINICAL ORAL INVESTIGATIONS, 2020, 24 (02) : 1053 - 1063
  • [72] Two-year performance of CAD/CAM fabricated resin composite inlay restorations: A randomized controlled clinical trial
    Tunac, Ayse T.
    Celik, Esra U.
    Yasa, Bilal
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2019, 31 (06) : 627 - 638
  • [73] Direct resin composite inlays/onlays: an 11 year follow-up
    van Dijken, JWV
    [J]. JOURNAL OF DENTISTRY, 2000, 28 (05) : 299 - 306
  • [74] A 6-YEAR EVALUATION OF A DIRECT COMPOSITE RESIN INLAY ONLAY SYSTEM AND GLASS-IONOMER CEMENT COMPOSITE RESIN SANDWICH RESTORATIONS
    VANDIJKEN, JWV
    [J]. ACTA ODONTOLOGICA SCANDINAVICA, 1994, 52 (06) : 368 - 376
  • [75] A comparative study of the microtensile bond strength and microstructural differences between sclerotic and Normal dentine after surface pretreatment
    Wang, Jinhua
    Song, Weijian
    Zhu, Lei
    Wei, Xin
    [J]. BMC ORAL HEALTH, 2019, 19 (01)
  • [76] DIRECT COMPOSITE INLAYS VERSUS CONVENTIONAL COMPOSITE RESTORATIONS - 3-YEAR CLINICAL-RESULTS
    WASSELL, RW
    WALLS, AWG
    MCCABE, JF
    [J]. BRITISH DENTAL JOURNAL, 1995, 179 (09) : 343 - 349
  • [77] Direct composite inlays versus conventional composite restorations: 5-year follow-up
    Wassell, RW
    Walls, AWG
    McCabe, JF
    [J]. JOURNAL OF DENTISTRY, 2000, 28 (06) : 375 - 382
  • [78] Proximal wear rates by tooth position of resin composite restorations
    Wendt, SL
    Ziemiecki, TL
    Leinfelder, KF
    [J]. JOURNAL OF DENTISTRY, 1996, 24 (1-2) : 33 - 39
  • [79] Direct composite resin fillings versus amalgam fillings for permanent posterior teeth
    Worthington, Helen, V
    Khangura, Sara
    Seal, Kelsey
    Mierzwinski-Urban, Monika
    Veitz-Keenan, Analia
    Sahrmann, Philipp
    Schmidlin, Patrick Roger
    Davis, Dell
    Iheozor-Ejiofor, Zipporah
    Rasines Alcaraz, Maria Graciela
    [J]. COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2021, (08):