Effects of the applied voltage on electroactive microbial biofilm viability and hydrogen production in a recalcitrant organic waste-fed single-chamber membrane-free microbial electrolysis cell performance

被引:29
作者
Ndayisenga, Fabrice [1 ,2 ,3 ]
Yu, Zhisheng [1 ,2 ,3 ]
Wang, Bobo [1 ,3 ]
Zhou, Dandan [4 ]
机构
[1] Univ Chinese Acad Sci, Coll Resources & Environm, 19 A Yuquan Rd, Beijing 100049, Peoples R China
[2] Weiqiao UCAS Sci & Technol Pk, Binzhou Inst Technol, Binzhou 256606, Shandong, Peoples R China
[3] RCEES IMCAS UCAS Joint Lab Microbial Technol Envir, Beijing 100085, Peoples R China
[4] Northeast Normal Univ, Sch Environm, Changchun 130117, Peoples R China
关键词
Hydrogen production; Biofilm viability; Electrochemical impedance spectroscopy; Applied voltage; Microbial electrolysis cells; Agricultural straw wastes; WATER TREATMENT; ELECTRIC-CURRENT; H-2; PRODUCTION; FERMENTATION; IMPACT; GENERATION; RECOVERY; ENERGY; FIELD;
D O I
10.1016/j.cej.2023.144002
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The microbial electrolysis cell (MEC) is a future clean technology with a wide range of applications in energy recycling fields, particularly for hydrogen production. Applied voltage governs the electrochemically active microbial activities in MEC and further affects hydrogen production. Therefore, this study investigated the im-pacts of the applied voltages on MEC performance and anodic biofilm viability during the biotransformation of straw waste biomass into green hydrogen energy in an anaerobic environment. The results revealed that the COD removal efficiency and bioH2 yield increased with the augmentation of the applied voltage and beyond 0.8 V started decreasing. Among the performed protocols MEC0.8 depicted the best performance with a maximum H2 production of 6.017 mmoles H2/g-COD which was-28.2 % and-9.8 % higher than that of MEC0.5 and MEC1.0 respectively. Moreover, it also achieved a maximum COD removal of 73.4% and a coulombic efficiency (CE) of 68.4%. Consistently, the anodic biofilm viability and bacterial cell shape in the MECs performed with 0.5 V and 0.8 V were less affected but largely damaged in a high potential operated protocol (MEC1.0), suggesting that the mixed electroactive consortia were so sensitive to high potentials. Furthermore, MEC1.0 displayed a high charge transfer resistance of 16.06 & omega; which was-22.1 %, and-73.7 % higher than that of MEC0.8, and MEC0.5 respectively. Based on our novel study's results, the optimal applied voltage for the best performance of MEC was 0.8 V; and this information will be a pillar for future MEC operations prior to maintaining its industrial practice.
引用
收藏
页数:10
相关论文
共 54 条
[51]  
[杨金水 Yang Jinshui], 2010, [生物技术通报, Biotechnology Bulletin], P185
[52]   Co-substrate strategy for improved power production and chlorophenol degradation in a microbial fuel cell [J].
Yu, Yang ;
Ndayisenga, Fabrice ;
Yu, Zhisen ;
Zhao, Mingyue ;
Lay, Chyi-How ;
Zhou, Dandan .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2019, 44 (36) :20312-20322
[53]   Microbial electrolysis cells turning to be versatile technology: Recent advances and future challenges [J].
Zhang, Yifeng ;
Angelidaki, Irini .
WATER RESEARCH, 2014, 56 :11-25
[54]   Response to Comment on "Intimate Coupling of Photocatalysis and Biodegradation for Degrading Phenol Using Different Light Types: Visible Light vs UV Light" [J].
Zhou, Dandan ;
Shi, Junlong ;
Dong, Shuangshi ;
Huo, Mingxin .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2015, 49 (21) :13077-13078