Lab-in-syringe automated protein precipitation and salting-out homogenous liquid-liquid extraction coupled online to UHPLC-MS/MS for the determination of beta-blockers in serum

被引:13
|
作者
Yildirim, Sercan [1 ,2 ]
Fikarova, Katerina [2 ]
Pilarova, Veronika [2 ]
Novakova, Lucie [2 ]
Solich, Petr [2 ]
Horstkotte, Burkhard [2 ]
机构
[1] Karadeniz Tech Univ, Fac Pharm, Dept Analyt Chem, Farabi St, TR-61080 Trabzon, Turkiye
[2] Charles Univ Prague, Fac Pharm Hradec Kralove, Dept Analyt Chem, Akademika Heyrovskeho 1203, Hradec Kralove 50005, Czech Republic
关键词
Centrifugation-less protein precipitation; Serum; Beta-blockers; Lab-in-syringe automation; Salting-out homogenous liquid-liquid  extraction; HUMAN WHOLE-BLOOD; SAMPLE PREPARATION; PLASMA; DRUGS; PHARMACOKINETICS; MICROEXTRACTION; BIOANALYSIS;
D O I
10.1016/j.aca.2023.340966
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sample preparation method involving tandem implementation of protein precipitation and salting-out homogenous liquid-liquid extraction was developed for the determination of beta-blockers in serum. The entire procedure was automated using a computer-controlled syringe pump following the Lab-In-Syringe approach. It is based on the denaturation of serum proteins with acetonitrile followed by salt-induced phase separation upon which the proteins accumulate as a compact layer at the interphase of the solutions. The extract is then separated and diluted in-syringe before being submitted to online coupled UHPLC-MS/MS. A 1 mL glass syringe containing a small stir bar for solution mixing at up to 3000 rpm, was used to deal with sample volumes as small as 100 mu L. A sample throughput of 7 h-1 was achieved by performing the chromatographic run and sample preparation procedure in parallel. Linear working ranges were obtained for all analytes between 5 and 100 ng mL-1, with LOD values ranging from 0.4 to 1.5 ng mL-1. Accuracy values in the range of 88.2-106% and high precision of <11% RSD suggest applicability for routine analysis that can be further improved using deuterated standards.
引用
收藏
页数:10
相关论文
共 21 条
  • [21] Extension of the Temporal Window for the Determination of Alpha-Methylthiofentanyl and Thiofentanyl in Rat Urine by Monitoring the Metabolite Norfentanyl Using Online Solid-Phase Extraction (SPE) Coupled with Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry (UHPLC-MS/MS)