Detection of solid and subsolid pulmonary nodules with lung MRI: performance of UTE, T1 gradient-echo, and single-shot T2 fast spin echo

被引:6
作者
Sanchez, Felipe [1 ]
Tyrrell, Pascal N. [2 ]
Cheung, Patrick [3 ]
Heyn, Chinthaka [1 ]
Graham, Simon [4 ]
Poon, Ian [3 ]
Ung, Yee [3 ]
Louie, Alexander [3 ]
Tsao, May [3 ]
Oikonomou, Anastasia [1 ]
机构
[1] Univ Toronto, Sunnybrook Hlth Sci Ctr, Dept Med Imaging, 2075 Bayview Ave, Toronto, ON M4N 3M5, Canada
[2] Univ Toronto, Inst Med Sci, Dept Med Imaging, Dept Stat Sci, 263 McCaul St, Toronto, ON M5T 1WT, Canada
[3] Univ Toronto, Sunnybrook Hlth Sci Ctr, Dept Radiat Oncol, 2075 Bayview Ave, Toronto, ON M4N 3M5, Canada
[4] Univ Toronto, Phys Sci Platform Sunnybrook Res Inst, Dept Med Biophys, 2075 Bayview Ave, Toronto, ON M4N 3M5, Canada
关键词
Lung MRI; Pulmonary nodule; UTE; VIBE; HASTE; COMPUTED-TOMOGRAPHY; CANCER; CT; RADIATION; PROBABILITY; SEQUENCES; STANDARD; PET/MR; TRIAL;
D O I
10.1186/s40644-023-00531-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
BackgroundAlthough MRI is a radiation-free imaging modality, it has historically been limited in lung imaging due to inherent technical restrictions. The aim of this study is to explore the performance of lung MRI in detecting solid and subsolid pulmonary nodules using T1 gradient-echo (GRE) (VIBE, Volumetric interpolated breath-hold examination), ultrashort time echo (UTE) and T2 Fast Spin Echo (HASTE, Half fourier Single-shot Turbo spin-Echo).MethodsPatients underwent a lung MRI in a 3 T scanner as part of a prospective research project. A baseline Chest CT was obtained as part of their standard of care. Nodules were identified and measured on the baseline CT and categorized according to their density (solid and subsolid) and size (> 4 mm/ <= 4 mm). Nodules seen on the baseline CT were classified as present or absent on the different MRI sequences by two thoracic radiologists independently. Interobserver agreement was determined using the simple Kappa coefficient. Paired differences were compared using nonparametric Mann-Whitney U tests. The McNemar test was used to evaluate paired differences in nodule detection between MRI sequences.ResultsThirty-six patients were prospectively enrolled. One hundred forty-nine nodules (100 solid/49 subsolid) with mean size 10.8 mm (SD = 9.4) were included in the analysis. There was substantial interobserver agreement (k = 0.7, p = 0.05).Detection for all nodules, solid and subsolid nodules was respectively; UTE: 71.8%/71.0%/73.5%; VIBE: 61.6%/65%/55.1%; HASTE 72.4%/72.2%/72.7%. Detection rate was higher for nodules > 4 mm in all groups: UTE 90.2%/93.4%/85.4%, VIBE 78.4%/88.5%/63.4%, HASTE 89.4%/93.8%/83.8%. Detection of lesions <= 4 mm was low for all sequences. UTE and HASTE performed significantly better than VIBE for detection of all nodules and subsolid nodules (diff = 18.4 and 17.6%, p = < 0.01 and p = 0.03, respectively). There was no significant difference between UTE and HASTE. There were no significant differences amongst MRI sequences for solid nodules.ConclusionsLung MRI shows adequate performance for the detection of solid and subsolid pulmonary nodules larger than 4 mm and can serve as a promising radiation-free alternative to CT.
引用
收藏
页数:9
相关论文
共 33 条
  • [1] Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening
    Aberle, Denise R.
    Adams, Amanda M.
    Berg, Christine D.
    Black, William C.
    Clapp, Jonathan D.
    Fagerstrom, Richard M.
    Gareen, Ilana F.
    Gatsonis, Constantine
    Marcus, Pamela M.
    Sicks, JoRean D.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2011, 365 (05) : 395 - 409
  • [2] Screening for lung cancer: Does MRI have a role?
    Biederer, Juergen
    Ohno, Yoshiharu
    Hatabu, Hiroto
    Schiebler, Mark L.
    van Beek, Edwin J. R.
    Vogel-Claussen, Jens
    Kauczor, Hans-Ulrich
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2017, 86 : 353 - 360
  • [3] Detection of Small Pulmonary Nodules with Ultrashort Echo Time Sequences in Oncology Patients by Using a PET/MR System
    Burris, Nicholas S.
    Johnson, Kevin M.
    Larson, Peder E. Z.
    Hope, Michael D.
    Nagle, Scott K.
    Behr, Spencer C.
    Hope, Thomas A.
    [J]. RADIOLOGY, 2016, 278 (01) : 239 - 246
  • [4] Pulmonary Nodules in Patients with Primary Malignancy: Comparison of Hybrid PET/MR and PET/CT Imaging
    Chandarana, Hersh
    Heacock, Laura
    Rakheja, Rajan
    DeMello, Linda R.
    Bonavita, John
    Block, Tobias K.
    Geppert, Christian
    Babb, James S.
    Friedman, Kent P.
    [J]. RADIOLOGY, 2013, 268 (03) : 874 - 881
  • [5] MR Imaging of Pulmonary Nodules: Detection Rate and Accuracy of Size Estimation in Comparison to Computed Tomography
    Cieszanowski, Andrzej
    Lisowska, Antonina
    Dabrowska, Marta
    Korczynski, Piotr
    Zukowska, Malgorzata
    Grudzinski, Ireneusz P.
    Pacho, Ryszard
    Rowinski, Olgierd
    Krenke, Rafal
    [J]. PLOS ONE, 2016, 11 (06):
  • [6] Update of MR Imaging for Evaluation of Lung Cancer
    Ciliberto, Mario
    Kishida, Yuji
    Seki, Shinichiro
    Yoshikawa, Takeshi
    Ohno, Yoshiharu
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 2018, 56 (03) : 437 - +
  • [7] Comparative evaluation of non-contrast CAIPIRINHA-VIBE 3T-MRI and multidetector CT for detection of pulmonary nodules: In vivo evaluation of diagnostic accuracy and image quality
    Dewes, Patricia
    Frellesen, Claudia
    Al-Butmeh, Firas
    Albrecht, Moritz H.
    Scholtz, Jan-Erik
    Metzger, Sarah C.
    Lehnert, Thomas
    Vogl, Thomas J.
    Wichmann, Julian L.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (01) : 193 - 198
  • [8] UK Lung Cancer RCT Pilot Screening Trial: baseline findings from the screening arm provide evidence for the potential implementation of lung cancer screening
    Field, J. K.
    Duffy, S. W.
    Baldwin, D. R.
    Whynes, D. K.
    Devaraj, A.
    Brain, K. E.
    Eisen, T.
    Gosney, J.
    Green, B. A.
    Holemans, J. A.
    Kavanagh, T.
    Kerr, K. M.
    Ledson, M.
    Lifford, K. J.
    McRonald, F. E.
    Nair, A.
    Page, R. D.
    Parmar, M. K. B.
    Rassl, D. M.
    Rintoul, R. C.
    Screaton, N. J.
    Wald, N. J.
    Weller, D.
    Williamson, P. R.
    Yadegarfar, G.
    Hansell, D. M.
    [J]. THORAX, 2016, 71 (02) : 161 - 170
  • [9] Patient Size-Specific Analysis of Dose Indexes From CT Lung Cancer Screening
    Fujii, Keisuke
    McMillan, Kyle
    Bostani, Maryam
    Cagnon, Christopher
    McNitt-Gray, Michael
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 208 (01) : 144 - 149
  • [10] Lung cancer probability in patients with CT-detected pulmonary nodules: a prespecifi ed analysis of data from the NELSON trial of low-dose CT screening
    Horeweg, Nanda
    van Rosmalen, Joost
    Heuvelmans, Marjolein A.
    van der Aalst, Carlijn M.
    Vliegenthart, Rozemarijn
    Scholten, Ernst Th
    ten Haaf, Kevin
    Nackaerts, Kristiaan
    Lammers, Jan-Willem J.
    Weenink, Carla
    Groen, Harry J.
    van Ooijen, Peter
    de Jong, Pim A.
    de Bock, Geertruida H.
    Mali, Willem
    de Koning, Harry J.
    Oudkerk, Matthijs
    [J]. LANCET ONCOLOGY, 2014, 15 (12) : 1332 - 1341