Learning curve for robotic assisted total knee arthroplasty: our experience with imageless hand-held Navio system

被引:12
|
作者
Vaidya, Narendra [1 ]
Gadekar, Anup [1 ]
Agrawal, Varun O. [1 ]
Jaysingani, Tanmay N. [1 ]
机构
[1] Lokmanya Hosp, Dept Orthopaed, Pune, Maharashtra, India
关键词
Robotic assisted total knee arthroplasty; Learning curve; Operative time; Technology; POSTOPERATIVE ALIGNMENT; PATIENT SATISFACTION; REPLACEMENT; OUTCOMES;
D O I
10.1007/s11701-022-01423-8
中图分类号
R61 [外科手术学];
学科分类号
摘要
The main purpose of this study was to determine the learning curve of Robotic assisted Total Knee Arthroplasty surgery through assessment of operative time and comparison with that of conventional jig based Total Knee Arthroplasty. The study included our first 75 Robotic assisted Total Knee Arthroplasty and 25 randomly selected conventional jig-based Total knee arthroplasty from June 2017 to December 2017. The 75 cases were divided into 3 groups of 25 consecutive cases. The mean of operative time for each phase and total time was compared between the 3 groups and with the mean of total time for conventional jig based group. In our experience, Robotic assisted Total Knee arthroplasty was associated with a learning curve of approximately 25 cases. The mean for Registration phase of Group A (1st set of 25 cases) was 6.12 min (SD 1.8 min), group B (2nd set of 25 cases) was 4.46 min (SD 0.79 min) and group C (3rd set of 25 cases) was 4.17 min (SD 0.59 min). The mean for Planning phase of group A was 5.08 min (SD 1.01 min), group B was 4.04 min (SD 0.37 min) and group C was 4.01 min (SD 0.35 min). The mean for Cutting Phase of group A was 28.22 min (SD 6.24 min), group B was 22.49 min (SD 0.79 min) and group C was 22.36 min (SD 0.88 min). The mean for total time of group A was 39.42 min (SD 8.02), group B was 31 min (SD 1.22 min), group C was 30.53 min (SD 1.14 min) and conventional group was 30.54 min (SD 1.14 min). On comparing the Registration phase (Group A vs B, p < 0.001; Group B vs C, p 0.14; Group A vs C, p < 0.001), Planning phase (Group A vs B, p < 0.001; Group B vs C, p 0.75; Group A vs C, p < 0.001), Cutting phase (Group A vs B, p < 0.001; Group B vs C, p 0.58; Group A vs C, p < 0.001) and Total time (Group A vs B, p < 0.001; Group B vs C, p 0.74; Group A vs C, p < 0.001; Group A vs Conventional, p < 0.001; Group B vs Conventional, p 0.17, Group C vs Conventional, p 0.99), the results showed that the inflection point for learning curve in our hands was 25 cases. The learning curve and increased operation theatre time are likely to be major barrier in widespread acceptance of robotic technology amongst arthroplasty surgeons. We, in our experience can say that the learning curve was approximately 25 cases. The results of this study will help the arthroplasty surgeons in accepting this technology and achieve better outcomes.
引用
收藏
页码:393 / 403
页数:11
相关论文
共 50 条
  • [1] Learning curve for robotic assisted total knee arthroplasty: our experience with imageless hand-held Navio system
    Narendra Vaidya
    Anup Gadekar
    Varun O. Agrawal
    Tanmay N. Jaysingani
    Journal of Robotic Surgery, 2023, 17 : 393 - 403
  • [2] A systematic review of imageless hand-held robotic-assisted knee arthroplasty: learning curve, accuracy, functional outcome and survivorship
    Clement, Nicholas D.
    Al-Zibari, Marwan
    Afzal, Irrum
    Deehan, David J.
    Kader, Deiary
    EFORT OPEN REVIEWS, 2020, 5 (05) : 319 - 326
  • [3] Accuracy and learning curve of imageless robotic-assisted total knee arthroplasty
    Bosco, Francesco
    Rovere, Giuseppe
    Burgio, Carmelo
    Bue, Giorgia Lo
    Cobisi, Claudio Domenico
    Via, Riccardo Giai
    Lucenti, Ludovico
    Camarda, Lawrence
    JOURNAL OF ORTHOPAEDICS, 2025, 66 : 77 - 83
  • [4] Comparing an imageless hand-held robotic-assisted system versus conventional technique for component positioning and early clinical outcomes in total knee arthroplasty
    Hasegawa, Masahiro
    Hattori, Yoshio
    Naito, Yohei
    Tone, Shine
    Sudo, Akihiro
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2024, 20 (01):
  • [5] The accuracy of a hand-held navigation system in total knee arthroplasty
    Loh, Bryan
    Chen, Jerry Yongqiang
    Yew, Andy Khye Soon
    Pang, Hee Nee
    Tay, Darren Keng Jin
    Chia, Shi-Lu
    Lo, Ngai Nung
    Yeo, Seng Jin
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2017, 137 (03) : 381 - 386
  • [6] Imageless robotic handpiece-assisted total knee arthroplasty: a learning curve analysis of surgical time and alignment accuracy
    Savov, Peter
    Tuecking, Lars-Rene
    Windhagen, Henning
    Ehmig, Jonathan
    Ettinger, Max
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (12) : 2119 - 2128
  • [7] Imageless robotic-assisted total knee arthroplasty accurately restores the radiological alignment with a short learning curve: a randomized controlled trial
    Thiengwittayaporn, Satit
    Uthaitas, Pinyong
    Senwiruch, Chaipipathn
    Hongku, Natthapong
    Tunyasuwanakul, Revit
    INTERNATIONAL ORTHOPAEDICS, 2021, 45 (11) : 2851 - 2858
  • [8] Learning curve analysis of robotic-assisted total knee arthroplasty with a Chinese surgical system
    Haoran Zhang
    Xizhuang Bai
    Huisheng Wang
    Zhiyong Zhu
    Xi Li
    Journal of Orthopaedic Surgery and Research, 18
  • [9] Learning curve analysis of robotic-assisted total knee arthroplasty with a Chinese surgical system
    Zhang, Haoran
    Bai, Xizhuang
    Wang, Huisheng
    Zhu, Zhiyong
    Li, Xi
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [10] Initial Experience with the NAVIO Robotic-Assisted Total Knee Replacement-Coronal Alignment Accuracy and the Learning Curve
    Collins, Kade
    Agius, Paul A.
    Fraval, Andrew
    Petterwood, Josh
    JOURNAL OF KNEE SURGERY, 2022, 35 (12) : 1295 - 1300