Reagentless Vis-NIR Spectroscopy Point-of-Care for Feline Total White Blood Cell Counts

被引:1
作者
Barroso, Teresa Guerra [1 ]
Queiros, Carla [2 ]
Monteiro-Silva, Filipe [3 ]
Santos, Filipe [3 ]
Gregorio, Antonio Hugo [4 ]
Martins, Rui Costa [3 ]
机构
[1] CESPU, Univ Inst Hlth Sci IUCS, TOXRUN One Hlth Toxicol Res Unit 1H, P-4585116 Gandra, Portugal
[2] Univ Porto, Fac Sci, LAQV REQUIMTE, R Campo Alegre, P-4169007 Porto, Portugal
[3] INESC TEC Inst Syst & Comp Engn Technol & Sci Camp, Rua Dr Roberto Frias, P-4200465 Porto, Portugal
[4] Anicura CHV Vet Hosp Ctr, R Manuel Pinto de Azevedo 118, P-4100320 Porto, Portugal
来源
BIOSENSORS-BASEL | 2024年 / 14卷 / 01期
关键词
point-of-care; spectroscopy; white blood cells; artificial intelligence; INFRARED-SPECTROSCOPY; FOLLOW-UP; PERFORMANCE; DIAGNOSIS; MATRIX; RAMAN;
D O I
10.3390/bios14010053
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Spectral point-of-care technology is reagentless with minimal sampling (<10 mu L) and can be performed in real-time. White blood cells are non-dominant in blood and in spectral information, suffering significant interferences from dominant constituents such as red blood cells, hemoglobin and billirubin. White blood cells of a bigger size can account for 0.5% to 22.5% of blood spectra information. Knowledge expansion was performed using data augmentation through the hybridization of 94 real-world blood samples into 300 synthetic data samples. Synthetic data samples are representative of real-world data, expanding the detailed spectral information through sample hybridization, allowing us to unscramble the spectral white blood cell information from spectra, with correlations of 0.7975 to 0.8397 and a mean absolute error of 32.25% to 34.13%; furthermore, we achieved a diagnostic efficiency between 83% and 100% inside the reference interval (5.5 to 19.5 x 10(9) cell/L), and 85.11% for cases with extreme high white blood cell counts. At the covariance mode level, white blood cells are quantified using orthogonal information on red blood cells, maximizing sensitivity and specificity towards white blood cells, and avoiding the use of non-specific natural correlations present in the dataset; thus, the specifity of white blood cells spectral information is increased. The presented research is a step towards high-specificity, reagentless, miniaturized spectral point-of-care hematology technology for Veterinary Medicine.
引用
收藏
页数:16
相关论文
共 54 条
[1]  
Agbaria AH, 2020, ANALYST, V145, P6955, DOI [10.1039/d0an00752h, 10.1039/D0AN00752H]
[2]   Point-of-care Vis-SWNIR spectroscopy towards reagent-less hemogram analysis [J].
Barroso, T. G. ;
Ribeiro, L. ;
Gregorio, H. ;
Santos, F. ;
Martins, R. C. .
SENSORS AND ACTUATORS B-CHEMICAL, 2021, 343
[3]   Detection of BCG bacteria using a magnetoresistive biosensor: A step towards a fully electronic platform for tuberculosis point-of-care detection [J].
Barroso, Teresa G. ;
Martins, Rui C. ;
Fernandes, Elisabete ;
Cardoso, Susana ;
Rivas, Jose ;
Freitas, Paulo P. .
BIOSENSORS & BIOELECTRONICS, 2018, 100 :259-265
[4]   Point-of-Care Using Vis-NIR Spectroscopy for White Blood Cell Count Analysis [J].
Barroso, Teresa Guerra ;
Ribeiro, Lenio ;
Gregorio, Hugo ;
Monteiro-Silva, Filipe ;
dos Santos, Filipe Neves ;
Martins, Rui Costa .
CHEMOSENSORS, 2022, 10 (11)
[5]  
Brown M, 2000, CLIN CHEM, V46, P1221
[6]  
Burns D.M., 2001, HDB NEAR INFRARED AN
[7]  
Burton A.G., 2018, Textbook of Small Animal Emergency Medicine, P405, DOI [10.1002/9781119028994.ch64, DOI 10.1002/9781119028994.CH64]
[8]   A Preliminary Study of FTIR Spectroscopy as a Potential Non-Invasive Screening Tool for Pediatric Precursor B Lymphoblastic Leukemia [J].
Chaber, Radoslaw ;
Kowal, Aneta ;
Jakubczyk, Pawel ;
Arthur, Christopher ;
Lach, Kornelia ;
Wojnarowska-Nowak, Renata ;
Kusz, Krzysztof ;
Zawlik, Izabela ;
Paszek, Sylwia ;
Cebulski, Jozef .
MOLECULES, 2021, 26 (04)
[9]   White Blood Cell Counts Reference Methodology [J].
Chabot-Richards, Devon S. ;
George, Tracy I. .
CLINICS IN LABORATORY MEDICINE, 2015, 35 (01) :11-+
[10]   On the feasibility of Vis-NIR spectroscopy and machine learning for real time SARS-CoV-2 detection [J].
Coelho, Bruno Fonseca Oliveira ;
Nunes, Savio Luiz Pereira ;
de Franca, Chirles Araujo ;
Costa, Daniel dos Santos ;
do Carmo, Rodrigo Feliciano ;
Prates, Ricardo Menezes ;
Simas Filho, Eduardo Furtado ;
Ramos, Rodrigo Pereira .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2024, 308