Simultaneous determination of uric acid, xanthine, and caffeine in human urine samples using nickel ferrite/reduced graphene oxide modified electrode

被引:7
|
作者
Man, Nguyen Quang [1 ,2 ]
Tu, Nguyen Thi Thanh [3 ]
Vu, Ho Xuan Anh [1 ]
Quyen, Nguyen Duc Vu [1 ]
Phong, Nguyen Hai [1 ]
Tuyen, Tran Ngoc [1 ]
Van Thanh Son, Le [4 ]
Son, Le Vu Truong [4 ]
Hoan, Nguyen Thi Vuong [5 ]
To, Thuy Chau [6 ]
Khieu, Dinh Quang [1 ]
机构
[1] Hue Univ, Univ Sci, Hue 530000, Vietnam
[2] Hue Univ, Univ Pharm & Med, Hue 530000, Vietnam
[3] Van Lang Univ, Fac Appl Technol, Sch Engn & Technol, Ho Chi Minh 700000, Vietnam
[4] Univ Danang, Univ Educ & Sci, Da Nang 550000, Vietnam
[5] Quy Nhon Univ, Fac Nat Sci, Quy Nhon 820000, Vietnam
[6] Thu Dau Mot Univ, Thu Dau Mot 590000, Vietnam
关键词
SENSITIVE ELECTROCHEMICAL SENSOR; VOLTAMMETRIC DETERMINATION; MAGNETIC-PROPERTIES; FERRITE NIFE2O4; SIMPLE ROUTE; HYPOXANTHINE; ACETAMINOPHEN; THEOPHYLLINE; PERFORMANCE; FABRICATION;
D O I
10.1007/s10854-022-09449-2
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This work describes the synthesis of nickel ferrite/reduced graphene oxide (FN/rGO) and the simultaneous determination of uric acid (UA), xanthine (XT), and caffeine (CF) by using the resultant FN/rGO-modified electrode. The material was characterized by means of X-ray diffraction, scanning electron microscopy, energy-dispersive X-ray microscopy (mapping energy-dispersive X-Ray), adsorption/desorption isotherms of nitrogen, vibrating sample magnetometry, and Raman spectroscopy. The obtained composite with a large surface area comprises reduced-graphene-oxide layers and highly dispersed nickel-ferrite nanoparticles. This composite possesses significant magnetization saturation with a soft magnetic property. The electrocatalytic activity of FN/rGO was studied toward the oxidation of one important purine, UA, and two oxypurines, XT and CF. The electrode successfully separates the voltammetric signals of the three analytes in a trinary mixture and is employed for their simultaneous determination. The peak current varies linearly with the increase of UA, XT, and CF concentration in a range of 4.0-21.5 mu M with detection limits of 1.3, 1.6, and 1.4 mu M for UA, XT, and CF, respectively. The practical application of the modified electrode was demonstrated by simultaneously determining the concentrations of UA, XT, and CF in urine samples with expectable recoveries.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] A selective determination of levodopa in the presence of ascorbic acid and uric acid using a glassy carbon electrode modified with reduced graphene oxide
    Soon-Young Yi
    Jong-Hyeok Lee
    Hun-Gi Hong
    Journal of Applied Electrochemistry, 2014, 44 : 589 - 597
  • [23] The Electroxidation of Uric Acid at Zinc Oxide/Reduced Graphene Oxide Composites Modified Electrode
    Yusoff, Farhanini
    Sang, Lee Pak
    Saleh, Noorashikin Md
    3RD INTERNATIONAL SCIENCES, TECHNOLOGY & ENGINEERING CONFERENCE (ISTEC) 2018 - MATERIAL CHEMISTRY, 2018, 2031
  • [24] Electrochemical deposition of gold nanoparticles on reduced graphene oxide modified glassy carbon electrode for simultaneous determination of levodopa, uric acid and folic acid
    Benvidi, Ali
    Dehghani-Firouzabadi, Afsaneh
    Mazloum-Ardakani, Mohammad
    Mirjalili, Bi-Bi Fatemeh
    Zare, Reza
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 736 : 22 - 29
  • [25] Simultaneous and sensitive determination of ascorbic acid, dopamine, uric acid, and tryptophan with silver nanoparticles-decorated reduced graphene oxide modified electrode
    Kaur, Balwinder
    Pandiyan, Thangarasu
    Satpati, Biswarup
    Srivastava, Rajendra
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2013, 111 : 97 - 106
  • [26] Simultaneous Determination of Theophylline and Caffeine Using Poly(L-phenylalanine)-Reduced Graphene Oxide Modified Glassy Carbon Electrode
    Zhang, Lin
    Wang, Ting
    Fan, Xinxia
    Deng, Dongmei
    Li, Yuanyuan
    Yan, Xiaoxia
    Luo, Liqiang
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (04): : 1 - 11
  • [27] Stable determination of paracetamol in the presence of uric acid in human urine sample using melamine grafted graphene modified electrode
    Kesavan, Srinivasan
    John, S. Abraham
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 760 : 6 - 14
  • [28] SIMULTANEOUS ELECTROCHEMICAL DETECTION OF ASCORBIC ACID, DOPAMINE, AND URIC ACID AT MAGNETIC NANOPARTICLES/REDUCED GRAPHENE OXIDE MODIFIED ELECTRODE
    Rosli, Azleen Rashidah Mohd
    Yusoff, Farhanini
    Loh, Saw Hong
    Yusoff, Hanis Mohd
    Jamil, Muhammad Mahadi Abdul
    Shamsudin, Shazrul Hasry
    JURNAL TEKNOLOGI-SCIENCES & ENGINEERING, 2021, 83 (03): : 85 - 92
  • [29] SENSITIVE ELECTROCHEMICAL DETERMINATION OF ETHAMBUTOL IN PHARMACEUTICAL FORMULATION AND HUMAN URINE AT NICKEL NANOPARTICLES/ELECTROCHEMICALLY REDUCED GRAPHENE OXIDE MODIFIED ELECTRODE
    Mekassa, Brihanu
    Baker, Priscilla G. L.
    Chandravanshi, Bhagwan Singh
    Tessema, Merid
    BULLETIN OF THE CHEMICAL SOCIETY OF ETHIOPIA, 2019, 33 (02) : 215 - 228
  • [30] Direct electrodeposition of reduced graphene oxide on carbon fiber electrode for simultaneous determination of ascorbic acid, dopamine and uric acid
    Yang, Beibei
    Wang, Huiwen
    Du, Jiao
    Fu, Yunzhi
    Yang, Ping
    Du, Yukou
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2014, 456 : 146 - 152