Development and Usability of an Inexpensive and Reusable Phantom for Ultrasound-Guided Needle Cannulation

被引:0
|
作者
Linnet, Jacob [1 ,2 ]
Obinah, Magnus P. [3 ]
Madsen, Mikkel H. [4 ]
Moller, Magnus M. [1 ]
Russell, Lene [5 ]
Ekelund, Kim [1 ,6 ]
Svendsen, Morten B. [1 ,7 ]
Thinggaard, Ebbe [1 ,8 ]
机构
[1] Copenhagen Acad Med Educ & Simulat, Med Educ & Simulat, Copenhagen, Denmark
[2] Univ Copenhagen, Hlth & Med Sci, Copenhagen, Denmark
[3] Copenhagen Univ Hosp, Herlev & Gentofte Hosp, Plast Surg, Copenhagen, Denmark
[4] Copenhagen Univ Hosp, Amager & Hvidovre Hosp, Anesthesiol & Intens Care, Copenhagen, Denmark
[5] Copenhagen Univ Hosp, Herlev & Gentofte Hosp, Anesthesiol & Intens Care, Copenhagen, Denmark
[6] Copenhagen Univ Hosp, Rigshosp Hosp, Anesthesiol & Intens Care, Copenhagen, Denmark
[7] Univ Copenhagen, Comp Sci, Copenhagen, Denmark
[8] Univ Copenhagen, Clin Med, Copenhagen, Denmark
关键词
emergency medicine; anesthesiology; simulation trainer; ultrasound phantom; peripheral vein catheter; ultrasound guided; PROCEDURAL SKILLS; ACCESS;
D O I
10.7759/cureus.52583
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Ultrasound -guided peripheral venous catheter placement (UG-PVCP) is a key skill for establishing intravenous access, especially in patients with anatomical challenges. Ultrasound is highly operatordependent, and it is essential to ensure a sufficient level of competence when educating healthcare professionals. Competence can be acquired through simulation -based training (SBT) using phantoms or simulators. We developed a phantom for SBT, and in this study, we explore the phantom's usability and technical fidelity. Methods Novices with no experience in UG-PVCP and experts who routinely performed the procedure were asked to perform three ultrasound -guided catheter placement attempts on the phantom. Afterward, they were asked to complete a usability questionnaire consisting of 14 questions exploring the usability and fidelity of the phantom. Results Fifty-seven participants were included in the study: 29 novices and 28 experts. When assessing positive questions about the frequency of use, ease of use, integration of functionality, quickness to learn, and confidence level, the study showed a median score of 4 to 5 out of 5 in the two groups. The median was 1 to 2 out of 5 for negative questions assessing cumbersomeness, unnecessary complexity, and model inconsistency. In an additional comment textbox, one participant mentioned that the cannulation did not feel realistic but that it was good for cannulation practice. Conclusions We believe the phantom is suitable for an educational curriculum since it shows a high level of usability, scoring high on positive questions while scoring low on negative questions, and having high functional fidelity.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Ultrasound-guided needle biopsy of the breast
    Staren, ED
    O'Neill, TP
    SURGERY, 1999, 126 (04) : 629 - 634
  • [42] Dominant hand operating probe vs needle: a comparison study of ultrasound-guided needle placement in phantom models
    Johnston, D. F.
    Stafford, M.
    ANAESTHESIA, 2015, 70 (08) : 969 - 974
  • [43] Bronchoscopic transesophageal ultrasound-guided needle aspiration: An alternative to the conventional transesophageal ultrasound-guided needle aspiration technique
    Oki, Masahide
    Saka, Hideo
    Kitagawa, Chiyoe
    Sato, Shinji
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 139 (06): : 1659 - 1661
  • [44] Reusable Phantom With Feedback Signal for Ultrasound Needle Tip Control
    Tsui, Ban C. H.
    Tsui, Jenkin
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2011, 36 (06) : 630 - 631
  • [45] Evaluation of ultrasound-guided radial artery cannulation in children
    Ganesh, Arjunan
    Kaye, Robin
    Cahill, Anne Marie
    Stern, Whitney
    Pachikara, Reshma
    Gallagher, Paul R.
    Watcha, Mehernoor
    Pediatric Critical Care Medicine, 2009, 10 (01) : 45 - 48
  • [46] Ultrasound-guided central venous cannulation in infants and children
    Åsheim, P
    Mostad, U
    Aadahl, P
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2002, 46 (04) : 390 - 392
  • [47] Ultrasound-guided cannulation of the brachiocephalic vein in neonates and infants
    Oulego-Erroz, Ignacio
    Alonso-Quintela, Paula
    Dominguez, Patricia
    Rodriguez-Blanco, Silvia
    Muniz-Fontan, Manoel
    Munoz-Lozon, Ana
    Lopez-Blanco, Gloria
    Rodriguez-Nunez, Antonio
    ANALES DE PEDIATRIA, 2016, 84 (06): : 331 - 336
  • [48] Implementation of ultrasound-guided cannulation training for foundation doctors
    Pham, Mia
    Aldous, Robert
    Brincat, Stephan
    CLINICAL MEDICINE, 2024, 24 (06)
  • [49] Ultrasound-Guided Central Venous Cannulation in Bariatric Patients
    Brusasco, Claudia
    Corradi, Francesco
    Zattoni, Pier Luigi
    Launo, Claudio
    Leykin, Yigal
    Palermo, Salvatore
    OBESITY SURGERY, 2009, 19 (10) : 1365 - 1370
  • [50] A novel technique for ultrasound-guided supraclavicular subclavian cannulation
    Mallin, Michael
    Louis, Hunter
    Madsen, Troy
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2010, 28 (08): : 966 - 969