Development and Usability of an Inexpensive and Reusable Phantom for Ultrasound-Guided Needle Cannulation

被引:0
|
作者
Linnet, Jacob [1 ,2 ]
Obinah, Magnus P. [3 ]
Madsen, Mikkel H. [4 ]
Moller, Magnus M. [1 ]
Russell, Lene [5 ]
Ekelund, Kim [1 ,6 ]
Svendsen, Morten B. [1 ,7 ]
Thinggaard, Ebbe [1 ,8 ]
机构
[1] Copenhagen Acad Med Educ & Simulat, Med Educ & Simulat, Copenhagen, Denmark
[2] Univ Copenhagen, Hlth & Med Sci, Copenhagen, Denmark
[3] Copenhagen Univ Hosp, Herlev & Gentofte Hosp, Plast Surg, Copenhagen, Denmark
[4] Copenhagen Univ Hosp, Amager & Hvidovre Hosp, Anesthesiol & Intens Care, Copenhagen, Denmark
[5] Copenhagen Univ Hosp, Herlev & Gentofte Hosp, Anesthesiol & Intens Care, Copenhagen, Denmark
[6] Copenhagen Univ Hosp, Rigshosp Hosp, Anesthesiol & Intens Care, Copenhagen, Denmark
[7] Univ Copenhagen, Comp Sci, Copenhagen, Denmark
[8] Univ Copenhagen, Clin Med, Copenhagen, Denmark
关键词
emergency medicine; anesthesiology; simulation trainer; ultrasound phantom; peripheral vein catheter; ultrasound guided; PROCEDURAL SKILLS; ACCESS;
D O I
10.7759/cureus.52583
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Ultrasound -guided peripheral venous catheter placement (UG-PVCP) is a key skill for establishing intravenous access, especially in patients with anatomical challenges. Ultrasound is highly operatordependent, and it is essential to ensure a sufficient level of competence when educating healthcare professionals. Competence can be acquired through simulation -based training (SBT) using phantoms or simulators. We developed a phantom for SBT, and in this study, we explore the phantom's usability and technical fidelity. Methods Novices with no experience in UG-PVCP and experts who routinely performed the procedure were asked to perform three ultrasound -guided catheter placement attempts on the phantom. Afterward, they were asked to complete a usability questionnaire consisting of 14 questions exploring the usability and fidelity of the phantom. Results Fifty-seven participants were included in the study: 29 novices and 28 experts. When assessing positive questions about the frequency of use, ease of use, integration of functionality, quickness to learn, and confidence level, the study showed a median score of 4 to 5 out of 5 in the two groups. The median was 1 to 2 out of 5 for negative questions assessing cumbersomeness, unnecessary complexity, and model inconsistency. In an additional comment textbox, one participant mentioned that the cannulation did not feel realistic but that it was good for cannulation practice. Conclusions We believe the phantom is suitable for an educational curriculum since it shows a high level of usability, scoring high on positive questions while scoring low on negative questions, and having high functional fidelity.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Ultrasound-guided brachial and basilic vein cannulation
    Ault, MJ
    ANNALS OF EMERGENCY MEDICINE, 2000, 36 (04) : 399 - 399
  • [32] Reusable 3D printed model for prenatal ultrasound-guided needle procedures
    Pape, Kelsey J.
    Wilson, Ashtin
    Cronin, Nichole
    Ellis, Nick
    Parmenter, Jacob
    Rouse, Caroline E.
    Shanks, Anthony L.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2023, 228 (01) : S344 - S345
  • [33] Ultrasound-Guided Cannulation of the Hemodialysis Arteriovenous Access
    Ward, Frank
    Faratro, Rose
    McQuillan, Rory F.
    SEMINARS IN DIALYSIS, 2017, 30 (04) : 319 - 325
  • [34] Ultrasound-Guided Cannulation of the Subclavian Vein - An Update
    Wenk, Manuel
    Engel, Philipp
    Ermert, Thomas
    NEW ENGLAND JOURNAL OF MEDICINE, 2018, 379 (16):
  • [35] Ultrasound-Guided Internal Jugular Vein Cannulation
    Maslove, David
    Mihm, Frederick
    NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (08): : 796 - 796
  • [36] Development of a Targeting Task Trainer for Ultrasound-Guided Needle Procedures
    Nitsche, Joshua F.
    Russell, Bronwyn C.
    Trinidad, Mari Charisse B.
    Brost, Brian C.
    OBSTETRICS AND GYNECOLOGY, 2014, 123 : 19S - 19S
  • [37] Using an abdominal phantom to teach urology residents ultrasound-guided percutaneous needle placement
    Filippou, Pauline
    Odisho, Anobel
    Ramaswamy, Krishna
    Usawachintachit, Manint
    Hu, Weiguo
    Li, Jianxing
    Chi, Thomas
    INTERNATIONAL BRAZ J UROL, 2016, 42 (04): : 717 - 726
  • [39] Individualized Ultrasound-Guided Intervention Phantom Development, Fabrication, and Proof of Concept
    Pierce, Theodore T.
    Ottensmeyer, Mark P.
    Som, Avik
    Brattain, Laura J.
    Werblin, Joshua S.
    Sutphin, Patrick D.
    Schoen, Scott
    Johnson, Matthew R.
    Gjesteby, Lars
    Telfer, Brian A.
    Samir, Anthony E.
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [40] The Ultrasound-Guided Block Needle Holster
    Chiong, Katya H.
    Graber, Raymond
    REGIONAL ANESTHESIA AND PAIN MEDICINE, 2009, 34 (04) : 381 - 382