Development and Usability of an Inexpensive and Reusable Phantom for Ultrasound-Guided Needle Cannulation

被引:0
|
作者
Linnet, Jacob [1 ,2 ]
Obinah, Magnus P. [3 ]
Madsen, Mikkel H. [4 ]
Moller, Magnus M. [1 ]
Russell, Lene [5 ]
Ekelund, Kim [1 ,6 ]
Svendsen, Morten B. [1 ,7 ]
Thinggaard, Ebbe [1 ,8 ]
机构
[1] Copenhagen Acad Med Educ & Simulat, Med Educ & Simulat, Copenhagen, Denmark
[2] Univ Copenhagen, Hlth & Med Sci, Copenhagen, Denmark
[3] Copenhagen Univ Hosp, Herlev & Gentofte Hosp, Plast Surg, Copenhagen, Denmark
[4] Copenhagen Univ Hosp, Amager & Hvidovre Hosp, Anesthesiol & Intens Care, Copenhagen, Denmark
[5] Copenhagen Univ Hosp, Herlev & Gentofte Hosp, Anesthesiol & Intens Care, Copenhagen, Denmark
[6] Copenhagen Univ Hosp, Rigshosp Hosp, Anesthesiol & Intens Care, Copenhagen, Denmark
[7] Univ Copenhagen, Comp Sci, Copenhagen, Denmark
[8] Univ Copenhagen, Clin Med, Copenhagen, Denmark
关键词
emergency medicine; anesthesiology; simulation trainer; ultrasound phantom; peripheral vein catheter; ultrasound guided; PROCEDURAL SKILLS; ACCESS;
D O I
10.7759/cureus.52583
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Ultrasound -guided peripheral venous catheter placement (UG-PVCP) is a key skill for establishing intravenous access, especially in patients with anatomical challenges. Ultrasound is highly operatordependent, and it is essential to ensure a sufficient level of competence when educating healthcare professionals. Competence can be acquired through simulation -based training (SBT) using phantoms or simulators. We developed a phantom for SBT, and in this study, we explore the phantom's usability and technical fidelity. Methods Novices with no experience in UG-PVCP and experts who routinely performed the procedure were asked to perform three ultrasound -guided catheter placement attempts on the phantom. Afterward, they were asked to complete a usability questionnaire consisting of 14 questions exploring the usability and fidelity of the phantom. Results Fifty-seven participants were included in the study: 29 novices and 28 experts. When assessing positive questions about the frequency of use, ease of use, integration of functionality, quickness to learn, and confidence level, the study showed a median score of 4 to 5 out of 5 in the two groups. The median was 1 to 2 out of 5 for negative questions assessing cumbersomeness, unnecessary complexity, and model inconsistency. In an additional comment textbox, one participant mentioned that the cannulation did not feel realistic but that it was good for cannulation practice. Conclusions We believe the phantom is suitable for an educational curriculum since it shows a high level of usability, scoring high on positive questions while scoring low on negative questions, and having high functional fidelity.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Evaluation of a novel needle guide for ultrasound-guided phantom vessel cannulation
    Luyet, C.
    Hartwich, V.
    Urwyler, N.
    Schumacher, P. M.
    Eichenberger, U.
    Vogt, A.
    ANAESTHESIA, 2011, 66 (08) : 715 - 720
  • [2] A low-cost reusable phantom for ultrasound-guided subclavian vein cannulation
    Cheruparambath, Varun
    Sampath, Sriram
    Deshikar, Lakshmikanthan N.
    Ismail, Haji Mohammed
    Bhuvana, Krishna
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2012, 16 (03) : 163 - 165
  • [3] A REALISTIC PHANTOM FOR ULTRASOUND-GUIDED CENTRAL VENOUS CANNULATION
    Ng, Si Yen
    Lin, Chi-Lun
    PROCEEDINGS OF THE 2020 DESIGN OF MEDICAL DEVICES CONFERENCE (DMD2020), 2020,
  • [4] Inexpensive homemade models for ultrasound-guided vein cannulation training
    Di Domenico, Stefano
    Santori, Gregorio
    Porcile, Elisa
    Licausi, Martina
    Centanaro, Monica
    Valente, Umberto
    JOURNAL OF CLINICAL ANESTHESIA, 2007, 19 (07) : 491 - 496
  • [5] A training phantom for ultrasound-guided needle insertion and suturing
    Nattagh, Khashayar
    Siauw, Timmy
    Pouliot, Jean
    Hsu, I-Chow
    Cunha, J. Adam
    BRACHYTHERAPY, 2014, 13 (04) : 413 - 419
  • [6] A Novel Phantom for Teaching and Learning Ultrasound-guided Needle Manipulation
    Sultan, Syed Farjad
    Iohom, Gabriella
    Shorten, George
    JOURNAL OF MEDICAL ULTRASOUND, 2013, 21 (03) : 152 - 155
  • [7] Ultrasound-guided arterial cannulation
    Ashworth, Alan
    Arrowsmith, Joseph E.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (03) : 307 - 307
  • [8] Needle and guidewire visualization in ultrasound-guided internal jugular vein cannulation
    Moak, James H.
    Lyons, Michael S.
    Wright, Stewart W.
    Lindsell, Christopher J.
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2011, 29 (04): : 432 - 436
  • [9] AN INEXPENSIVE, EASILY CONSTRUCTED, REUSABLE TASK TRAINER FOR SIMULATING ULTRASOUND-GUIDED PERICARDIOCENTESIS
    Zerth, Herb
    Harwood, Robert
    Tommaso, Laura
    Girzadas, Daniel V., Jr.
    JOURNAL OF EMERGENCY MEDICINE, 2012, 43 (06): : 1066 - 1069
  • [10] ULTRASOUND-GUIDED FINE-NEEDLE ASPIRATION - AN INEXPENSIVE MODIFICATION OF THE TECHNIQUE
    PAPAGEORGES, M
    GAVIN, PR
    SANDE, RD
    BARBEE, DD
    VETERINARY RADIOLOGY, 1988, 29 (06): : 269 - 271