Clinical prospective intra-individual comparison after mix-and-match implantation of a monofocal EDOF and a diffractive trifocal IOL

被引:8
作者
Danzinger, Victor [1 ]
Schartmueller, Daniel [1 ]
Schwarzenbacher, Luca [1 ]
Roggla, Veronika [1 ]
Abela-Formanek, Claudette [1 ]
Menapace, Rupert [1 ]
Leydolt, Christina [1 ]
机构
[1] Med Univ Vienna, Dept Ophthalmol & Optometry, Vienna, Austria
关键词
EXTENDED DEPTH; INTRAOCULAR LENSES; VISUAL OUTCOMES; BILATERAL IMPLANTATION; CONTRAST SENSITIVITY; OPTICAL-QUALITY; FOCUS; VISION; RANGE; DISSATISFACTION;
D O I
10.1038/s41433-023-02682-x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
ObjectivesTo assess intra-individually visual acuity (VA) and subjective outcome after mix-and-match implantation of a monofocal EDOF IOL and a diffractive trifocal IOL.MethodsThe monofocal EDOF Isopure IOL was implanted in the dominant eye and the trifocal FineVision HP IOL in the non-dominant eye. Postoperative evaluation included VA at various distances, contrast acuity, monocular defocus curves, decentration and tilt, wavefront aberrometry, VF-7 questionnaire and a halo and glare simulator.Results50 eyes of 25 subjects were enroled. The trifocal IOL performed better at monocular DCNVA (p < 0.01) and at defocus levels of -1.5D to -4.0D (p < 0.01), the monofocal EDOF IOL was better at -0.5D (p = 0.013). No differences in monocular BCDVA, DCIVA, contrast acuity, decentration or tilt were observed (p > 0.05). Wavefront analysis revealed lower HOAs in the trifocal group at 5 mm (p < 0.01) and no difference (p = 0.107) at 3 mm pupil aperture. The monofocal EDOF IOL displayed increased negative SA at 5 mm (p < 0.01) and 3 mm (p < 0.01) pupil diameter. Low values of optical phenomena and satisfying results of the VF-7 questionnaire were obtained.ConclusionExcellent visual performance and low rates of optical phenomena were achieved after mix-and-match implantation of the monofocal EDOF Isopure IOL and the trifocal FineVision HP IOL. Trifocal IOL implantation in the non-dominant eye may decrease optical disturbing phenomena. Similar results were observed for monocular distance, intermediate and contrast VA. The trifocal IOL provided better monocular near VA. Decentration and tilt and HOAs were low.
引用
收藏
页码:321 / 327
页数:7
相关论文
共 32 条
[1]   Extended depth of focus intraocular lenses for presbyopia [J].
Akella, Sruti S. ;
Juthani, Viral V. .
CURRENT OPINION IN OPHTHALMOLOGY, 2018, 29 (04) :319-323
[2]  
Ashena Zahra, 2020, Vision (Basel), V4, DOI 10.3390/vision4030041
[3]   Visual Outcomes Following Bilateral Implantation of Two Diffractive Trifocal Intraocular Lenses in 10 084 Eyes [J].
Bilbao-Calabuig, Rafael ;
Llovet-Rausell, Andrea ;
Ortega-Usobiaga, Julio ;
Martinez-del-Pozo, Mercedes ;
Mayordomo-Cerda, Fernando ;
Segura-Albentosa, Celia ;
Baviera, Julio ;
Llovet-Osuna, Fernando .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2017, 179 :55-66
[4]   Clinical and Aberrometric Evaluation of a New Monofocal IOL with Intermediate Vision Improvement [J].
Bova, Alessandro ;
Vita, Stefano .
JOURNAL OF OPHTHALMOLOGY, 2022, 2022
[5]   Association of ocular dominance and anisometropic myopia [J].
Cheng, CY ;
Yen, MY ;
Lin, HY ;
Hsia, WW ;
Hsu, WM .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (08) :2856-2860
[6]   Clinical outcomes of a new extended range of vision intraocular lens: International Multicenter Concerto Study [J].
Cochener, Beatrice .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (09) :1268-1275
[7]   Multifocal versus monofocal intraocular lenses after cataract extraction [J].
de Silva, Samantha R. ;
Evans, Jennifer R. ;
Kirthi, Varo ;
Ziaei, Mohammed ;
Leyland, Martin .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2016, (12)
[8]   Dissatisfaction after implantation of multifocal intraocular lenses [J].
de Vries, Niels E. ;
Webers, Carroll A. B. ;
Touwslager, Wouter R. H. ;
Bauer, Noel J. C. ;
de Brabander, John ;
Berendschot, Tos T. ;
Nuijts, Rudy M. M. A. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (05) :859-865
[9]   Through-Focus Vision Performance and Light Disturbances of 3 New Intraocular Lenses for Presbyopia Correction [J].
Escandon-Garcia, Santiago ;
Ribeiro, Filomena J. ;
McAlinden, Colm ;
Queiros, Antonio ;
Gonzalez-Meijome, Jose M. .
JOURNAL OF OPHTHALMOLOGY, 2018, 2018
[10]   Evaluation of actual retinal images produced by misaligned aspheric intraocular lenses in a model eye [J].
Fujikado, Takashi ;
Saika, Makoto .
CLINICAL OPHTHALMOLOGY, 2014, 8 :2415-2423