CT perfusion extended window ischemic core estimation: Bayesian algorithm versus oscillation index singular value decomposition

被引:0
作者
Morelli, Nicola [1 ,2 ,5 ,6 ]
Immovilli, Paolo [1 ]
Giacopazzi, Elena [3 ]
Rota, Eugenia [4 ]
Spallazzi, Marco [3 ]
Zaino, Domenica [1 ]
Colombi, Davide [2 ]
Guidetti, Donata [1 ]
Michieletti, Emanuele [2 ]
机构
[1] Guglielmo da Saliceto Hosp, Neurol Unit, Piacenza, Italy
[2] Guglielmo da Saliceto Hosp, Radiol Unit, Piacenza, Italy
[3] Hosp Parma, Neurol Unit, Parma, Italy
[4] San Giacomo Hosp Novi Ligure, Neurol Unit, Alessandria, Italy
[5] Guglielmo da Saliceto Hosp, Neurol Unit, Via Taverna 49, I-29121 Piacenza, Italy
[6] Guglielmoda Saliceto Hosp, Radiol Unit, Via Taverna 49, I-29121 Piacenza, Italy
关键词
Bayesian algorithm; CT perfusion; extended window; ischemic core; singular value decomposition; stroke; STROKE; ACCURACY; INFARCT; TIME;
D O I
10.1111/jon.13090
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and PurposeIschemic core estimation by CT perfusion (CTp) is a diagnostic challenge, mainly because of the intrinsic noise associated with perfusion data. However, an accurate and reliable quantification of the ischemic core is critical in the selection of patients for reperfusion therapies. Our study aimed at assessing the diagnostic accuracy of two different CTp postprocessing algorithms, that is, the Bayesian Method and the oscillation index singular value decomposition (oSVD). MethodsAll the consecutive stroke patients studied in the extended time window (>4.5 hours from stroke onset) by CTp and diffusion-weighted imaging (DWI), between October 2019 and December 2021, were enrolled. The agreement between both algorithms and DWI was assessed by the Bland-Altman plot, Wilcoxon signed-rank test, Spearman's rank correlation coefficient, and the intraclass correlation coefficient (ICC). ResultsTwenty-four patients were enrolled (average age: 72 +/- 15 years). The average National Institutes of Health Stroke Scale was 14.42 +/- 6.75, the median Alberta Stroke Program Early CT score was 8.50 (interquartile range [IQR] = 7.75-9), and median time from stroke onset to neuroimaging was 7.5 hours (IQR = 6.5-8). There was an excellent correlation between DWI and oSVD (rho = .87, p-value < .001) and DWI and Bayesian algorithm (rho = .94, p-value < .001). There was a stronger ICC between DWI and Bayesian algorithm (.97, 95% confidence interval [CI]: .92-.99, p-value < .001) than between DWI and oSVD (.59, 95% CI: .26-.8, p-value < .001). DiscussionThe agreement between Bayesian algorithm and DWI was greater than between oSVD and DWI in the extended window. The more accurate estimation of the ischemic core offered by the Bayesian algorithm may well play a critical role in the accurate selection of patients for reperfusion therapies.
引用
收藏
页码:381 / 386
页数:6
相关论文
共 22 条
[1]   Time-Dependent Computed Tomographic Perfusion Thresholds for Patients With Acute Ischemic Stroke [J].
d'Esterre, Christopher D. ;
Boesen, Mari E. ;
Ahn, Seong Hwan ;
Pordeli, Pooneh ;
Najm, Mohamed ;
Minhas, Priyanka ;
Davari, Paniz ;
Fainardi, Enrico ;
Rubiera, Marta ;
Khaw, Alexander V. ;
Zini, Andrea ;
Frayne, Richard ;
Hill, Michael D. ;
Demchuk, Andrew M. ;
Sajobi, Tolulope T. ;
Forkert, Nils D. ;
Goyal, Mayank ;
Lee, Ting Y. ;
Menon, Bijoy K. .
STROKE, 2015, 46 (12) :3390-3397
[2]  
Davis A., 2020, PRESENTED 58 AM SOC
[3]   Controversies in Imaging of Patients With Acute Ischemic Stroke: AJR Expert Panel Narrative Review [J].
de Oliveira, Eduardo Portela ;
Fiebach, Jochen B. ;
Vagal, Achala ;
Schaefer, Pamela W. ;
Aviv, Richard, I .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2021, 217 (05) :1027-1037
[4]   On the design of filters for fourier and oSVD-based deconvolution in bolus tracking perfusion MRI [J].
Gall, Peter ;
Emerich, Philipp ;
Kjolby, Birgitte F. ;
Kellner, Elias ;
Mader, Irina ;
Kiselev, Valerij G. .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2010, 23 (03) :187-195
[5]   Low signal, high noise and large uncertainty make CT perfusion unsuitable for acute ischemic stroke patient selection for endovascular therapy [J].
Gonzalez, R. Gilberto .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2012, 4 (04) :242-245
[6]   Challenging the Ischemic Core Concept in Acute Ischemic Stroke Imaging [J].
Goyal, Mayank ;
Ospel, Johanna M. ;
Menon, Bijoy ;
Almekhlafi, Mohammed ;
Jayaraman, Mahesh ;
Fiehler, Jens ;
Psychogios, Marios ;
Chapot, Rene ;
van der Lugt, Aad ;
Liu, Jianmin ;
Yang, Pengfei ;
Agid, Ronit ;
Hacke, Werner ;
Walker, Melanie ;
Fischer, Urs ;
Asdaghi, Negar ;
McTaggart, Ryan ;
Srivastava, Padma ;
Nogueira, Raul G. ;
Moret, Jacques ;
Saver, Jeffrey L. ;
Hill, Michael D. ;
Dippel, Diederik ;
Fisher, Marc .
STROKE, 2020, 51 (10) :3147-3155
[7]   Comparison of a Bayesian estimation algorithm and singular value decomposition algorithms for 80-detector row CT perfusion in patients with acute ischemic stroke [J].
Ichikawa, Shota ;
Yamamoto, Hiroyuki ;
Morita, Takumi .
RADIOLOGIA MEDICA, 2021, 126 (06) :795-803
[8]   Bayesian Analysis of Perfusion-weighted Imaging to Predict Infarct Volume: Comparison with Singular Value Decomposition [J].
Kudo, Kohsuke ;
Boutelier, Timothe ;
Pautot, Fabrice ;
Honjo, Kaneyoshi ;
Hu, Jin-Qing ;
Wang, Hai-Bin ;
Shintaku, Katsuya ;
Uwano, Ikuko ;
Saski, Makoto .
MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2014, 13 (01) :45-50
[9]   Accuracy and Reliability Assessment of CT and MR Perfusion Analysis Software Using a Digital Phantom [J].
Kudo, Kohsuke ;
Christensen, Soren ;
Sasaki, Makoto ;
Ostergaard, Leif ;
Shirato, Hiroki ;
Ogasawara, Kuniaki ;
Wintermark, Max ;
Warach, Steven .
RADIOLOGY, 2013, 267 (01) :201-211
[10]   Differences in CT Perfusion Maps Generated by Different Commercial Software: Quantitative Analysis by Using Identical Source Data of Acute Stroke Patients [J].
Kudo, Kohsuke ;
Sasaki, Makoto ;
Yamada, Kei ;
Momoshima, Suketaka ;
Utsunomiya, Hidetsuna ;
Shirato, Hiroki ;
Ogasawara, Kuniaki .
RADIOLOGY, 2010, 254 (01) :200-209