Computational Analysis of Tube Wall Temperature of Superheater in 1000 MW Ultra-Supercritical Boiler Based on the Inlet Thermal Deviation

被引:7
作者
Li, Pei [1 ]
Bao, Ting [2 ]
Guan, Jian [3 ]
Shi, Zifu [4 ]
Xie, Zengxiao [5 ]
Zhou, Yonggang [4 ]
Zhong, Wei [1 ]
机构
[1] Zhejiang Univ, Inst Thermal Sci & Power Syst, Hangzhou 310027, Peoples R China
[2] Zhejiang Zheneng Technol Res Inst Co Ltd, Zhejiang Prov Key Lab Energy Conservat & Pollutant, Hangzhou 311121, Peoples R China
[3] Zhejiang Prov Energy Grp Co Ltd, Hangzhou 310007, Peoples R China
[4] Zhejiang Univ, Inst Thermal Power Engn, State Key Lab Clean Energy Utilizat, Hangzhou 310027, Peoples R China
[5] Zhejiang Zheneng Zhongmei Zhoushan Coal & Elect Co, Zhoushan 316131, Peoples R China
关键词
ultra-supercritical boiler; final superheater; numerical simulation; tube wall temperature calculation; thermal deviation condition; NUMERICAL-SIMULATION; STEAM; REHEATER; MODEL; SIDE; FLOW;
D O I
10.3390/en16031539
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Local over-temperature is one of the main reasons for boiler tube failures (BTF). By accurately monitoring and controlling tube wall temperature, local over-temperature can be avoided. Based on the measured flue gas parameters and numerical simulation, a method of thermal deviation calculation is proposed in this study for the on-line calculation of the tube wall temperature of boiler superheaters. The full-size three-dimensional numerical simulation was presented on the combustion in a pulverized coal-fired boiler of 1000 MW ultra-supercritical (USC) unit. A difference in the thermal deviation of the vertical direction was innovatively introduced into a segmented discrete model, and the thermal deviation condition conforming to reality was introduced into the calculation. An on-line calculation system developed based on the current calculation method was applied in a 1000 MW USC unit. The calculated local high-temperature zone was consistent with the actual over-temperature position and conformed to the law of the allowable metal temperature of the final superheater (FSH) serpentines segment. The comparison results showed that the calculated data by this method were more reflective of tube wall temperature change with boiler loads than the measured data. According to the calculated local over-temperature zone, the immediate warning response can effectively reduce the possibility of over-temperature BTF.
引用
收藏
页数:15
相关论文
共 29 条
[1]   Numerical and experimental study on biased tube temperature problem in tangential firing boiler [J].
Akkinepally, Bhargav ;
Shim, Jaesool ;
Yoo, Kisoo .
APPLIED THERMAL ENGINEERING, 2017, 126 :92-99
[2]  
[Anonymous], CHINA ELECT COUNCIL
[3]  
BP, 2022, Statistical Review of World Energy
[4]  
Dooley B, 1997, POWER ENG, V101, P56
[5]  
French D.N., 1993, METALLURGICAL FAILUR
[6]   Modelling and simulation of fluid flow and heat transfer in the convective zone of a power-generation boiler [J].
Gomez, Antonio ;
Fueyo, Norberto ;
Diez, Luis Ignacio .
APPLIED THERMAL ENGINEERING, 2008, 28 (5-6) :532-546
[7]   On the failure of steam-side oxide scales in high temperature components of boilers during unsteady thermal processes [J].
Huang, Jun-Lin ;
Zhou, Ke-Yi ;
Xu, Jian-Qun ;
Bian, Cai-Xia .
JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2013, 26 (01) :22-31
[8]   RESEARCH ON THE PREPARATION AND PROCESS CONDITIONS OF C4 OLEFINS USING GREY PREDICTION MODEL AND MULTIPLE LINEAR REGRESSION MODEL [J].
Jin, Ding-Ge ;
Wang, Xiao-Feng ;
Xu, Li-Xiang ;
Hu, Ren-Zhi ;
Zhang, Chen ;
Zhang, Sheng-Feng ;
Tang, Yuan-Yan .
PROCEEDINGS OF 2022 INTERNATIONAL CONFERENCEON WAVELET ANALYSIS AND PATTERN RECOGNITION (ICWAPR), 2022, :1-6
[9]  
Kuznetsov N.W., 1973, Thermal calculations of steam boilers. standard method, Energ
[10]   Numerical investigation on the impact of variable particle radiation properties on the heat transfer in high ash pulverized coal boiler through co-simulation [J].
Laubscher, Ryno ;
Rousseau, Pieter .
ENERGY, 2020, 195