共 81 条
Determination of tin in geological materials using LA-ICP-MS: Seemingly simple analysis?
被引:1
作者:
Hlozkova, Michaela
[1
]
Galiova, Michaela Vasinova
[2
,3
]
Coufalik, Pavel
[4
]
Breiter, Karel
[1
,3
,5
]
Skoda, Radek
[6
]
Brezina, Matej
[7
]
Brtnicky, Martin
[2
,3
,8
]
Kynicky, Jindrich
[3
]
机构:
[1] Masaryk Univ, Fac Sci, Dept Chem, Kotlarska 2, Brno 61137, Czech Republic
[2] Brno Univ Technol, Inst Chem & Technol Environm Protect, Fac Chem, Purkynova 118, Brno 61200, Czech Republic
[3] BIC Brno, Purkynova 125, Brno 61200, Czech Republic
[4] Czech Acad Sci v v i, Inst Analyt Chem, Veveri 97, Brno 60200, Czech Republic
[5] Czech Acad Sci, Inst Geol, Rozvojova 269, Prague 6, Czech Republic
[6] Masaryk Univ, Fac Sci, Dept Geol Sci, Kotlarska 2, Brno 61137, Czech Republic
[7] Brno Univ Technol, Inst Mat Sci, Fac Chem, Purkynova 118, Brno 61200, Czech Republic
[8] Mendel Univ Brno, Fac Agrisci, Dept Agrochem Soil Sci Microbiol & Plant Nutr, Zemedelska 1, Brno 61300, Czech Republic
来源:
关键词:
Tin;
Memory effect;
Spectral and non-spectral interferences;
Homogeneity of standards;
LA-ICP-MS;
INDUCTIVELY-COUPLED PLASMA;
TRACE-ELEMENT ANALYSIS;
PARTICLE-SIZE DISTRIBUTION;
GLASS REFERENCE MATERIALS;
NIST SRM GLASSES;
NM ND-YAG;
LASER-ABLATION;
MASS-SPECTROMETRY;
HIGH-RESOLUTION;
ACCURATE DETERMINATION;
D O I:
10.1016/j.chemgeo.2023.121775
中图分类号:
P3 [地球物理学];
P59 [地球化学];
学科分类号:
0708 ;
070902 ;
摘要:
Laser ablation inductively coupled plasma mass spectrometry is a unique technique designated for in situ analysis of a wide variety of solid samples. Nowadays, LA-ICP-MS is almost routinely used to study chemical and isotopic composition of geological materials. This paper reviews our experience with the analysis of tin in geological samples and comprehensively summarizes the limitations that may lead to inaccurate and imprecise outcomes. Experimental results show the extent of cross-contamination given by the ablation of materials containing tenths and tens of %m/m of Sn, and elucidate the impact of contamination on a background progress. Moreover, an analysis is also jeopardized by the occurrence of doubly charged ions of uranium as well as by the matrix effect amplified with operating conditions. Finally, the inhomogeneity of NIST SRM 614 is highlighted via 2D mapping especially within the rim area where tin content reaches up to 8 mg kg- 1. Furthermore, a real quartz sample is subjected to LA-ICP-MS analysis to demonstrate the manifestation of discussed negative effects. The true tin content in quartz sample and NIST 614 is verified via GF-AAS. The result of NIST 614 bulk analysis is in a good agreement with GeoReM value.
引用
收藏
页数:15
相关论文