Sizing of Hybrid Power Systems for Off-Grid Applications Using Airborne Wind Energy

被引:4
作者
Reuchlin, Sweder [1 ]
Joshi, Rishikesh [1 ]
Schmehl, Roland [1 ]
机构
[1] Delft Univ Technol, Fac Aerosp Engn, NL-2629 HS Delft, Netherlands
基金
荷兰研究理事会;
关键词
hybrid power systems; airborne wind energy; modelling and sizing; off-grid; levelised cost of electricity; system integration;
D O I
10.3390/en16104036
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The majority of remote locations not connected to the main electricity grid rely on diesel generators to provide electrical power. High fuel transportation costs and significant carbon emissions have motivated the development and installation of hybrid power systems using renewable energy such these locations. Because wind and solar energy is intermittent, such sources are usually combined with energy storage for a more stable power supply. This paper presents a modelling and sizing framework for off-grid hybrid power systems using airborne wind energy, solar PV, batteries and diesel generators. The framework is based on hourly time-series data of wind resources from the ERA5 reanalysis dataset and solar resources from the National Solar Radiation Database maintained by NREL. The load data also include hourly time series generated using a combination of modelled and real-life data from the ENTSO-E platform maintained by the European Network of Transmission System Operators for Electricity. The backbone of the framework is a strategy for the sizing of hybrid power system components, which aims to minimise the levelised cost of electricity. A soft-wing ground-generation-based AWE system was modelled based on the specifications provided by Kitepower B.V. The power curve was computed by optimising the operation of the system using a quasi-steady model. The solar PV modules, battery systems and diesel generator models were based on the specifications from publicly available off-the-shelf solutions. The source code of the framework in the MATLAB environment was made available through a GitHub repository. For the representation of results, a hypothetical case study of an off-grid military training camp located in Marseille, France, was described. The results show that significant reductions in the cost of electricity were possible by shifting from purely diesel-based electricity generation to an hybrid power system comprising airborne wind energy, solar PV, batteries and diesel.
引用
收藏
页数:15
相关论文
共 44 条
  • [1] [Anonymous], 2012, Renewable Power Generation Costs
  • [2] Airborne wind energy resource analysis
    Bechtle, Philip
    Schelbergen, Mark
    Schmehl, Roland
    Zillmann, Udo
    Watson, Simon
    [J]. RENEWABLE ENERGY, 2019, 141 : 1103 - 1116
  • [3] The climatological relationships between wind and solar energy supply in Britain
    Bett, Philip E.
    Thornton, Hazel E.
    [J]. RENEWABLE ENERGY, 2016, 87 : 96 - 110
  • [4] Cole W, 2021, COST PROJECTIONS UTI
  • [5] Optimal battery operation for revenue maximization of wind-storage hybrid power plant
    Das, Kaushik
    Grapperon, Anatole Louis Theodore Philippe
    Sorensen, Poul E.
    Hansen, Anca D.
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2020, 189
  • [6] De la Garza Cuevas R., 2018, THESIS DELFT U TECHN
  • [7] Dykes K, 2020, Opportunities for research and development of hybrid power plants
  • [8] Enerkite GmbH, EK200 AIRB WIND EN S
  • [9] Enerwhere, WHAT WILL IT TAK AIR
  • [10] entsoe, ENTSOE E TOTAL LOAD