Influence and optimization strategy of the magnetic field in 1.5 T MR-linac liver stereotactic radiotherapy

被引:3
作者
Liu, Xin [1 ,2 ]
Yin, Peijun [2 ]
Li, Tengxiang [3 ]
Yin, Yong [1 ,2 ]
Li, Zhenjiang [2 ]
机构
[1] Southwest Med Univ, Dept Oncol, Affiliated Hosp, Luzhou 646000, Peoples R China
[2] Shandong First Med Univ & Shandong Acad Med Sci, Shandong Canc Hosp & Inst, Dept Radiat Phys, Jinan 250117, Peoples R China
[3] Univ South China, Sch Nucl Sci & Technol, Hengyang 421001, Peoples R China
关键词
Liver cancer; Radiotherapy; MR-LINAC; Magnetic field; Field; IMRT; ACCELERATOR; IMPACT; SCANNER; CANCER;
D O I
10.1186/s13014-023-02356-8
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
ObjectiveTo compare intensity reduction plans for liver cancer with or without a magnetic field and optimize field and subfield numbers in the intensity-modulated radiotherapy (IMRT) plans designed for liver masses in different regions.MethodsThis retrospective study included 62 patients who received radiotherapy for liver cancer at Shandong Cancer Hospital. Based on each patient's original individualized intensity-modulated plan (plan1.5 T), a magnetic field-free plan (plan0 T) and static intensity-modulated plan with four different optimization schemes were redesigned for each patient. The differences in dosimetric parameters among plans were compared.ResultsIn the absence of a magnetic field in the first quadrant, PTV Dmin increased (97.75 +/- 17.55 vs. 100.96 +/- 22.78)%, Dmax decreased (121.48 +/- 29.68 vs. 119.06 +/- 28.52)%, D98 increased (101.35 +/- 7.42 vs. 109.35 +/- 26.52)% and HI decreased (1.14 +/- 0.14 vs. 1.05 +/- 0.01). In the absence of a magnetic field in the second quadrant, PTV Dmin increased (84.33 +/- 19.74 vs. 89.96 +/- 21.23)%, Dmax decreased (105 +/- 25.08 vs. 104.05 +/- 24.86)%, and HI decreased (1.04 +/- 0.25 vs. 0.99 +/- 0.24). In the absence of a magnetic field in the third quadrant, PTV Dmax decreased (110.21 +/- 2.22 vs. 102.31 +/- 26)%, L-P V30 decreased (10.66 +/- 9.19 vs. 5.81 +/- 3.22)%, HI decreased (1.09 +/- 0.02 vs. 0.98 +/- 0.25), and PTV Dmin decreased (92.12 +/- 4.92 vs. 89.1 +/- 22.35)%. In the absence of a magnetic field in the fourth quadrant, PTV Dmin increased (89.78 +/- 6.72 vs. 93.04 +/- 4.86)%, HI decreased (1.09 +/- 0.01 vs. 1.05 +/- 0.01) and D98 increased (99.82 +/- 0.82 vs. 100.54 +/- 0.84)%. These were all significant differences. In designing plans for tumors in each liver region, a total number of subfields in the first area of 60, total subfields in the second zone of 80, and total subfields in the third and fourth zones of 60 or 80 can achieve the dose effect without a magnetic field.ConclusionIn patients with liver cancer, the effect of a magnetic field on the target dose is more significant than that on doses to organs at risk. By controlling the max total number of subfields in different quadrants, the effect of the magnetic field can be greatly reduced or even eliminated.
引用
收藏
页数:10
相关论文
共 50 条
[21]   Optimization of treatment workflow for 0.35T MR-Linac system [J].
Behzadipour, Mojtaba ;
Palta, Jatinder ;
Ma, Tianjun ;
Yuan, Lulin ;
Kim, Siyong ;
Kirby, Suzanne ;
Torkelson, Laurel ;
Baker, James ;
Koenig, Tammy ;
Khalifa, Mateb Al ;
Hawranko, Robert ;
Richeson, Dylan ;
Fields, Emma ;
Weiss, Elisabeth ;
Song, William Y. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (08)
[22]   Commissioning of a 1.5T Elekta Unity MR-linac: A single institution experience [J].
Snyder, Jeffrey E. ;
St-Aubin, Joel ;
Yaddanapudi, Sridhar ;
Boczkowski, Amanda ;
Dunkerley, David A. P. ;
Graves, Stephen A. ;
Hyer, Daniel E. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (07) :160-172
[23]   Evaluation of Unity 1.5 T MR-linac plan quality in patients with prostate cancer [J].
Tanaka, Shohei ;
Kadoya, Noriyuki ;
Ishizawa, Miyu ;
Katsuta, Yoshiyuki ;
Arai, Kazuhiro ;
Takahashi, Haruna ;
Xiao, Yushan ;
Takahashi, Noriyoshi ;
Sato, Kiyokazu ;
Takeda, Ken ;
Jingu, Keiichi .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (12)
[24]   High-resolution entry and exit surface dosimetry in a 1.5 T MR-linac [J].
Patterson, E. ;
Stokes, P. ;
Cutajar, D. ;
Rosenfeld, A. ;
Baines, J. ;
Metcalfe, P. ;
Powers, M. .
PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2023, 46 (02) :787-800
[25]   Comparison of Intensity Modulated Radiotherapy Treatment Plans Between 1.5T MR-Linac and Conventional Linac [J].
Ding, Shouliang ;
Li, Yongbao ;
Liu, Hongdong ;
Li, Rui ;
Wang, Bin ;
Zhang, Jun ;
Chen, Yan ;
Huang, Xiaoyan .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2021, 20
[26]   A virtual phantom for patient-specific QA On A 1.5T MR-linac [J].
Ji, Mingshuo ;
Li, Zhenjiang ;
Tian, Yuan ;
Zhang, Ke ;
Li, Minghui ;
Chen, Yan .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (05)
[27]   Technical Note: Investigating the impact of field size on patient selection for the 1.5T MR-Linac [J].
Chuter, Robert W. ;
Whitehurst, Philip ;
Choudhury, Ananya ;
van Herk, Marcel ;
McWilliam, Alan .
MEDICAL PHYSICS, 2017, 44 (11) :5667-5671
[28]   Treating locally advanced lung cancer with a 1.5 T MR-Linac - Effects of the magnetic field and irradiation geometry on conventionally fractionated and isotoxic dose-escalated radiotherapy [J].
Bainbridge, Hannah E. ;
Menten, Martin J. ;
Fast, Martin F. ;
Nill, Simeon ;
Oelfke, Uwe ;
McDonald, Fiona .
RADIOTHERAPY AND ONCOLOGY, 2017, 125 (02) :280-285
[29]   Performance of the HYPERSCINT scintillation dosimetry research platform for the 1.5 T MR-linac [J].
Uijtewaal, Prescilla ;
Cote, Benjamin ;
Foppen, Thomas ;
de Vries, Wilfred ;
Woodings, Simon ;
Borman, Pim ;
Lambert-Girard, Simon ;
Therriault-Proulx, Francois ;
Raaymakers, Bas ;
Fast, Martin .
PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (04)
[30]   Dosimetric evaluation of off-axis fields and angular transmission for the 1.5 T MR-linac [J].
van den Dobbelsteen, M. ;
Hackett, S. L. ;
de Vries, J. H. W. ;
van Asselen, B. ;
Oolbekkink, S. ;
Woodings, S. J. ;
Raaymakers, B. W. .
PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (20)