Optical Magnetic Field Microsensors Based on GaN Diode Optopairs Integrated With Magnetic Fluids

被引:3
|
作者
Chen, Jian [1 ,2 ]
Zhu, Ling [3 ]
Tang, Xinke [4 ]
Li, Kwai Hei [1 ,4 ]
机构
[1] Southern Univ Sci & Technol, Sch Microelect, Shenzhen 518055, Peoples R China
[2] Shenzhen Univ, Coll Phys & Optoelect Engn, Shenzhen 518060, Peoples R China
[3] Shenzhen Univ, Coll Phys & Optoelect Engn, Shenzhen 518060, Peoples R China
[4] Peng Cheng Lab, Shenzhen 518055, Peoples R China
基金
中国国家自然科学基金;
关键词
GaN; magnetic field; magnetic fluid; microsensor; optoelectronic integration; FABRY-PEROT SENSOR; REFRACTIVE-INDEX;
D O I
10.1109/JLT.2023.3253672
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this work, the development of optical magnetic microsensors based on chip-scale GaN-on-sapphire diode optopairs integrated with magnetic fluids is demonstrated. The submillimeter-sized optopairs function as light emitters and detectors and the transparent sapphire substrate as light-guiding media is covered with magnetic fluids using PDMS recesses. The magnetic fluid strength introduces the optical reflection introduces changes in optical reflection at the boundary between the sapphire and the magnetic fluid, thus varying the amount of light received by the photodetector. Verified through experimental measurements, the micro-sensor exhibits a wide detection range of 50-2000 Gs and a fast response time of 0.06 s. The developed magnetic sensor provides remarkable features of rapid response, wide measurement range, high compactness, and simplicity of operation, making it well-suited for use in practical applications.
引用
收藏
页码:5153 / 5158
页数:6
相关论文
共 50 条
  • [41] Magnetic Field Tunability of Square Tapered No-Core Fibers Based on Magnetic Fluid
    Miao, Yinping
    Wu, Jixuan
    Lin, Wei
    Song, Binbin
    Zhang, Hao
    Zhang, Kailiang
    Liu, Bo
    Yao, Jianquan
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2014, 32 (23) : 3998 - 4003
  • [42] The effects of external magnetic field upon the stability of ionic magnetic fluids
    Qu, F
    Santos, DR
    Morais, PC
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2004, 272 : 943 - 945
  • [43] Influence of a uniform magnetic field on ultrasonic propagation velocities in magnetic fluids
    Motozawa, Masaaki
    Matsumoto, Yoshiyuki
    Sawada, Tatsuo
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2007, 25 (1-4) : 133 - 138
  • [44] Optical relaxation properties of magnetic fluids under externally magnetic fields
    Bai, Xuekun
    Pu, Shengli
    Wang, Lunwei
    OPTICS COMMUNICATIONS, 2011, 284 (20) : 4929 - 4935
  • [45] Proton nuclear magnetic resonance and optical microscopic studies of magnetic fluids
    Saito, SH
    Ohaba, M
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1999, 68 (04) : 1357 - 1363
  • [46] Effect of magnetic field on properties of MR fluids
    Huang, J
    Zhang, JQ
    Liu, JN
    INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2005, 19 (1-3): : 597 - 601
  • [47] Magnetic Field Sensing Characteristics Based on Optical Microfiber Coupler Interferometer and Magnetic Fluid
    Qin, Shangpeng
    Lu, Junyang
    Li, Minwei
    Yu, Yang
    Yang, Junbo
    Zhang, Zhenrong
    PHOTONICS, 2021, 8 (09)
  • [48] Optical and magnetic resonance studies of defects in GaN
    Glaser, ER
    ICDS-18 - PROCEEDINGS OF THE 18TH INTERNATIONAL CONFERENCE ON DEFECTS IN SEMICONDUCTORS, PTS 1-4, 1995, 196- : 9 - 16
  • [49] Loss-Based Magnetic Field Sensor Employing Hollow Core Fiber and Magnetic Fluid
    Song, Binbin
    Miao, Yinping
    Lin, Wei
    Zhang, Hao
    Liu, Bo
    Wu, Jixuan
    Liu, Haifeng
    Yan, Donglin
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2014, 26 (22) : 2283 - 2286
  • [50] Simultaneous Magnetic Field and Temperature Measurement Based on No-Core Fiber Coated With Magnetic Fluid
    Su, Geng-Hua
    Shi, Jia
    Xu, De-Gang
    Zhang, Hai-Wei
    Xu, Wei
    Wang, Yu-Ye
    Feng, Jia-Chen
    Yao, Jian-Quan
    IEEE SENSORS JOURNAL, 2016, 16 (23) : 8489 - 8493