Acceptable indoor air quality at reduced energy consumption for high-occupancy buildings with intermittent operation

被引:3
作者
Budaiwi, Ismail Mohammed [1 ]
Mohammed, Mohammed Alhaji [1 ]
机构
[1] King Fahd Univ Petr & Minerals, Coll Environm Design, Dept Architectural Engn, Dhahran, Saudi Arabia
关键词
High occupancy buildings; ventilation; indoor air quality; energy savings; intermittent occupancy; contaminant; OPTIMAL TEMPERATURE CONTROL; THERMAL COMFORT; PERSONALIZED VENTILATION; OFFICE BUILDINGS; SUPPLY-SYSTEM; FLOW; PERFORMANCE; VALIDATION; PERCEPTION; MODEL;
D O I
10.1080/00038628.2023.2199705
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In high-occupancy buildings with intermittent and short-occupancy events, occupants and their activities are the primary sources of contaminants, rendering continuous ventilation unnecessary for achieving acceptable indoor air quality (IAQ). Because the recommended ventilation rate constitutes a substantial percentage of the supply air, reducing or discontinuing ventilation during unoccupied periods saves significant energy. This study aims to assess the IAQ of high-occupancy buildings with different ventilation strategies and occupancy schemes to conserve energy using CONTAM (IAQ and ventilation analysis program) and Visual-DOE (energy analysis program). The results show that intermittently operating the ventilation 1 hour before occupancy saves 25% in the auditorium and 33% in the mosque compared to the continuous ventilation strategy. The intermittently operated strategy with ventilation 1 hour before occupancy also revealed an acceptable CO2 level (<1000ppm), while the Formaldehyde (HCHO) levels decreased with increasing ventilation rates, as humans' contribution to the HCHO concentration indoors was insignificant.
引用
收藏
页码:242 / 258
页数:17
相关论文
共 104 条
[1]  
ABCB, 2016, HDB IND AIR QUAL
[2]   Effectiveness of intermittent personalized ventilation assisting a chilled ceiling for enhanced thermal comfort and acceptable indoor air quality [J].
Al Assaad, Douaa ;
Ghali, Kamel ;
Ghaddar, Nesreen .
BUILDING AND ENVIRONMENT, 2018, 144 :9-22
[3]   Effectiveness of intermittent personalized ventilation in protecting occupant from indoor particles [J].
Al Assaad, Douaa ;
Habchi, Carine ;
Ghali, Kamel ;
Ghaddar, Nesreen .
BUILDING AND ENVIRONMENT, 2018, 128 :22-32
[4]   Analyzing the Efficiency of Introduction of the Intermittent Heating Mode [J].
Anisimova, E. ;
Shcherbak, A. .
INTERNATIONAL CONFERENCE ON CONSTRUCTION, ARCHITECTURE AND TECHNOSPHERE SAFETY (ICCATS 2017), 2017, 262
[5]  
[Anonymous], 2017, Occupational safety and health standards: Scaffolds and rope descent systems
[6]  
Apte MG., 2000, Proceedings of Healthy Buildings, V1, P133
[7]  
ASHRAE, 2013, 621 ASHRAE
[8]  
Awbi H., 2003, Ventilation of Building
[9]   Comparative study of continuous versus intermittent heating for local residential building: Case studies in Jordan [J].
Badran, Ali A. ;
Jaradat, Adnan W. ;
Bahbouh, Mustafa N. .
ENERGY CONVERSION AND MANAGEMENT, 2013, 65 :709-714
[10]   Ventilation rates in schools and pupils' performance [J].
Bako-Biro, Zs. ;
Clements-Croome, D. J. ;
Kochhar, N. ;
Awbi, H. B. ;
Williams, M. J. .
BUILDING AND ENVIRONMENT, 2012, 48 :215-223