On the depth of penetration of migrating corrosion inhibitor Haenytex Protectoseal CI into concrete

被引:1
|
作者
Tarasov, A. S. [1 ]
Khvastin, M. A. [1 ]
Gedvillo, I. A. [2 ]
Zhmakina, A. S. [2 ]
Vesely, S. S. [2 ]
Andreev, N. N. [2 ]
Chayko, M. A. [3 ]
机构
[1] MSS JSC, Vorontsovskaya Str 35, Moscow 109147, Russia
[2] Russian Acad Sci, AN Frumkin Inst Phys Chem & Electrochem, Leninsky Pr 31, Moscow 119071, Russia
[3] JSC IFKhAN, Aprelevskaya Str,65 Bldg 5,Off 1, Naro Fominsk Dist 143362, Moscow Region, Russia
关键词
corrosion of steel reinforcement in concrete; migrating inhibitors; HAENYTEX (R) Protectoseal CI; penetration depth; corrosion protection of steel reinforcement;
D O I
10.17675/2305-6894-2023-12-4-46
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Corrosion protection of steel reinforcement in concrete is an important technical task. An efficient method used to solve this problem involves the use of special corrosion inhibitors, including migrating corrosion inhibitors. HAENYTEX (R) Protectoseal CI is one of such inhibitors. It is applied to the surface of reinforced concrete structures both for additional protection in the course of building new structures and during the operation of structures once the first signs of reinforcement corrosion appear. The inhibitor migrates into concrete stone pores and, on reaching the reinforcement, stops or slows down the corrosion processes on it. The depth of inhibitor penetration into concrete stone was estimated in laboratory experiments and in full-scale tests on bridge structures, using an indicator that changes color in the presence of Protectoseal CI. It was found experimentally that upon applying onto the surface, the inhibitor penetrates into concrete to a depth of more than 15 cm. At the same time, the protective concentration of the inhibitor determined under severe model conditions (NaCl content in concrete: 3% of the binder weight) is created at a depth of at least 6-10 cm. The optimal consumption of the inhibitor for the protection of reinforced concrete structures is 0.6-0.9 L/m2.
引用
收藏
页码:2327 / 2332
页数:6
相关论文
共 50 条
  • [1] Use of UV Spectroscopy for Detecting Migrating Corrosion Inhibitor Depth in Concrete
    Miksic, Boris A.
    Shen, Ming
    Hicks, Joshua
    MATERIALS PERFORMANCE, 2013, 52 (11) : 48 - 51
  • [2] Migrating corrosion inhibitor protection of concrete
    Bjegovic, D
    Miksic, B
    MATERIALS PERFORMANCE, 1999, 38 (11) : 52 - 56
  • [3] Migrating corrosion inhibitor transporting model in cement concrete
    Liu, Zhiyong, 1600, Chinese Ceramic Society (42):
  • [4] The performance of a migrating corrosion inhibitor suitable for reinforced concrete
    Vázquez, M. (mvazquez@fi.mdp.edu.ar), 1600, Kluwer Academic Publishers (33):
  • [5] The performance of a migrating corrosion inhibitor suitable for reinforced concrete
    W. Morris
    A. Vico
    M. Vázquez
    Journal of Applied Electrochemistry, 2003, 33 : 1183 - 1189
  • [6] The performance of a migrating corrosion inhibitor suitable for reinforced concrete
    Morris, W
    Vico, A
    Vázquez, M
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2003, 33 (12) : 1183 - 1189
  • [7] Migrating corrosion inhibitor protection of steel rebar in concrete
    Bavarian, B
    Reiner, L
    MATERIALS PERFORMANCE, 2003, : 3 - 5
  • [8] On penetration of IFKhAN-80 migrating corrosion inhibitor into cement stone
    Andreev, N. N.
    Bulgakov, D. S.
    Gedvillo, I. A.
    Zhmakina, A. S.
    Vesely, S. S.
    INTERNATIONAL JOURNAL OF CORROSION AND SCALE INHIBITION, 2014, 3 (04): : 238 - 245
  • [9] Migrating corrosion inhibitor blend for reinforced concrete:: Part 1 -: Prevention of corrosion
    Elsener, B
    Büchler, M
    Stalder, F
    Böhni, H
    CORROSION, 1999, 55 (12) : 1155 - 1163
  • [10] Penetration properties and injecting conditions of corrosion inhibitor for concrete
    Wang, Xiao-Yong
    Lee, Seokhee
    Cho, Hyeongkyu
    CONSTRUCTION AND BUILDING MATERIALS, 2021, 284