Measurement Repeatability and Reproducibility of Virtual Goniometry of a Set of Acquired Images in Youths with Arthrogryposis Multiplex Congenita

被引:0
作者
Gagnon, Marianne [1 ,2 ,4 ]
Merlo, Gabriela Marino [1 ]
Dahan-Oliel, Noemi [1 ,3 ]
Veilleux, Louis -Nicolas [1 ,2 ]
机构
[1] Shriners Hosp Children Canada, Montreal, PQ, Canada
[2] McGill Univ, Dept Surg, Div Expt Surg, Montreal, PQ, Canada
[3] McGill Univ, Fac Med & Hlth Sci, Sch Phys & Occupat Therapy, Montreal, PQ, Canada
[4] 1003 Decarie Blvd, Montreal, PQ H4A 0A9, Canada
关键词
Arthrogryposis Multiplex Congenita; Joint Range of Motion; Teleassessment; Telerehabilitation; Virtual Goniometry Assessment; RELIABILITY; CHILDREN; AMYOPLASIA; TELEREHABILITATION; REHABILITATION; ERRORS; ADULTS;
D O I
暂无
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Objectives: To evaluate the intra-rater repeatability and the inter-rater reproducibility of using a virtual goniometer to measure upper and lower extremity joint range of motion (ROM) in youths with arthrogryposis multiplex congenita (AMC). Methods: Youths presenting with AMC aged 8 to 21 years old were recruited. ROM of the upper and lower limbs were assessed remotely during a teleassessment on a video-conferencing platform. Screen captures were taken and ROM were measured by two raters, two-weeks apart, using a virtual goniometer. Intraclass correlation coefficient (ICC) and associated 95% confidence interval (CI) were calculated to assess intra-and inter-rater repeatability and reproducibility. Results: Nine participants were included with a median age of 15.9 years (range: 11.3 to 20.8 years). The overall intrarater ICC was 0.997 (95% CI:0.996 to 0.997) for the first rater and 0.993 (95% CI:0.992 to 0.994) for the second rater. The inter-rater ICC ranged from 0.410 (95% CI:-0.392; 0.753) for forearm pronation to 0.998 (95% CI:0.996; 0.999) for elbow flexion. Conclusions: Results of the current study suggest that virtual goniometry is reproducible and repeatable for the ROM of most joints. Future studies should evaluate procedural reliability and validity of the proposed method for youth with complex conditions.
引用
收藏
页码:175 / 188
页数:14
相关论文
共 2 条
  • [1] A Telerehabilitation Intervention for Youths With Arthrogryposis Multiplex Congenita: Protocol for a Pilot Study
    Gagnon, Marianne
    Collins, Jessica
    Elfassy, Caroline
    Merlo, Gabriela Marino
    Marsh, Jacquelyn
    Sawatzky, Bonita
    Yap, Rita
    Hamdy, Reggie
    Veilleux, Louis-Nicolas
    Dahan-Oliel, Noemi
    JMIR RESEARCH PROTOCOLS, 2020, 9 (06):
  • [2] Repeatability and reproducibility of manual choroidal thickness measurement using Lenstar images in children before and after orthokeratology treatment
    Guo, Biyue
    Lau, Jason K.
    Cheung, Sin Wan
    Cho, Pauline
    CONTACT LENS & ANTERIOR EYE, 2022, 45 (04)