Outcomes of the Gore® Excluder® Iliac Branch Endoprosthesis Using Self Expanding or Balloon-Expandable Stent Grafts for the Internal Iliac Artery Component

被引:3
|
作者
Cortolillo, Nicholas S. [1 ]
Guerra, Andres [1 ]
Murphy, Eric [1 ]
Hoel, Andrew W. [1 ]
Eskandari, Mark K. [1 ]
Tomita, Tadaki M. [1 ]
机构
[1] Northwestern Univ, Feinberg Sch Med, Dept Surg, Div Vasc Surg, 676 North St Clair St,Suite 650, Chicago, IL 60611 USA
关键词
iliac artery; balloon-expandable stents; self-expanding stent; abdominal aortic aneurysm; endograft; endoleak; ENDOVASCULAR ANEURYSM REPAIR; AORTOILIAC ANEURYSMS; PRESERVATION; EMBOLIZATION; CONFORMABILITY; BIFURCATION; EXPERIENCE;
D O I
10.1177/15266028231169177
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: The GORE((R)) EXCLUDER (R) Iliac Branch Endoprosthesis (IBE; W.L. Gore & Associates, Flagstaff, Arizona) was developed to be used in combination with a self-expanding stent graft (SESG) for the internal iliac artery (IIA) bridging stent. Balloon-expandable stent grafts (BESGs) are an alternative for the IIA, offering advantages in sizing, device tracking, precision, and lower profile delivery. We compared the performance of SESG and BESG when used as the IIA bridging stent in patients undergoing EVAR with IBE. Methods: This is a retrospective review of consecutive patients who underwent EVAR with IBE implantation at a single center from October 2016 to May 2021. Anatomic and procedural characteristics were recorded via chart review and computed tomography (CT) postprocessing software (Vitrea((R)) v7.14). Devices were assigned to SESG vs. BESG groups based on the type of device landing into the most distal IIA segment. Analysis was performed per device to account for patients undergoing bilateral IBE. The primary endpoint was IIA patency, and secondary endpoint was IBE-related endoleak. Results: During the study period, 48 IBE devices were implanted in 41 patients (mean age 71.1 years). All IBE devices were implanted in conjunction with an infrarenal endograft. There were 24 devices in each of the self-expanding internal iliac component (SE-IIC) and balloon-expandable internal iliac component (BE-IIC) groups. The BE-IIC group had smaller diameter IIA target vessels (11.6 +/- 2.0 mm vs. 8.4 +/- 1.7 mm, p<0.001). Mean follow-up was 525 days. Loss of IIA patency occurred in 2 SESG devices (8.33%) at 73 and 180 days postprocedure, and in zero BESG devices, however, this difference was not statistically significant (p=0.16). There was 1 IBE-related endoleak requiring reintervention during the study period. A BESG device required reintervention due to Type 3 endoleak at 284 days. Conclusions: There were no significant differences in outcomes between SESG and BESG when used for the IIA bridging stent in EVAR with IBE. The BESGs were associated with using 2 IIA bridging stents and were more often deployed in smaller IIA target arteries. Retrospective study design and small sample size may limit the generalizability of our findings.
引用
收藏
页码:1227 / 1233
页数:7
相关论文
共 33 条
  • [31] Study design and rationale of the ‘Balloon-Expandable Cobalt Chromium SCUBA Stent versus Self-Expandable COMPLETE-SE Nitinol Stent for the Atherosclerotic ILIAC Arterial Disease (SENS-ILIAC Trial) Trial’: study protocol for a randomized controlled trial
    Woong Gil Choi
    Seung Woon Rha
    Cheol Ung Choi
    Eung Ju Kim
    Dong Joo Oh
    Yoon Hyung Cho
    Sang Ho Park
    Seung Jin Lee
    Ae Yong Hur
    Young Guk Ko
    Sang Min Park
    Ki Chang Kim
    Joo Han Kim
    Min Woong Kim
    Sang Min Kim
    Jang Ho Bae
    Jung Min Bong
    Won Yu Kang
    Jae Bin Seo
    Woo Yong Jung
    Jang Hyun Cho
    Do Hoi Kim
    Ji Hoon Ahn
    Soo Hyun Kim
    Ji Yong Jang
    Trials, 17
  • [32] Intravascular Ultrasound Comparison of the Self-Expanding Sideguard Stent in the Side Branch Versus a Balloon-Expandable Stent in the Main Vessel to Assess Mechanisms of Acute Lumen Gain in Bifurcation Lesions
    Ma, Shixin
    Maehara, Akiko
    Hauptmann, Karl E.
    Guagliumi, Giulio
    Valsecchi, Orazio
    Vassileva, Angelina
    Appelman, Yolande
    Sangiorgi, Giuseppe
    Prati, Francesco
    Mintz, Gary S.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (05) : 748 - 754
  • [33] Mid-Term Outcomes of the Iliac Branch Endoprosthesis with Standardized Combinations of Bridging Stent-Grafts for Endovascular Treatment of Aortoiliac Disease with or Without Co-existing Hypogastric Aneurysms (The HYPROTECT Study)
    D'Oria, Mario
    Pitoulias, Georgios
    Lepidi, Sandro
    Bellosta, Raffaello
    Reijnen, Michel M. P. J.
    Simonte, Gioele
    Pratesi, Giovanni
    Usai, Marco V.
    Gargiulo, Mauro
    Dias, Nuno
    Ferrer, Ciro
    Benedetto, Filippo
    Veraldi, Gian Franco
    Duppers, Philip
    Noya, Jorge F.
    Wiersema, Arno
    Spanos, Konstantinos
    Troisi, Nicola
    Moniaci, Diego
    Antonello, Michele
    Trimarchi, Santi
    de Vries, Jean-Paul
    Abisi, Said
    Pitoulias, Apostolos
    Taneva, Gergana T.
    Donas, Konstantinos P.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2024, 47 (12) : 1739 - 1749