A Room-Temperature Operational Alignment Magnetometer Utilizing Free-Spin Precession

被引:11
作者
Jin, Ge [1 ,2 ,3 ]
Shi, Tao [1 ,2 ,3 ]
Zhao, Yan [1 ,2 ,3 ]
Zhang, Hong [1 ,2 ,3 ]
Zou, Sheng [1 ,2 ,3 ]
机构
[1] Beihang Univ, Sch Instrument Sci & Optoelect Engn, Beijing 100191, Peoples R China
[2] Beihang Univ, Hangzhou Innovat Inst, Zhejiang Prov Key Lab Ultraweak Magnet Field Space, Hangzhou 310051, Peoples R China
[3] Hefei Natl Lab, Hefei 230088, Peoples R China
基金
中国国家自然科学基金; 北京市自然科学基金;
关键词
alignment magnetometer; free-spin precession; paraffin-coated cell; rubidium vapor; OPTICALLY PUMPED MAGNETOMETERS; MAGNETOENCEPHALOGRAPHY;
D O I
10.1002/qute.202300377
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
An alignment magnetometer based on free-spin precession (FSP) has been deployed in the geomagnetic range. A linearly polarized probe beam is utilized to create alignment in a buffer-gas-free paraffin-coated natural abundance rubidium vapor cell at room temperature exposed to a pulsed radio frequency field. Furthermore, the utilization of hyperfine-selective optical repumping employing linearly polarized beams amplifies the proportion of responsive atoms. As a consequence, this leads to a remarkable enhancement in the optical rotation signal. This paper reports measurements with a minor static magnetic field of about 1 mu T$\umu {\text{T}}$ inside a four-layer mu$\umu$-metal shield, achieving a system noise level of 0.16 pT(Hz${\text{pT\nobreakspace }}(\sqrt {{\text{Hz}}}$)-1. With a static magnetic field amplitude of 48.5 mu T$\umu {\text{T}}$ (in proximity to Earth's magnetic field), the noise level is approximate to 0.75 pT(Hz${\text{pT }}(\sqrt {{\text{Hz}}}$)-1. This manuscript introduces a breakthrough alignment magnetometry using a buffer-gas-free paraffin-coated rubidium cell. The concept of leveraging free-spin precession within geomagnetic ranges is presented, maintaining room temperature operation. This innovation paves the way for operating at room temperature within the geomagnetic range while maintaining an ultrahigh level of sensitivity.image
引用
收藏
页数:7
相关论文
共 39 条
  • [1] Nonlinear magneto-optical rotation with frequency-modulated light in the geophysical field range
    Acosta, V.
    Ledbetter, M. P.
    Rochester, S. M.
    Budker, D.
    Kimball, D. F. Jackson
    Hovde, D. C.
    Gawlik, W.
    Pustelny, S.
    Zachorowski, J.
    Yashchuk, V. V.
    [J]. PHYSICAL REVIEW A, 2006, 73 (05):
  • [2] Highly stable atomic vector magnetometer based on free spin precession
    Afach, S.
    Ban, G.
    Bison, G.
    Bodek, K.
    Chowdhuri, Z.
    Grujic, Z. D.
    Hayen, L.
    Helaine, V.
    Kasprzak, M.
    Kirch, K.
    Knowles, P.
    Koch, H. -C.
    Komposch, S.
    Kozela, A.
    Krempel, J.
    Lauss, B.
    Lefort, T.
    Lemiere, Y.
    Mtchedlishvili, A.
    Naviliat-Cuncic, O.
    Piegsa, F. M.
    Prashanth, P. N.
    Quemener, G.
    Rawlik, M.
    Ries, D.
    Roccia, S.
    Rozpedzik, D.
    Schmidt-Wellenburg, P.
    Severjins, N.
    Weis, A.
    Wursten, E.
    Wyszynski, G.
    Zejma, J.
    Zsigmond, G.
    [J]. OPTICS EXPRESS, 2015, 23 (17): : 22108 - 22115
  • [3] High-sensitivity atomic magnetometer unaffected by spin-exchange relaxation
    Allred, JC
    Lyman, RN
    Kornack, TW
    Romalis, MV
    [J]. PHYSICAL REVIEW LETTERS, 2002, 89 (13) : 130801 - 130801
  • [4] Theory of spin-exchange optical pumping of 3He and 129Xe
    Appelt, S
    Baranga, AB
    Erickson, CJ
    Romalis, MV
    Young, AR
    Happer, W
    [J]. PHYSICAL REVIEW A, 1998, 58 (02): : 1412 - 1439
  • [5] Moving magnetoencephalography towards real-world applications with a wearable system
    Boto, Elena
    Holmes, Niall
    Leggett, James
    Roberts, Gillian
    Shah, Vishal
    Meyer, Sofie S.
    Munoz, Leonardo Duque
    Mullinger, Karen J.
    Tierney, Tim M.
    Bestmann, Sven
    Barnes, Gareth R.
    Bowtell, Richard
    Brookes, Matthew J.
    [J]. NATURE, 2018, 555 (7698) : 657 - +
  • [6] A new generation of magnetoencephalography: Room temperature measurements using optically-pumped magnetometers
    Boto, Elena
    Meyer, Sofie S.
    Shah, Vishal
    Alem, Orang
    Knappe, Svenja
    Kruger, Peter
    Fromhold, T. Mark
    Lim, Mark
    Glover, Paul M.
    Morris, Peter G.
    Bowtell, Richard
    Barnes, Gareth R.
    Brookes, Matthew J.
    [J]. NEUROIMAGE, 2017, 149 : 404 - 414
  • [7] Resonant nonlinear magneto-optical effects in atoms
    Budker, D
    Gawlik, W
    Kimball, DF
    Rochester, SM
    Yashchuk, VV
    Weis, A
    [J]. REVIEWS OF MODERN PHYSICS, 2002, 74 (04) : 1153 - 1201
  • [8] Four-channel optically pumped atomic magnetometer for magnetoencephalography
    Colombo, Anthony P.
    Carter, Tony R.
    Borna, Amir
    Jau, Yuan-Yu
    Johnson, Cort N.
    Dagel, Amber L.
    Schwindt, Peter D. D.
    [J]. OPTICS EXPRESS, 2016, 24 (14): : 15403 - 15416
  • [9] Ultrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer
    Dang, H. B.
    Maloof, A. C.
    Romalis, M. V.
    [J]. APPLIED PHYSICS LETTERS, 2010, 97 (15)
  • [10] Ultra-sensitive magnetometry based on free precession of nuclear spins
    Gemmel, C.
    Heil, W.
    Karpuk, S.
    Lenz, K.
    Ludwig, Ch.
    Sobolev, Yu.
    Tullney, K.
    Burghoff, M.
    Kilian, W.
    Knappe-Grueneberg, S.
    Mueller, W.
    Schnabel, A.
    Seifert, F.
    Trahms, L.
    Baessler, St.
    [J]. EUROPEAN PHYSICAL JOURNAL D, 2010, 57 (03) : 303 - 320