Biomechanical design optimization of proximal humerus locked plates: A review

被引:3
|
作者
Zdero, Radovan [1 ]
Brzozowski, Pawel [1 ,3 ]
Schemitsch, Emil H. [1 ,2 ]
机构
[1] Victoria Hosp, Orthopaed Biomech Lab, London, ON, Canada
[2] Western Univ, Div Orthopaed Surg, London, ON, Canada
[3] Victoria Hosp, Room A6-144,800 Commissioners Rd East, London, ON N6A 5W9, Canada
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2024年 / 55卷 / 02期
关键词
Biomechanics; Optimization; Proximal humerus; Locked plates; Review; SURGICAL NECK FRACTURES; LOCKING PLATE; MEDIAL SUPPORT; INTERNAL-FIXATION; STAINLESS-STEEL; CALCAR SCREWS; IN-VITRO; BONE; STABILITY; IMPLANTS;
D O I
10.1016/j.injury.2023.111247
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Proximal humerus locked plates (PHLPs) are widely used for fracture surgery. Yet, non-union, malunion, infection, avascular necrosis, screw cut-out (i.e., perforation), fixation failure, and re-operation occur. Most biomechanical investigators compare a specific PHLP configuration to other implants like nonlocked plates, nails, wires, and arthroplasties. However, it is unknown whether the PHLP configuration is biomechanically optimal according to some well-known biomechanical criteria. Therefore, this is the first review of the systematic optimization of plate and/or screw design variables for improved PHLP biomechanical performance.Methods: The PubMed website was searched for papers using the terms "proximal humerus" or "shoulder" plus "biomechanics/biomechanical" plus "locked/locking plates". PHLP papers were included if they were (a) optimization studies that systematically varied plate and screw variables to determine their influence on PHLP's biomechanical performance; (b) focused on plate and screw variables rather than augmentation techniques (i.e., extra implants, bone struts, or cement); (c) published after the year 2000 signaling the commercial availability of locked plate technology; and (d) written in English.Results: The 41 eligible papers involved experimental testing and/or finite element modeling. Plate variables investigated by these papers were geometry, material, and/or position, while screw variables studied were number, distribution, angle, size, and/or threads. Numerical outcomes given by these papers included stiffness, strength, fracture motion, bone and implant stress, and/or the number of loading cycles to failure. But, no paper fully optimized any plate or screw variable for a PHLP by simultaneously applying four well-established biomechanical criteria: (a) allow controlled fracture motion for early callus generation; (b) reduce bone and implant stress below the material's ultimate stress to prevent failure; (c) maintain sufficient bone-plate interface stress to reduce bone resorption (i.e., stress shielding); and (d) increase the number of loading cycles before failure for a clinically beneficial lifespan (i.e., fatigue life). Finally, this review made suggestions for future work, identified clinical implications, and assessed the quality of the papers reviewed.Conclusions: Applying biomechanical optimization criteria can assist biomedical engineers in designing or evaluating PHLPs, so orthopaedic surgeons can have superior PHLP constructs for clinical use.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Evaluation of outcome of distal humerus fracture fixation by two-locked plates
    Haidarah, Abdul Fatah Abbas Mansoor
    WORLD FAMILY MEDICINE, 2022, 20 (02): : 19 - 26
  • [42] Biomechanical Contribution of Tension-Reducing Rotator Cuff Sutures in 3-Part Proximal Humerus Fractures
    Arvesen, John E.
    Gill, Stephen W.
    Sinatra, Philip M.
    Eng, Michael
    Bledsoe, Gary
    Kaar, Scott G.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2016, 30 (08) : E262 - E266
  • [43] Locking Plates With Computationally Enhanced Screw Trajectories Provide Superior Biomechanical Fixation Stability of Complex Proximal Humerus Fractures
    Mischler, Dominic
    Schader, Jana Felicitas
    Dauwe, Jan
    Tenisch, Lara
    Gueorguiev, Boyko
    Windolf, Markus
    Varga, Peter
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [44] Locking intramedullary nails versus locking plates for the treatment of proximal humerus fractures
    Gracitelli, Mauro E. C.
    Malavolta, Eduardo A.
    Assuncao, Jorge H.
    Ferreira Neto, Arnaldo A.
    Silva, Jorge S.
    Hernandez, Arnaldo Jose
    EXPERT REVIEW OF MEDICAL DEVICES, 2017, 14 (09) : 733 - 739
  • [45] A Methodology for Biomechanical Assessment of Proximal Humerus Fractures Using an Integrated Experimental and Computational Framework
    Jabran, Ali
    Ren, Lei
    Peach, Chris
    Zou, Zhenmin
    SECOND CIRP CONFERENCE ON BIOMANUFACTURING, 2016, 49 : 139 - 142
  • [46] Cement-augmented locked plate fixation proximal humerus fractures in elderly patient: a systematic review and meta-analysis
    Li, Dong-Yang
    Zhang, Kun
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [47] Biomechanical design of Less Invasive Stabilization System femoral plates: Computational evaluation of the fracture environment
    Reina-Romo, Esther
    Giraldez-Sanchez, M. A.
    Mora-Macias, J.
    Cano-Luis, P.
    Dominguez, Jaime
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2014, 228 (10) : 1043 - 1052
  • [48] Using the Greater Tuberosity as a Reference for Placement of Proximal Humerus Plates Leads to a High Rate of Calcar Screw Malposition
    Patel, Midhat
    Castaneda, Paulo
    Kisana, Haroon
    Roache, William K.
    Dehghan, Niloofar
    McKee, Michael D.
    Amini, Michael H.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2022, 36 (10) : 525 - 529
  • [49] RESULTS OF TREATMENT OF PROXIMAL HUMERUS FRACTURES USING LOCKING PLATES
    Monteiro, Gustavo Cara
    Ejnisman, Benno
    Andreoli, Carlos Vicente
    Pochini, Alberto de Castro
    Olympio, Edgler
    ACTA ORTOPEDICA BRASILEIRA, 2011, 19 (02): : 69 - 73
  • [50] Clinical Results for Minimally Invasive Locked Plating of Proximal Humerus Fractures
    Roederer, Goetz
    Erhardt, Johannes
    Graf, Michael
    Kinzl, Lothar
    Gebhard, Florian
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2010, 24 (07) : 400 - 406