Estimating follow-up CTs from geometric deformations of catheter implants in interstitial breast brachytherapy: A feasibility study using electromagnetic tracking

被引:1
|
作者
Duerrbeck, Christopher [1 ,2 ,4 ]
Schulz, Moritz [1 ,2 ]
Pflaum, Leonie [1 ,2 ,3 ]
Kallis, Karoline [1 ]
Geimer, Tobias [1 ,3 ]
Abu-Hossin, Nadin [1 ,2 ]
Strnad, Vratislav [1 ,2 ]
Maier, Andreas [3 ]
Fietkau, Rainer [1 ,2 ]
Bert, Christoph [1 ,2 ]
机构
[1] Friedrich Alexander Univ Erlangen Nurnberg FAU, Dept Radiat Oncol, Univ Klinikum Erlangen, Erlangen, Germany
[2] Comprehens Canc Ctr Erlangen EMN CCC ER EMN, Erlangen, Germany
[3] FAU, Pattern Recognit Lab, Erlangen, Germany
[4] Univ Klinikum Erlangen, Strahlenklin, Univ Str 27, D-91054 Erlangen, Germany
关键词
assurance; breast cancer; electromagnetic tracking; interstitial brachytherapy; MULTICATHETER BRACHYTHERAPY; MOTION MODEL; RECONSTRUCTION; IRRADIATION; BIOPSY; CANCER;
D O I
10.1002/mp.16659
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundElectromagnetic tracking (EMT) systems have been shown to provide valuable information on the geometry of catheter implants in breast cancer patients undergoing interstitial brachytherapy (iBT). In the context of an extended patient-specific, pre-treatment verification, EMT can play a key role in determining the potential need and, if applicable, the appropriate time for treatment adaptation. To detect dosimetric shortcomings the relative position between catheters, and target volume and critical structures must be known. Since EMT cannot provide the anatomical context and standard imaging techniques such as cone-beam CT are not yet available in most brachytherapy suites, it is not possible to detect anatomic changes on a daily or fraction basis, so the need for adaptive planning cannot be identified. PurposeThe aim of this feasibility study is to develop and evaluate a technique capable of estimating follow-up CTs at any time based on the initial treatment planning CT (PCT) and surrogate information about changes of the implant geometry from an EMT system. MethodsA deformation vector field is calculated from two different implant reconstructions acquired in treatment position through EMT, the first immediately after the PCT and the second at another time point during the course of treatment. The calculation is based on discrete displacement vectors of pairs of control and target points. These are extrapolated by means of different radial basis functions in order to cover the entire CT volume. The adequate parameters for the calculation of the deformation field were identified. By warping the PCT according to the deformation field, one obtains an estimated CT (ECT) that reflects the geometric changes. For the proof of concept, ECTs were computed for the time point of the clinical follow-up CT (FCT) that is embedded in the treatment workflow after the fourth fraction. ResultsECT and clinical FCTs of 20 patients were compared to each other quantitatively in terms of absolute Hounsfield unit differences in the planning target volume (PTV) and in a convex hull (CH) enclosing the catheters. The median differences were 31.2 and 29.5 HU for the CH and the PTV, respectively. ConclusionThe proposed ECT approach was able to approximate the "anatomy of the day" and therefore, in principle, allows a dosimetric appraisal of the treatment plan quality before each fraction. In this way, it can contribute to a more detailed patient-specific quality assurance in iBT of the breast and help to identify the timing for a potential treatment adaptation.
引用
收藏
页码:5793 / 5805
页数:13
相关论文
共 6 条
  • [1] Error detection using an electromagnetic tracking system in multi-catheter breast interstitial brachytherapy
    Masitho, Siti
    Kallis, Karoline
    Strnad, Vratislav
    Fietkau, Rainer
    Bert, Christoph
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (20)
  • [2] A Japanese prospective multi-institutional feasibility study on accelerated partial breast irradiation using interstitial brachytherapy: clinical results with a median follow-up of 26 months
    Nose, Takayuki
    Otani, Yuki
    Asahi, Shuuji
    Tsukiyama, Iwao
    Dokiya, Takushi
    Saeki, Toshiaki
    Fukuda, Ichirou
    Sekine, Hiroshi
    Shikama, Naoto
    Kumazaki, Yu
    Takahashi, Takao
    Yoshida, Ken
    Kotsuma, Tadayuki
    Masuda, Norikazu
    Yoden, Eisaku
    Nakashima, Kazutaka
    Matsumura, Taisei
    Nakagawa, Shino
    Tachiiri, Seiji
    Moriguchi, Yoshio
    Itami, Jun
    Oguchi, Masahiko
    BREAST CANCER, 2016, 23 (06) : 861 - 868
  • [3] A Japanese prospective multi-institutional feasibility study on accelerated partial breast irradiation using multicatheter interstitial brachytherapy: clinical results with a median follow-up of 60 months
    Yoshida, Ken
    Nose, Takayuki
    Otani, Yuki
    Asahi, Shuuji
    Tsukiyama, Iwao
    Dokiya, Takushi
    Saeki, Toshiaki
    Fukuda, Ichirou
    Sekine, Hiroshi
    Kumazaki, Yu
    Takahashi, Takao
    Kotsuma, Tadayuki
    Masuda, Norikazu
    Yoden, Eisaku
    Nakashima, Kazutaka
    Matsumura, Taisei
    Nakagawa, Shino
    Tachiiri, Seiji
    Moriguchi, Yoshio
    Itami, Jun
    Oguchi, Masahiko
    BREAST CANCER, 2022, 29 (04) : 636 - 644
  • [4] A Japanese prospective multi-institutional feasibility study on accelerated partial breast irradiation using interstitial brachytherapy: clinical results with a median follow-up of 26 months
    Takayuki Nose
    Yuki Otani
    Shuuji Asahi
    Iwao Tsukiyama
    Takushi Dokiya
    Toshiaki Saeki
    Ichirou Fukuda
    Hiroshi Sekine
    Naoto Shikama
    Yu Kumazaki
    Takao Takahashi
    Ken Yoshida
    Tadayuki Kotsuma
    Norikazu Masuda
    Eisaku Yoden
    Kazutaka Nakashima
    Taisei Matsumura
    Shino Nakagawa
    Seiji Tachiiri
    Yoshio Moriguchi
    Jun Itami
    Masahiko Oguchi
    Breast Cancer, 2016, 23 : 861 - 868
  • [5] A Japanese prospective multi-institutional feasibility study on accelerated partial breast irradiation using multicatheter interstitial brachytherapy: clinical results with a median follow-up of 60 months
    Ken Yoshida
    Takayuki Nose
    Yuki Otani
    Shuuji Asahi
    Iwao Tsukiyama
    Takushi Dokiya
    Toshiaki Saeki
    Ichirou Fukuda
    Hiroshi Sekine
    Yu Kumazaki
    Takao Takahashi
    Tadayuki Kotsuma
    Norikazu Masuda
    Eisaku Yoden
    Kazutaka Nakashima
    Taisei Matsumura
    Shino Nakagawa
    Seiji Tachiiri
    Yoshio Moriguchi
    Jun Itami
    Masahiko Oguchi
    Breast Cancer, 2022, 29 : 636 - 644
  • [6] Triaging subjects with palpable breast masses for biopsy, follow-up or treatment using AI applied to breast ultrasound in a low-resource setting - A feasibility study
    Mitra, Jhimli
    Ghose, Soumya
    Ginty, Fiona
    Berg, Wendie A.
    Cen, Steven
    Larsen, Linda H.
    Dauphine, Christine
    Cho, Sanghee
    Love, Susan
    Davis, Cynthia
    2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,