Dynamic performance analysis and thermal modelling of a novel two-phase spray cooled rack system for data center cooling

被引:21
作者
Liu, Pengfei [1 ]
Kandasamy, Ranjith [1 ]
Ho, Jin Yao [1 ]
Wong, Teck Neng [1 ]
Toh, Kok Chuan [1 ]
机构
[1] Nanyang Technol Univ, Sch Mech & Aerosp Engn, 50 Nanyang Ave, Singapore 639798, Singapore
基金
新加坡国家研究基金会;
关键词
Spray cooled rack; Dynamic study; Thermal modelling; Data center; Energy saving;
D O I
10.1016/j.energy.2023.126835
中图分类号
O414.1 [热力学];
学科分类号
摘要
Cooling systems in information technology (IT) equipment account for the greatest share of direct energy consumption in data centers. Conventional air-cooling schemes are thermally inefficient and energy intensive as they require large temperature difference between heat source and cooling medium. To overcome the aforementioned drawbacks of air-cooling, a "chillerless" novel spraying architecture which has the capability of performing high heat flux cooling, is highly scalable and easily adaptable by modern data centers is proposed in this paper. To demonstrate the scalability and performance of this new cooling scheme, a full-scale spray cooled rack system which has the capacity of housing up to 12 server units is developed. The dynamic performance of the spray cooled rack system under variable ambient temperature is studied. It is found that the ambient temperature strongly affects the spray cooling performances and the chamber pressure stability. A grey box model of the system is established. The newly developed model has successfully predicted the temperature variation on both the water side and spray cooling side with reasonable accuracy. Our model sets the foundation for predictive control of the chamber pressure and workload management of the spray cooling scheme for application in largescale data centers.
引用
收藏
页数:19
相关论文
共 33 条
  • [21] Performance analysis and optimization of a hybrid mechanical and free cooling system with cold water storage for a data center
    Xiang, Ke
    Tian, Zhiyong
    Zhou, Chaohui
    Luo, Yongqiang
    Wu, Wentao
    Fan, Jianhua
    Deymi-Dashtebayaz, Mahdi
    APPLIED THERMAL ENGINEERING, 2025, 267
  • [22] Investigation on the two-phase loop cooling system composed of maglev compressor and liquid pump for data centers
    Wang, Bo
    Wang, Fei
    Yang, Minghong
    Bao, Yunhao
    Geng, Xudong
    Shao, Shuangquan
    APPLIED THERMAL ENGINEERING, 2023, 218
  • [23] Study on the operation strategy of the water cooling system in the single-phase immersion cooling data center considering cooling tower performance
    Wang, Chenxu
    Yu, Hang
    Xian, Lei
    Liu, Guoqiu
    Chen, Lei
    Tao, Wen-Quan
    ENERGY AND BUILDINGS, 2024, 324
  • [24] Performance analysis of single-phase immersion cooling system of data center using FC-40 dielectric fluid
    Muneeshwaran, M.
    Lin, Yueh-Cheng
    Wang, Chi-Chuan
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2023, 145
  • [25] Full-scale Two-phase Liquid Immersion Cooing Data Center System in Tropical Environment
    Wu, Chenlong
    Tong, Wei
    Kanbur, Bans Burak
    Duan, Fei
    PROCEEDINGS OF THE 2019 EIGHTEENTH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS (ITHERM 2019), 2019, : 703 - 708
  • [26] Energy saving potential analysis of two-phase immersion cooling system with multi-mode condenser
    Zhang, Ce
    Sun, Xiaoqing
    Han, Zongwei
    Li, Xiuming
    Dong, Jiaxiang
    APPLIED THERMAL ENGINEERING, 2023, 219
  • [27] Experimental study of pump-driven chip-level two-phase cooling system for data centres
    Wang, Leixin
    Cheng, Hao
    Yang, Tongzhi
    Yuan, Weixing
    Ren, Kexian
    INDOOR AND BUILT ENVIRONMENT, 2024, 33 (01) : 57 - 73
  • [28] Development and experimental study of an independent row-based cooling system for improving thermal performance of a data center
    Cho, Jinkyun
    Woo, Jesang
    APPLIED THERMAL ENGINEERING, 2020, 169
  • [29] Comparative energy analysis of cooling energy performance between conventional and hybrid air source internet data center cooling system
    Lamptey, Nicholas Boafo
    Anka, Selorm Kwaku
    Cho, Yong
    Lee, Kwang Ho
    Choi, Jong Woong
    Choi, Jong Min
    ENERGY AND BUILDINGS, 2024, 302
  • [30] Experimental study on thermal performance of a single-phase immersion cooling unit for high-density computing power data center
    Sun, Xinshan
    Liu, Zhan
    Ji, Shenrui
    Yuan, Kaifeng
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2025, 112