Comparisons of Different Bearing Surfaces in Cementless Total Hip Arthroplasty: A Systematic Review and Bayesian Network Analysis

被引:5
作者
Zheng, Che [1 ]
Xu, Jiawen [1 ]
Wu, Liming [1 ]
Wu, Yuangang [1 ]
Liu, Yuan [1 ]
Shen, Bin [1 ,2 ]
机构
[1] Sichuan Univ, West China Hosp, Dept Orthopaed, Chengdu, Sichuan, Peoples R China
[2] Sichuan Univ, West China Hosp, Dept Orthopaed, 37 Guoxue Rd, Chengdu 610041, Peoples R China
关键词
total hip arthroplasty; bearings; metal ion level; ceramic; polyethylene; implant survival; METAL-ON-METAL; CROSS-LINKED POLYETHYLENE; RANDOMIZED CONTROLLED-TRIAL; 5-YEAR FOLLOW-UP; CHROME FEMORAL HEADS; ION LEVELS; OXIDIZED ZIRCONIUM; COBALT-CHROMIUM; CERAMIC BEARING; CONVENTIONAL POLYETHYLENE;
D O I
10.1016/j.arth.2022.10.016
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: We aimed to make comparisons of different bearing surfaces in patients after cementless total hip arthroplasty. Methods: The network meta-analysis was guided by the Preferred Reporting Items for Systematic Re-views and Meta-analysis (PRISMA) guideline. The primary outcomes were implant survival and Harris hip score (HHS). Secondary outcomes included linear wear rates and serum level of metal ions. Subgroup analyses were performed by: (1) classifying head sizes as small and large; (2) femoral heads as ceramic and metal; and (3) liners as metal, ceramic, polyethylene, highly cross-linked polyethylene (HXP), or vitamin E-infused highly cross-linked polyethylene (HXPE). A total of 64 eligible RCTs with different bearings were assessed. Overall inconsistency and heterogeneity were acceptable. Results: In the 10 years follow-up, metal-on-polythene and ceramic-on-polythene bearings with small heads showed higher risk for revisions compared with metal-on-HXP and ceramic-on-HXP bearings with small heads. Similarly, only metal or ceramic-on-polythene bearings with small heads showed inferiority in HHS compared with other bearings. Conventional polyethylene liners showed higher linear wear rates compared with HXP, HXPE, and ceramic liners at 5 and 10 years after surgery, while metal-on-metal and ceramic-on-metal bearings showed higher serum level of cobalt and chromium. Conclusion: Bearings containing HXP, HXPE, and ceramic liners showed comparable survivorship and hip function at follow-up of 5 and 10 years. Hard-on-hard bearings containing metal had higher serum level of metal ions than others. Bearings containing conventional polyethylene had worse performance in terms of implant survival, hip function, and wear rates. Level of Evidence: Level I. (c) 2022 Elsevier Inc. All rights reserved.
引用
收藏
页码:600 / 609
页数:10
相关论文
共 91 条
  • [1] Comparison of Surgical Outcomes and Implant Wear Between Ceramic-Ceramic and Ceramic-Polyethylene Articulations in Total Hip Arthroplasty
    Amanatullah, Derek F.
    Landa, Joshua
    Strauss, Eric J.
    Garino, Jonathan P.
    Kim, Sunny H.
    Di Cesare, Paul E.
    [J]. JOURNAL OF ARTHROPLASTY, 2011, 26 (06) : 72 - 77
  • [2] Metasul vs Cerasul bearings: a prospective, randomized study at a mean eighteen years
    Andeol, Quentin
    Viste, Anthony
    Desmarchelier, Romain
    Lerat, Jean-Luc
    Fessy, Michel-Henri
    [J]. INTERNATIONAL ORTHOPAEDICS, 2020, 44 (12) : 2545 - 2551
  • [3] A comparison of the effect of large and small metal-on-metal bearings in total hip arthroplasty on metal ion levels and the incidence of pseudotumour A FIVE-YEAR FOLLOW-UP OF A PREVIOUS REPORT
    Ando, W.
    Yasui, H.
    Yamamoto, K.
    Oinuma, K.
    Tokunaga, H.
    Inaba, Y.
    Kobayashi, N.
    Aihara, M.
    Nakanishi, R.
    Ohzono, K.
    [J]. BONE & JOINT JOURNAL, 2018, 100B (08) : 1018 - 1024
  • [4] Ten-year follow-up study of three alternative bearing surfaces used in total hip arthroplasty in young patients A PROSPECTIVE RANDOMISED CONTROLLED TRIAL
    Atrey, A.
    Ward, S. E.
    Khoshbin, A.
    Hussain, N.
    Bogoch, E.
    Schemitsch, E. H.
    Waddell, J. P.
    [J]. BONE & JOINT JOURNAL, 2017, 99B (12) : 1590 - 1595
  • [5] The Ideal Total Hip Replacement Bearing Surface in the Young Patient: A Prospective Randomized Trial Comparing Alumina Ceramic-On-Ceramic With Ceramic-On-Conventional Polyethylene: 15-Year Follow-Up
    Atrey, Amit
    Wolfstadt, Jesse, I
    Hussain, Nasir
    Khoshbin, Amir
    Ward, Sarah
    Shahid, Mohammad
    Schemitsch, Emil H.
    Waddell, James P.
    [J]. JOURNAL OF ARTHROPLASTY, 2018, 33 (06) : 1752 - 1756
  • [6] Alumina-on-alumina ceramic versus metal-on-highly cross-linked polyethylene bearings in total hip arthroplasty: a comparative study
    Bascarevic, Zoran
    Vukasinovic, Zoran
    Slavkovic, Nemanja
    Dulic, Borislav
    Trajkovic, Goran
    Bascarevic, Violeta
    Timotijevic, Sladjan
    [J]. INTERNATIONAL ORTHOPAEDICS, 2010, 34 (08) : 1129 - 1135
  • [7] A Randomized Trial Comparing Ceramic-on-Ceramic Bearing vs Ceramic-on-Crossfire-Polyethylene Bearing Surfaces in Total Hip Arthroplasty
    Beaupre, Lauren A.
    Al-Houkail, Amro
    Johnston, Donald William C.
    [J]. JOURNAL OF ARTHROPLASTY, 2016, 31 (06) : 1240 - 1245
  • [8] A Randomized Trial Of Ceramic-On-Ceramic Bearing Versus Ceramic-On-Crossfire-Polyethylene Bearing In Total Hip Arthroplasty: Five-Year Outcomes
    Beaupre, Lauren A.
    Manolescu, Andrei
    Johnston, D. W. C.
    [J]. JOURNAL OF ARTHROPLASTY, 2013, 28 (03) : 485 - 489
  • [9] Are Trends in Total Hip Arthroplasty Bearing Surface Continuing to Change? 2007-2015 Usage in a Large Database Cohort
    Bedard, Nicholas A.
    Burnett, Robert A.
    DeMik, David E.
    Gao, Yubo
    Liu, Steve S.
    Callaghan, John J.
    [J]. JOURNAL OF ARTHROPLASTY, 2017, 32 (12) : 3777 - 3781
  • [10] Polyethylene Wear With Ceramic and Metal Femoral Heads at 5 Years: A Randomized Controlled Trial With Radiostereometric Analysis