The isotope distribution: A rose with thorns

被引:14
作者
Claesen, Jurgen [1 ,2 ,5 ]
Rockwood, Alan [3 ]
Gorshkov, Mikhail [4 ]
Valkenborg, Dirk [2 ]
机构
[1] Vrije Univ Amsterdam, Dept Epidemiol & Data Sci, Amsterdam UMC, Epidemiol & Data Sci, Amsterdam, Netherlands
[2] Hasselt Univ, Data Sci Inst, I Biostat, Hasselt, Belgium
[3] Univ Utah, Sch Med, Dept Pathol, Salt Lake City, UT USA
[4] Russian Acad Sci, VL Talrose Inst Energy Problems Chem Phys, NN Semenov Fed Res Ctr Chem Phys, Moscow, Russia
[5] Vrije Univ Amsterdam, Epidemiol & Data Sci, De Boelelaan 1117, Amsterdam, Netherlands
关键词
coalescence; data processing; ion trap; isotope distribution; (ultra)-high-resolution mass spectrometry; RESONANCE MASS-SPECTROMETRY; SPACE-CHARGE; FINE-STRUCTURE; ION COALESCENCE; FT-ICR; ELEMENTAL COMPOSITION; MONOISOTOPIC MASSES; PEAK DISTRIBUTIONS; SPECTRAL ACCURACY; ELECTRIC-FIELD;
D O I
10.1002/mas.21820
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The isotope distribution, which reflects the number and probabilities of occurrence of different isotopologues of a molecule, can be theoretically calculated. With the current generation of (ultra)-high-resolution mass spectrometers, the isotope distribution of molecules can be measured with high sensitivity, resolution, and mass accuracy. However, the observed isotope distribution can differ substantially from the expected isotope distribution. Although differences between the observed and expected isotope distribution can complicate the analysis and interpretation of mass spectral data, they can be helpful in a number of specific applications. These applications include, yet are not limited to, the identification of peptides in proteomics, elucidation of the elemental composition of small organic molecules and metabolites, as well as wading through peaks in mass spectra of complex bioorganic mixtures such as petroleum and humus. In this review, we give a nonexhaustive overview of factors that have an impact on the observed isotope distribution, such as elemental isotope deviations, ion sampling, ion interactions, electronic noise and dephasing, centroiding, and apodization. These factors occur at different stages of obtaining the isotope distribution: during the collection of the sample, during the ionization and intake of a molecule in a mass spectrometer, during the mass separation and detection of ionized molecules, and during signal processing.
引用
收藏
页码:22 / 42
页数:21
相关论文
共 114 条
[1]   Mass spectrometry-based proteomics [J].
Aebersold, R ;
Mann, M .
NATURE, 2003, 422 (6928) :198-207
[2]   The Spontaneous Loss of Coherence Catastrophe in Fourier Transform Ion Cyclotron Resonance Mass Spectrometry [J].
Aizikov, Konstantin ;
Mathur, Raman ;
O'Connor, Peter B. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (02) :247-256
[3]  
Allwood J William, 2012, Methods Mol Biol, V860, P157, DOI 10.1007/978-1-61779-594-7_11
[4]   Recent applications of isotope analysis to forensic anthropology [J].
Bartelink, Eric J. ;
Chesson, Lesley A. .
FORENSIC SCIENCES RESEARCH, 2019, 4 (01) :29-44
[5]   CHEMICAL MASS OF CARBON IN PROTEINS [J].
BEAVIS, RC .
ANALYTICAL CHEMISTRY, 1993, 65 (04) :496-497
[6]   An algorithm to correct saturated mass spectrometry ion abundances for enhanced quantitation and mass accuracy in omic studies [J].
Bilbao, Aivett ;
Gibbons, Bryson C. ;
Slysz, Gordon W. ;
Crowell, Kevin L. ;
Monroe, Matthew E. ;
Ibrahim, Yehia M. ;
Smith, Richard D. ;
Payne, Samuel H. ;
Baker, Erin S. .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2018, 427 :91-99
[7]   Computational quality control tools for mass spectrometry proteomics [J].
Bittremieux, Wout ;
Valkenborg, Dirk ;
Martens, Lennart ;
Laukens, Kris .
PROTEOMICS, 2017, 17 (3-4)
[8]   Spectral Accuracy and Sulfur Counting Capabilities of the LTQ-FT-ICR and the LTQ-Orbitrap XL for Small Molecule Analysis [J].
Blake, Samantha L. ;
Walker, S. Hunter ;
Muddiman, David C. ;
Hinks, David ;
Beck, Keith R. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2011, 22 (12) :2269-2275
[9]   Fourier transform ion cyclotron resonance cell with dynamic harmonization of the electric field in the whole volume by shaping of the excitation and detection electrode assembly [J].
Boldin, Ivan A. ;
Nikolaev, Eugene N. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (01) :122-126
[10]   Theory of peak coalescence in Fourier transform ion cyclotron resonance mass spectrometry [J].
Boldin, Ivan A. ;
Nikolaev, Eugene N. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (19) :3213-3219